21H Faulty OHP Sensor
• It is determined that the OHP Sensor is faulty through a check made at the end of the predrive copyir.com 1 Check the PWB-A connector for proper connection and correct as necessary copyir.com 2 PC2A sensor check copyir.com PWB-A PJ12A-6 (ON) 2-D copyir.com 3 Change PWB-A copyir.com
23H Faulty Waste Toner Near Full Detection Board
• It is determined that the LED and photoreceiver are faulty through a check made when a new Drum Cartridge is detected copyir.com 1 Check the PWB-C connector for proper connection and correct as necessary copyir.com 2 Check the PWB-A connector for proper connection and correct as necessary copyir.com 3 Change the Drum Cartridge copyir.com 4 Change PWB-C copyir.com 5 Change PWB-A copyir.com
24H Faulty Fusing Thermistor Resistor
• The Heater Lamp remains ON for a predetermined consecutive period of time copyir.com
29H Faulty memory counter
• It is determined that the life counter value is faulty when the parameter chip data is read as the Power Switch is turned ON copyir.com 1 Unplug the power cord and plug it in, then turn OFF and ON the Power Switch copyir.com 2 Check Parameter Chip (PJ26) on PWB-A for proper connection and correct as necessary copyir.com 3 Change PWB-A copyir.com 4 Change Parameter Chip copyir.com
2AH Faulty memory data
• It is determined that the parameter chip data is faulty when read copyir.com 1 Unplug the power cord and plug it in, then turn OFF and ON the Power Switch copyir.com 2 Check Parameter Chip (PJ26) on PWB-A for proper connection and correct as necessary copyir.com 3 Change PWB-A copyir.com 4 Change Parameter Chip copyir.com
2BH Memory access failure
• It is determined that there is a parameter chip data access failure copyir.com 1 Unplug the power cord and plug it in, then turn OFF and ON the Power Switch copyir.com 2 Check Parameter Chip (PJ26) on PWB-A for proper connection and correct as necessary copyir.com 3 Change PWB-A copyir.com 4 Change Parameter Chip copyir.com
2CH Memory mounting failure
• Mounting of the parameter chip on the Mechanical Control Board is faulty copyir.com 1 Unplug the power cord and plug it in, then turn OFF and ON the Power Switch copyir.com 2 Check Parameter Chip (PJ26) on PWB-A for proper connection and correct as necessary copyir.com 3 Change PWB-A copyir.com 4 Change Parameter Chip copyir.com