E-000 Fuser Temperature Rising Error
Fuser Temperature does not reach 50C within 120 seconds after turning on copyir.com
E-001 Fuser Over Temperature Error
Fuser Temperature reaches over 230C copyir.com
E-002 Fuser Low Temperature Error
1 copyir.com Fuser Temperature at the time of turning on was 50 to 100C, but it does not rise up to 120C within 150 seconds after that copyir.com
2 copyir.com Fuser Temperature at the time of turning on was higher than 100C, but it does not rise up to the setting temperature within 330 seconds after that copyir.com
E-003 Fuser Temperature Abnormal Fall Error
The difference of temperature between center and side of fuser becomes 50C or more copyir.com
E-004 Fuser Temperature Abnormal Fall Error
The Lamp of fuser lights (Signal HEAT1 is “H”) to heat up the Fuser Roller in the ready condition, but even 1C of temperature rise can not be accomplished within 30 seconds copyir.com
E-010 Main Motor Error
The Main Motor Output Detection Signal (MAINM_LD) continues to be “H” for 3 seconds or longer when the Main Motor is rotating copyir.com
E-011 Fuser Motor Error
The Fuser Motor Output Detection Signal (HEATM_LD) continues to be “H” for 3 seconds or longer when the Fuser Motor is rotating copyir.com
E-012 Developer Press Motor Error
The Developer Press Sensor Signal (PRESS_S) does not change to “L” within 30 seconds after turning on copyir.com
E-020 Counter Error
The Counter Connection Detection Signal (COUNT_OPN) continues to be “L” for 1 second or longer after turning on copyir.com
E-031 Image Corona Output Error
The Image Corona Output Detection Signal (IM_LD) continues to be “L” for 1 second or longer when the Image Corona is ON copyir.com
E-032 Separation Corona Output Error
The Separation Corona Output Detection Signal (AC_LD) continues to be “L” for 1 second or longer when the Separation Corona is ON copyir.com
E-033 Transfer Corona Output Error
The Transfer Corona Output Detection Signal (TR_LD) continues to be “L” for 1 second or longer when the Transfer Corona is ON copyir.com
E-034 Bias Output Error
Bias Output Detection Signal (BIAS_LD) continues to be “L” for 1 second or longer when a specified bias is supplied to the corresponding Developer Unit components copyir.com
E-040 Cutter Error
1 copyir.com The Cutter Home Sensor Signal (MSCUT_L or MSCUT_R) does not change to “H” within 100 millisecond since the Cutter has started the operation copyir.com
2 copyir.com The Cutter Home Sensor Signal (MSCUT_L or MSCUT_R) does not change to “L” within 1 second since the Cutter has started the operation copyir.com
E-050 FPGA Error
Initialization of FPGA is failed after turning on copyir.com
E-070 Developer Unit Set Error
1 copyir.com The Connector J-253 is not connected copyir.com
2 copyir.com The Switch (MS4) is “open” condition, which detects open/close of Engine Unit or Toner Hatch copyir.com
E-080 Density Sensor Error
The default output of Density Sensor reaches less than 0 copyir.com1V or more than 1 copyir.com3V copyir.com
E-081 Density Sensor Output Error
The gap between the default output and the standard output of Density Sensor reaches less than 2V copyir.com