001    Leading edge of the recording paper fails to reach the Timing Sensor        copyir.com (1st Cassette)    Recording paper jam        copyir.com Timing Sensor abnormal        copyir.com
002    Leading edge of the recording paper fails to reach the Timing Sensor        copyir.com (2nd Cassette)    Recording paper jam        copyir.com Timing Sensor abnormal        copyir.com
007    1        copyir.com Leading edge of the recording paper fails to reach the Paper Exit Sensor        copyir.com 2        copyir.com Recording paper has not completely passed the Paper Exit Sensor        copyir.com    Recording paper jam        copyir.com Paper Exit Sensor abnormal        copyir.com
010    No recording paper        copyir.com    No recording paper or paper is not set properly        copyir.com No Paper Sensor is defective        copyir.com
011    Paper Cassette is not installed properly        copyir.com    
012    The length of the received document is over 2 meter (78        copyir.com7in)        copyir.com    
021    Thermistor is abnormal        copyir.com Fuser Control is abnormal        copyir.com Fan is abnormal        copyir.com    Defective SC PCB        copyir.com Defective Fuser Unit, Power Supply Unit        copyir.com Defective Fan        copyir.com
030    Read Point Sensor does not go ON within 10 seconds after the document starts feeding        copyir.com    Document is not set properly        copyir.com Defective Read Point Sensor        copyir.com
031    Transmitting document was longer than 2 meter (or 78        copyir.com7 in)        copyir.com    The document may jam        copyir.com Defective Read Point Sensor        copyir.com
041    Out of toner        copyir.com    No toner        copyir.com Defective Toner Sensor        copyir.com
043    Low toner        copyir.com    Toner is getting low        copyir.com Defective Toner Sensor        copyir.com
045    No Toner Cartridge        copyir.com    Toner cartridge has not been installed        copyir.com Defective Toner Sensor (Cartridge Sensor)        copyir.com
051    Printer Motor abnormal        copyir.com    Connector not properly connected        copyir.com Defective Printer Motor        copyir.com Defective SC PCB        copyir.com
054    HSYNC abnormal        copyir.com Motor abnormal        copyir.com    Defective Laser Unit        copyir.com
060    Printer Cover is open        copyir.com    Cover is not firmly closed        copyir.com Connectors are not firmly connected        copyir.com
061    ADF Door is open        copyir.com    Door is not firmly closed        copyir.com Connectors are not firmly connected        copyir.com
200    Decoding process is not completed at the end of phase C        copyir.com    Defective SC PCB        copyir.com
212    Interface error occurred between the CPU and modem        copyir.com    Modem is defective        copyir.com (SC PCB) Software problem occurred        copyir.com (SC PCB)
301    System fault        copyir.com    Software problem occurred        copyir.com (SC PCB)
331    8-minutes timer error        copyir.com (Germany only)    
390    Interface error occurred between the machine and the PC        copyir.com    Firmware update error        copyir.com GDI print error        copyir.com (Perform the operation again)
400    T1 timer (35±5 sec        copyir.com) elapsed without detecting 300 bps signal        copyir.com    Wrong number is dialed and the START button is pushed        copyir.com Telephone line is disconnected while dialing        copyir.com SC PCB (Modem) or MJR PCB are defective        copyir.com Receiver is defective        copyir.com (It may only be transmitting CED)
401    DCN was returned from receiver while transmitter is waiting for CFR or FTT        copyir.com    Your machine’s ID Number is not programmed        copyir.com Possible incompatibility or incorrect Password        copyir.com
402    DCN was returned from receiver while transmitter is waiting for NSF/DIS        copyir.com    Receiver working in non-CCITT mode only        copyir.com (Possible incompatibility)
403    Transmitter had no polling function        copyir.com    “POLLED=ON” (polling XMT ready) is not set at the transmitter        copyir.com Document to be transmitted is not placed at the transmitter        copyir.com
404    Transmitter sent NSS (or DCS) followed by TCF three times, but the receiver did not respond        copyir.com (CFR or FTT is usually returned)    Receiver is defective        copyir.com (Modem, MJR PCB, etc        copyir.com) SC PCB or MJR PCB are defective        copyir.com Receiver disconnects line during first NSS (or DCS) is transmitted        copyir.com
405    Transmitter received FTT after it transmitted TCF at 2400bps        copyir.com Received RTN after communicating at 2400 bps        copyir.com    Line quality is poor        copyir.com (TCF is damaged due to line noise) Receiver is defective        copyir.com (Modem, etc        copyir.com) SC PCB or MJR PCB are defective        copyir.com
406    XMT-Password mismatched        copyir.com RCV-Password mismatched        copyir.com Selective RCV incomplete        copyir.com    XMT, RCV password does not match        copyir.com Last 4 digits of TSI does not match with the last 4 digits of ONE-TOUCH, ABBR telephone number        copyir.com
407    Transmitter received no response after it transmitted post message, such as EOP, MPS, EOM, etc        copyir.com        copyir.com        copyir.comor received DCN        copyir.com    Receiver is defective        copyir.com (No paper, paper jamming, etc        copyir.com) Receiver ceased receiving because of excessive error        copyir.com (Line quality is poor) SC PCB (Modem) or MJR PCB are defective        copyir.com
408    Transmitter received RTN after it transmitted EOP, MPS, or EOM        copyir.com    Receiver receives data with error        copyir.com (Line quality is poor) Receiver is defective        copyir.com (Modem, etc        copyir.com) SC PCB or MJR PCB are defective        copyir.com
409    Transmitter receives PIN after it transmitted a post message, such as EOP, MPS, EOM, etc        copyir.com    Receiver receives data with error due to poor line quality, and receiving operator requests voice contact        copyir.com Receiver is defective        copyir.com (Modem, etc        copyir.com) SC PCB or MJR PCB are defective        copyir.com
410    Received DCN while waiting for post command        copyir.com (EOP, MPS, EOM, etc        copyir.com)    Interface or line is faulty        copyir.com Transmitter is defective        copyir.com
411    Received DCN after transmitting NSC        copyir.com    Transmitter is not ready for polling communication        copyir.com Password does not match between transmitter and receiver        copyir.com
412    No response within 12 seconds in NSS/DCS/MPS wait state        copyir.com (After transmitting FTT)    Transmitter is defective        copyir.com SC PCB is defective        copyir.com
414    No response received after transmitting 3rd NSC        copyir.com    Password does not match between transmitter and receiver        copyir.com Transmitter is defective        copyir.com (No original, document jam, etc        copyir.com)
415    Remote side attempted to receive message from your machine in polling communication        copyir.com    Inform the remote side that your machine does not have the polling transmission feature        copyir.com
416    Receiver did not detect post command, such as EOP, MPS, EOM, etc        copyir.com    Transmitter is defective        copyir.com Line quality is poor        copyir.com (RTC signal is distorted due to line noise) SC PCB or MJR PCB are defective        copyir.com
417    Receiver returned RTN in response to post message        copyir.com    Line quality is poor        copyir.com (There are excessive errors in received data) SC PCB or MJR PCB are defective        copyir.com
418    Receiver transmitted PIN in response to PRI-Q from transmitter        copyir.com (Transmitting operator requests voice contact)    Line quality is poor        copyir.com (There are excessive errors in received data) SC PCB or MJR PCB are defective        copyir.com
420    T1 timer (35 sec        copyir.com) elapsed without detecting 300 bps signal        copyir.com    There is wrong incoming call        copyir.com(nonfacsimile communication) Transmitter is defective        copyir.com SC PCB or MJR PCB are defective        copyir.com
421    Busy Tone is detected after sending NSF Signal        copyir.com    Remote station disconnected the line        copyir.com Wrong number is dialed        copyir.com
422    Content of NSF (or DIS) or NSC (or DTC) was invalid        copyir.com    There is an incompatibility        copyir.com
427    DCN received to NSF/CSI/DIS transmitted    The interface is incompatible        copyir.com
433            copyir.comT        copyir.com30 Protocol abnormal        copyir.com    Defective remote station        copyir.com
434    CD (response from Modem) did not turn OFF within 180 sec        copyir.com after receiver detected FLAG signal        copyir.com    Remote unit is defective        copyir.com SC PCB or MJR PCB are defective        copyir.com
436    DCN received after transmitting FTT        copyir.com    Transmitter is defective or incompatible        copyir.com Line quality is poor        copyir.com
456    Received relay transfer request or confidential document to distribute to an end receiving station or all confidential mailboxes are used        copyir.com    
459    Failed training in Phase C        copyir.com    Line quality is poor        copyir.com (Training signal is distorted due to line noise) SC PCB or MJR PCB are defective        copyir.com
490    Sum of error lines exceeded the limit (Function Parameter No        copyir.com 70) of 64 lines        copyir.com    Line quality is poor        copyir.com SC PCB or MJR PCB are defective        copyir.com
494    Interval between two EOLs was more than 10 sec        copyir.com when receiver received message data        copyir.com    Transmitter is defective        copyir.com Line quality is poor        copyir.com (EOL is damaged due to line noise) SC PCB or MJR PCB are defective        copyir.com
495    During reception, CD turned OFF or continued ON for long time        copyir.com During communication, lost loop – current        copyir.com    Line is disconnected        copyir.com Transmitter is defective        copyir.com SC PCB or MJR PCB are defective        copyir.com
496    CS of modem is not able to turn ON        copyir.com    SC PCB is defective        copyir.com
501    Remote unit does not have compatible Modem        copyir.com    
502    During reception, CD turned OFF or continued ON for long time        copyir.com During communication, lost loop – current        copyir.com    Line is disconnected        copyir.com Transmitter is defective        copyir.com SC PCB or MJR PCB are defective        copyir.com
503    CS of modem is not able to turn ON during training        copyir.com    SC PCB is defective        copyir.com Line is disconnected        copyir.com
504    Polling is rejected from the remote station        copyir.com    No polling original is set        copyir.com
505    Polling XMT is rejected        copyir.com    No polling original is set        copyir.com
540    No response after transmitting 3rd CTC or DCN received        copyir.com    Incompatible interface        copyir.com
541    No response after transmitting 3rd EOR or received DCN        copyir.com    Line is faulty        copyir.com MJR PCB abnormal        copyir.com
542    No response to the 3rd RR transmitted or received DCN        copyir.com    Remote unit is abnormal        copyir.com
543    T5 timer (60 sec        copyir.com) elapsed without MCF        copyir.com    Remote unit is abnormal        copyir.com
544    Stopped Transmission after EOR Transmission        copyir.com    Line is faulty        copyir.com MJR PCB abnormal        copyir.com
550    Timer between frames in phase C has elapsed        copyir.com    Defective remote station        copyir.com
554    Transmitted ERR after receiving EOR        copyir.com    Line is faulty        copyir.com
555    Transmitted PIN after receiving EOR        copyir.com    Line is faulty and Operator Call requested by RX side        copyir.com
570    Password or machine code did not match during remote diagnostic communication        copyir.com    
571    Remote unit did not have the remote diagnostic function        copyir.com    
580    Sub-address transmission to a unit that has their DIS bit 49 (NSF bit 155) OFF        copyir.com    Sub-address transmission to a unit that has no Sub-address function        copyir.com
581    Sub-address Password transmission to a unit that has their DIS bit 50 (NSF bit 156) OFF        copyir.com    Sub-address transmission to a unit that has no Sub-address function        copyir.com
601    ADF Door was opened during ADF transmission        copyir.com    
623    No original was in the ADF        copyir.com (Builtin dialer engaged)    Operator removed the original from the ADF after dialing was completed        copyir.com Original was not set properly in the ADF        copyir.com
630    Redial count over        copyir.com    No dial tone detected        copyir.com Sensor dial tone is not detected        copyir.com (destination dependent) Busy tone is detected        copyir.com (destination dependent) T1 timer (35±5 sec        copyir.com) elapsed without a signal from the receiver        copyir.com
631    “STOP” button was pressed during Auto Dialing        copyir.com    
634    Redial count over with no response or busy tone was not detected        copyir.com Note: U        copyir.comS        copyir.comA        copyir.com and Canadian models will redial only once if a busy tone is not detected        copyir.com    Telephone line cable is disconnected        copyir.com Wrong number is dialed        copyir.com SC or MJR PCB is abnormal        copyir.com
638    Power turned off with applicable data in memory or during communication        copyir.com    Power cord unplugged        copyir.com Power failure occurred        copyir.com
800    The machine was requested to relay a document but has no Relay Hub capability        copyir.com    
815    Mailbox is full        copyir.com    
816    “The received Polling Password did not match        copyir.com The machine does not have Confidential Comm        copyir.com capability        copyir.com”    
825    Parameter settings of the initial sending station are not properly set        copyir.com    
870    Memory overflow occurred while storing documents into memory        copyir.com    
880    File Access Error        copyir.com    
884    File Access Error        copyir.com  

اشتراک گذاری در:

پست های مرتبط

دیدگاهتان را بنویسید

نشانی ایمیل شما منتشر نخواهد شد. بخش‌های موردنیاز علامت‌گذاری شده‌اند *

جستجو در مطالب

سوالی دارید؟

برای آگاهی از راه های ارتباط با ما، بر روی دکمه زیر کلیک کنید

مطالب جدید ...

در خبرنامه ما عضو شوید