–    Carriage error    • There is something wrong with the carriage sensor        copyir.com
–    Low temp        copyir.com    • The inside of the unit is extremely cold and cannot be operated        copyir.com Use the unit in a warmer area        copyir.com While the unit cannot be operated, the received documents are temporarily stored into the memory, and will be printed out automatically when the unit warms up        copyir.com
–    Modem error    • There is something wrong with the unit’s modem        copyir.com
01    Call service 1    • Polygon motor error        copyir.com
Polygon motor inside the LSU does not rotate        copyir.com
02    Call service 2    • Laser beam error        copyir.com Replace LSU unit        copyir.com
Synchronous signal out of the LSU cannot be detected        copyir.com
03    Call service 3    • Fuser unit cannot heat up        copyir.com Replace fuser unit        copyir.com
Temperature of the fuser does not rise up to or exceed a constant temperature        copyir.com
04    Call service 4    • Fuser fan motor error        copyir.com Replace fan motor        copyir.com
Fuser FAN does not rotate or the rotation of the Fuser FAN cannot be detected normally        copyir.com
05    Call service 5    • Print motor error        copyir.com (only for DC motor)
The main DC motor does not rotate properly or the rotation detection signal (LD signal) is not
detected during motor rotation        copyir.com
06    Call service 6    • Charge unit error (An error occurred in the Charge unit including High voltage unit        copyir.com (Also the Charger went wrong        copyir.com))
Indicates that abnormal charge voltage is output from the high voltage unit        copyir.com