0030 FAX control PWB system error
Processing with the fax software was disabled due to a hardware problem copyir.com Defective PWB copyir.com
0070 FAX control PWB incompatible detection error
In the initial communication with the FAX control PWB, the normal communication command is not transmitted copyir.com Defective FAX software copyir.com Defective PWB copyir.com
0100 Backup memory device error Defective flash memory copyir.com Defective PWB copyir.com
0120 MAC address data error
The data includes an invalid MAC address Defective flash memory copyir.com Defective PWB copyir.com
0130 Backup memory read/write error (main PWB)
Mismatch between writing data and reading data successively copyir.com Defective NAND copyir.com Defective PWB copyir.com
0140 Backup memory data error (main PWB)
When the data read from NAND is abnormalities Defective flash memory copyir.com Defective PWB copyir.com
0150 Backup memory read/write error (engine PWB)
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated 5 times successively copyir.com Mismatch of reading data from 2 locations occurs 8 times successively copyir.com Mismatch between writing data and reading data occurs 8 times successively copyir.com The engine PWB EEPROM was improperly installed copyir.com Defective PWB copyir.com Defective EEPROM copyir.com
0160 Backup memory data error (engine PWB) Defective flash memory copyir.com Defective PWB copyir.com Defective EEPROM copyir.com
0170 Billing counting error
A checksum error is detected in the main and engine backup memories for the billing counters copyir.com Data in the EEPROM copyir.com Defective PWB copyir.com
0180 Machine number mismatch
Machine number of main and engine does not match copyir.com Data in the EEPROM copyir.com
0350 Panel PWB communication error (electronic volume I2C communication error) NACK is received during I2C communication – retried 5 times – rebooting command sent – retried 5 times If NACK is still received copyir.com Operation PWB copyir.com Main PWB copyir.com
0620 FAX image DIMM error
DIMM is not installed correctly copyir.com DIMM cannot be accessed copyir.com DIMM installed incorrectly copyir.com Defective PWB copyir.com
0630 DMA error
DMA transmission of image data does not complete within the specified period of time copyir.com Poor contact in the connector terminals copyir.com Defective PWB copyir.com
0640 Hard disk error
The hard disk cannot be accessed copyir.com Defective connector cable or poor contact in the connector copyir.com Defective hard disk copyir.com Defective PWB copyir.com
0650 FAX image DIMM check error
Improper DIMM is installed copyir.com DIMM installed incorrectly copyir.com DIMM of another machine is installed copyir.com Defective PWB copyir.com
0660 Hard disk encryption key error EEPROM copyir.com HDD copyir.com Main PWB
0670 Hard disk overwriting erasure error HDD copyir.com Main PWB copyir.com
0800 Image processing error
The JAM100 fee counter is continuously generated copyir.com Defective main PWB copyir.com
0830 FAX control PWB flash program area checksum error
A checksum error occurred with the program of the FAX control PWB copyir.com Defective FAX software copyir.com Defective PWB copyir.com
0840 Faults of RTC
The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed copyir.com The battery is disconnected from the main PWB copyir.com Defective PWB copyir.com
0870 FAX control PWB to main PWB high capacity data transfer error
High-capacity data transfer between the FAX control PWB and the main PWB of the machine was not normally performed even if the data transfer was retried the specified times copyir.com Improper installation FAX control PWB copyir.com HDD copyir.com Defective PWB copyir.com
0920 Fax file system error
The backup data is not retained for file system abnormality of flash memory of the FAX control PWB copyir.com Defective PWB copyir.com
0980 24 V power down detect
24V disconnection signal is detected for 1 copyir.com5 seconds copyir.com Defective power source PWB copyir.com
1010 Lift motor 1 error
After cassette 1 is inserted, the lift sensor 1 does not turn on within 15 s copyir.com This error is detected five times successively copyir.com Defective bottom plate elevation mechanism in the cassette copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of the lift motor copyir.com Defective lift motor copyir.com Defective PWB copyir.com
1020 Lift motor 2 error
After cassette 2 is inserted, PF lift sensor 2 does not turn on within 15s copyir.com This error is detected five times successively copyir.com Defective bottom plate elevation mechanism in the cassette copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of the PF lift motor 1 copyir.com Defective lift motor copyir.com Defective PWB copyir.com
1030 PF lift motor 1 error (paper feeder)
After cassette 3 is inserted, PF lift sensor 1 does not turn on within 15 s copyir.com This error is detected five times successively copyir.com Defective bottom plate elevation mechanism in the cassette copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of the PF lift motor 1 copyir.com Defective PF lift motor 1 copyir.com Defective PWB copyir.com
1040 PF lift motor 2 error (paper feeder)
After cassette 4 is inserted, PF lift sensor 2 does not turn on within 15 s copyir.com This error is detected five times successively copyir.com Defective bottom plate elevation mechanism in the cassette copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system of the PF lift motor 2 copyir.com Defective PF lift motor 2 copyir.com Defective PWB copyir.com
1100 PF lift motor 1 error (large capacity feeder)
After cassette 3 is inserted, PF lift sensor 1 does not turn on within 23 s copyir.com This error is detected 5 times successively copyir.com (Time to detect is 2 seconds at the second time and later copyir.com) During driving the motor, the lift overcurrent protective monitor signal is detected for 1s or more 5 times successively copyir.com However, the first 1 s after PF lift motor 1 is turned on is excluded from detection copyir.com PF Lift motor1 copyir.com PF Lift sensor1 copyir.com PF main PWB
1110 PF lift motor 2 error (large capacity feeder)
After cassette 4 is inserted, PF lift sensor 2 does not turn on within 23 s copyir.com This error is detected 5 times successively copyir.com (Time to detect is 2 seconds at the second time and later copyir.com) During driving the motor, the lift overcurrent protective monitor signal is detected for 1s or more 5 times successively copyir.com However, the first 1 s after PF lift motor 2 is turned on is excluded from detection copyir.com Paper feeder lift base elevating mechanism copyir.com PF Lift motor 2 copyir.com PF Lift sensor2 copyir.com PF main PWB
1800 Paper feeder communication error
A communication error is detected 10 times in succession Improper installation of the paper feeder copyir.com Defective connector cable or poor contact of the connector copyir.com Defective PWB copyir.com
1900 Paper feeder EEPROM error
When writing the data, the write data and the read data is not continuously in agreement 4 times Defective PWB copyir.com Device damage of EEPROM copyir.com
2101 Developer motor K steadystate error
The rated speed signal detected the stability OFF continuously for 1 s after the developer motor K stabilizes copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system copyir.com Defective motor copyir.com Defective PWB copyir.com
2102 Developer motor YCM steady-state error
The rated speed signal detected the stability OFF continuously for 1 s after the developer motor YCM stabilizes copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system copyir.com
2111 Developer motor K startup error
Developer motor K is not stabilized within 3 s since the motor is activated copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system copyir.com Defective motor copyir.com Defective PWB copyir.com
2112 Developer motor YCM startup error
Developer motor YCM is not stabilized within 3 s since the motor is activated copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system copyir.com Defective motor copyir.com Defective PWB copyir.com
2201 Drum motor K steady-state error
The rated speed signal detected the stability OFF continuously for 1 s after the drum motor K stabilizes copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system copyir.com Defective motor copyir.com Defective PWB copyir.com
2202 Drum motor YCM steadystate error
The rated speed signal detected the stability OFFcontinuously for 1 s after the drum motor YCM stabilizes copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system copyir.com Defective motor copyir.com Defective PWB copyir.com
2211 Drum motor K startup error
Drum motor K is not stabilized within 3 s since the motor is activated copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system copyir.com Defective motor copyir.com Defective PWB copyir.com
2212 Drum motor YCM startup error
Drum motor YCM is not stabilized within 3 s since the motor is activated copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system copyir.com Defective motor copyir.com Defective PWB copyir.com
2300 Fuser motor steady-state error
The rated speed signal detected the stability OFF continuously for 1 s after the fuser motor stabilizes copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system copyir.com Defective motor copyir.com Defective PWB copyir.com
2310 Fuser motor startup error
Fuser motor is not stabilized within 3 s since the motor is activated copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system copyir.com Defective motor copyir.com Defective PWB copyir.com
2500 Conveying motor 2 steadystate error
The rated speed signal detected the stability OFF continuously for 1 s after the conveying motor 2 stabilizes copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system copyir.com Defective motor copyir.com Defective PWB copyir.com
2510 Conveying motor 2 startup error
Conveying motor 2 is not stabilized within 2 s since the motor is activated copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system copyir.com Defective motor copyir.com Defective PWB copyir.com
2550 Conveying motor 1 steadystate error
The rated speed signal detected the stability OFF continuously for 1 s after the conveying motor 1 stabilizes copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system copyir.com Defective motor copyir.com Defective PWB copyir.com
2560 Conveying motor 1 startup error
Conveying motor 1 is not stabilized within 2 s since the motor is activated copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system copyir.com Defective motor copyir.com Defective PWB copyir.com
2600 PF drive motor error (paper feeder)
When the PF drive motor is driven, error signal is detected continuously for 1 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system copyir.com Defective motor copyir.com Defective PWB copyir.com
2610 PF paper feed motor error (bulk paper feeder)
When the PF paper feed motor is driven, error signal is detected continuously for 1 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system copyir.com Defective motor copyir.com Defective PWB copyir.com
2700 TC belt motor error
When the TC belt motor is driven, error signal is detected continuously for 3 s copyir.coms Defective drive transmission system copyir.com Defective PWB copyir.com
3100 ISU home position error
ON/OFF of the HP sensor doesn’t change after a prescribed pulse passes from power supply ON copyir.com The scanner mirror frame is being locked after setup copyir.com Scanner motor copyir.com Home position sensor copyir.com Defective PWB copyir.com
3210 CIS lamp error
When input value at the time of CIS illumination does not exceed the threshold value between 5 s copyir.com CIS copyir.com Defective PWB copyir.com
3220 LED error Defective connector cable or poor contact in the connector copyir.com Defective LED PWB copyir.com Defective PWB copyir.com
3300 Optical system (AGC) error
After AGC, correct input is not obtained at CCD copyir.com¬ Defective connector cable or poor contact in the connector copyir.com Defective LED PWB or CCD PWB copyir.com Defective PWB copyir.com
3310 CIS AGC error After AGC, correct input is not obtained at CIS copyir.com CIS copyir.com DPSHD PWB copyir.com
3500 Communication error
A wrong read-back value copyir.com Defective connector cable or poor contact in the connector copyir.com Defective CCD PWB copyir.com Defective PWB copyir.com
3600 Scanner sequence error Defective main PWB or engine PWB copyir.com
3700 Scanner device error CCD connector inserted incorrectly copyir.com
3800 AFE error
When writing the data, read and write data does not match 3 times in succession copyir.com Defective ISC PWB copyir.com
3900 Backup memory read/write error (ISC PWB)
Read and write data does not match copyir.com Defective backup memory or PWB copyir.com
4001 Polygon motor (K) steadystate error
The rated speed signal detected the stability OFF continuously for 1 s after the polygon motor (K) stabilizes copyir.com Defective connector cable or poor contact in the connector copyir.com Defective motor copyir.com Defective PWB copyir.com
4002 Polygon motor (C) steadystate error
The rated speed signal detected the stability OFF continuously for 1 s after the polygon motor (C) stabilizes copyir.com Defective connector cable or poor contact in the connector copyir.com Defective motor copyir.com Defective PWB copyir.com
4003 Polygon motor (M) steadystate error
The rated speed signal detected the stability OFF continuously for 1 s after the polygon motor (M) stabilizes copyir.com Defective connector cable or poor contact in the connector copyir.com Defective motor copyir.com Defective PWB copyir.comv
4004 Polygon motor (Y) steadystate error
The rated speed signal detected the stability OFF continuously for 1 s after the polygon motor (Y) stabilizes copyir.com Defective connector cable or poor contact in the connector copyir.com Defective motor copyir.com Defective PWB copyir.com
4011 Polygon motor (K) startup error
Polygon motor (K) is not stabilized within 10 s since the motor is activated copyir.com Defective connector cable or poor contact in the connector copyir.com Defective motor copyir.com Defective PWB copyir.com
4012 Polygon motor (C) startup error
Polygon motor (C) is not stabilized within 10 s since the motor is activated copyir.com Defective connector cable or poor contact in the connector copyir.com Defective motor copyir.com Defective PWB copyir.com
4013 Polygon motor (M) startup error
Polygon motor (M) is not stabilized within 10 s since the motor is activated copyir.com Defective connector cable or poor contact in the connector copyir.com Defective motor copyir.com Defective PWB copyir.com
4014 Polygon motor (Y) startup error
Polygon motor (Y) is not stabilized within 10 s since the motor is activated copyir.com Defective connector cable or poor contact in the connector copyir.com Defective motor copyir.com Defective PWB copyir.com
4101 BD initialization problem (K)
BD is not detected within two seconds after the polygon motor stabilizes copyir.com Defective connector cable or poor contact in the connector copyir.com Defective APCPWB copyir.com Defective BDPWB copyir.com Defective PWB copyir.com
4102 BD initialization problem (C)
BD is not detected within two seconds after the polygon motor stabilizes copyir.com Defective connector cable or poor contact in the connector copyir.com Defective APCPWB copyir.com Defective BDPWB copyir.com Defective PWB copyir.com
4103 BD initialization problem (M)
BD is not detected within two seconds after the polygon motor stabilizes copyir.com Defective connector cable or poor contact in the connector copyir.com Defective APCPWB copyir.com Defective BDPWB copyir.com Defective PWB copyir.com
4104 BD initialization problem (Y)
BD is not detected within two seconds after the polygon motor stabilizes copyir.com Defective connector cable or poor contact in the connector copyir.com Defective APCPWB copyir.com Defective BDPWB copyir.com Defective PWB copyir.com
4201 BD steady-state error K
The BD signal is not detected copyir.com PD PWB K (LSU) copyir.com Engine PWB
4202 BD steady-state error C
The BD signal is not detected copyir.com PD PWB C (LSU) copyir.com Engine PWB
4203 BD steady-state error M
The BD signal is not detected copyir.com PD PWB M (LSU) copyir.com Engine PWB
4204 BD steady-state error Y
The BD signal is not detected copyir.com PD PWB Y (LSU) copyir.com Engine PWB
4600 LSU cleaning motor error
When the LSU cleaning motor is driven, an error signal is detected continuously for 2 s copyir.com Defective connector cable or poor contact in the connector copyir.com Defective drive transmission system copyir.com Defective motor copyir.com Defective PWB copyir.com
6000 Broken fuser heater wire
Fuser thermistor 2 does not reach 80° C/176 °F even after20 s during warming up copyir.com The detected temperature of fuser thermistor2 does not reach the specified temperature (ready indication temperature) for 200 s in warming up after reached to 80° C/176 °F copyir.com Defective connector cable or poor contact in the connector copyir.com Deformed connector pin copyir.com Fuser thermostat triggered copyir.com Broken fuser heater wire copyir.com Defective PWB copyir.com
6020 Abnormally high fuser thermistor 2 (center) temperature
The fuser thermistor 2 detects a temperature higher than 240°C/464°F continuously for 1 s Deformed connector pin copyir.com Shorted fuser thermistor copyir.com Defective PWB copyir.com
6030 Fuser thermistor 2 (center) break error
A/D value of the fuser thermistor 2 exceeds 1010 bit continuously for 1 s during warming up copyir.com Defective connector cable or poor contact in the connector copyir.com Deformed connector pin copyir.com Defective fuser thermistor copyir.com Defective PWB copyir.com
6040 NC sensor error Deformed connector pin copyir.com Shorted fuser thermistor copyir.com Defective PWB copyir.com
6050 Abnormally low fuser thermistor 2 (center) temperature
The fuser temperature lower than 100 °C/212 °F is detected continuously for 1 s during printing copyir.com Deformed connector pin copyir.com Defective fuser thermistor copyir.com Defective fuser heater copyir.com Defective PWB copyir.com
6120 Abnormally high fuser thermistor 3 (press roller) temperature
The fuser temperature exceeds 200 °C/392 °F for 1 s copyir.com Deformed connector pin copyir.com Defective fuser thermistor copyir.com Defective PWB copyir.com
6130 Fuser thermistor 3 (press roller) break error
Fuser thermistor 3 detects a temperature of -14 °C/6 copyir.com8 °F copyir.com Fuser thermistor 3 does not reach 30° C/86 °F even after60 s during warming up copyir.com Defective connector cable or poor contact in the connector copyir.com Deformed connector pin copyir.com Defective fuser thermistor copyir.com Defective PWB copyir.com
6150 Abnormally low fuser thermistor 3 (press roller) temperature
The fuser temperature lower than 30 °C/86 °F is detected continuously for 1 s copyir.com Deformed connector pin copyir.com Defective fuser thermistor copyir.com Defective fuser heater copyir.com Defective PWB copyir.com
6200 Broken fuser edge heater wire
Fuser thermistor 1 does not reach 50° C/122 °F even after20 s during warming up copyir.com The detected temperature of fuser thermistor1 does not reach the specified temperature (ready indication temperature) for 60 s in warming up after reaching 50° C/122 °F copyir.com Defective connector cable or poor contact in the connector copyir.com Deformed connector pin copyir.com Fuser thermostat triggered copyir.com Broken fuser heater wire copyir.com Defective PWB copyir.com
6220 Abnormally high fuser thermistor 1 (edge) temperature
The fuser temperature exceeds 240 °C/464 °F for 1 s copyir.com Deformed connector pin copyir.com Defective cooling fan motor copyir.com Defective fuser thermistor copyir.com Defective PWB copyir.com
6230 Fuser thermistor 1 (edge) break error
During warming up a hearter, fuser thermistor 2 detects a temperature of 100 °C/212 °F or higher and, fuser thermistor 1 detects a temperature of 37 °C/99 °F or lower copyir.com Defective connector cable or poor contact in the connector copyir.com Deformed connector pin copyir.com Defective fuser thermistor copyir.com Defective PWB copyir.com
6250 Abnormally low fuser thermistor 1 (edge) temperature
The fuser temperature lower than 80 °C/176 °F is detected continuously for 1 s during printing copyir.com Deformed connector pin copyir.com Defective fuser thermistor copyir.com Defective fuser heater copyir.com Defective PWB copyir.com
6410 Fuser unit type mismatch problem
Absence of the fuser unit is detected Fuser unit connector inserted incorrectly copyir.com Different type of the fuser unit is installed copyir.com
6600 Belt rotation error
The belt was detected to stop for 2 s continuously during motor remote is on copyir.com Defective fuser motor copyir.com Defective IH belt copyir.com Defective IH PWB copyir.com Defective PWB copyir.com
6710 CPU thermal runaway (IHPWB) Defective PWB copyir.com
6720 Belt rotation error (IHPWB) Defective PWB copyir.com Defective fuser motor copyir.comPWB) copyir.com Defective fuser unit copyir.com
6730 Abnormally high IGBT1 temperature (IHPWB) Defective PWB copyir.com Defective cooling fan motor copyir.com
6740 Abnormally high IGBT2 temperature (IHPWB) Defective PWB copyir.com Defective cooling fan motor copyir.com
6750 Abnormally output overcurrent (IHPWB) Defective PWB copyir.com Defective fuser unit copyir.com
6760 Abnormally AC input overcurrent (IHPWB) Defective PWB copyir.com
6770 Abnormally low electric power (IHPWB) Defective connector cable or poor contact in the connector copyir.com Defective PWB copyir.com
6930 IH related cooling fan motor error
The alarm signal was detected for 5 seconds continuously during operation copyir.com Defective connector cable or poor contact in the connector copyir.com
6950 IH CPU communication error
A communication error is detected 3 times in succession copyir.com Defective connector cable or poor contact in the connector copyir.com Defective PWB copyir.com
6990 Fuser unit type mismatch problem
Absence of the fuser unit is detected copyir.com Defective PWB copyir.com
7101 Toner sensor K error
The sensor outputs are for 5 seconds, 23 or less, or 248 or more copyir.com Defective Developer unit copyir.com Defective PWB copyir.com
7102 Toner sensor C error
The sensor outputs are for 5 seconds, 23 or less, or 248 or more copyir.com Defective Developer unit copyir.com Defective PWB copyir.com
7103 Toner sensor M error
The sensor outputs are for 5 seconds, 23 or less, or 248 or more copyir.com Defective Developer unit copyir.com Defective PWB copyir.com
7104 Toner sensor Y error
The sensor outputs are for 5 seconds, 23 or less, or 248 or more copyir.com Defective Developer unit copyir.com Defective PWB copyir.com
7401 Developer unit K type mismatch error
Absence of the developer unit K is detected copyir.com Defective connector cable or poor contact in the connector copyir.com Different type of the developer unit is installed copyir.com
7402 Developer unit C type mismatch error
Absence of the developer unit C is detected copyir.com Defective connector cable or poor contact in the connector copyir.com Different type of the developer unit is installed copyir.com
7403 Developer unit M type mismatch error
Absence of the developer unit M is detected copyir.com Defective connector cable or poor contact in the connector copyir.com Different type of the developer unit is installed copyir.com
7404 Developer unit Y type mismatch error
Absence of the developer unit Y is detected copyir.com Defective connector cable or poor contact in the connector copyir.com Different type of the developer unit is installed copyir.com
7411 Drum unit K type mismatch problem
Absence of the drum unit K is detected copyir.com Drum unit connector inserted incorrectly copyir.com Different type of the drum unit is installed copyir.com
7412 Drum unit C type mismatch problem
Absence of the drum unit C is detected copyir.com Drum unit connector inserted incorrectly copyir.com Different type of the drum unit is installed copyir.com
7413 Drum unit M type mismatch problem
Absence of the drum unit M is detected copyir.com Drum unit connector inserted incorrectly copyir.com Different type of the drum unit is installed copyir.com
7414 Drum unit Y type mismatch problem
Absence of the drum unit Y is detected copyir.com?? Drum unit connector inserted incorrectly copyir.com Different type of the drum unit is installed copyir.com
7420 Transfer belt unit type mismatch problem
Absence of the transfer belt unit is detected copyir.com Transfer belt unit connector inserted incorrectly copyir.com Different type of the transfer belt unit is installed copyir.com
7601 ID sensor 1 (front) error Defective ID sensor copyir.com Defective PWB copyir.com
7602 ID sensor 2 (rear) error Defective ID sensor copyir.com Defective PWB copyir.com
7611 ID sensor (K) density error
When the concentration in a bias calibration is unusual copyir.com Defective ID sensor copyir.com Defective PWB copyir.com
7612 ID sensor (C) density error
When the concentration in a bias calibration is unusual copyir.com Defective ID sensor copyir.com Defective PWB copyir.com
7613 ID sensor (M) density error
When the concentration in a bias calibration is unusual copyir.com Defective ID sensor copyir.com Defective PWB copyir.com
7614 ID sensor (Y) density error
When the concentration in a bias calibration is unusual copyir.com Defective ID sensor copyir.com Defective PWB copyir.com
7620 ID sensor timing error
Color registration correction was failed copyir.com Defective ID sensor copyir.com Defective PWB copyir.com
7800 Broken external thermistor wire
The external thermistor delivers 0 copyir.com3V or more copyir.com Defective connector cable or poor contact in the connector copyir.com Defective temperature sensor copyir.com Defective PWB copyir.com
7810 Short-circuited external thermistor wire
external thermistor delivers 3V or more copyir.com Defective connector cable or poor contact in the connector copyir.com Defective temperature sensor copyir.com Defective PWB copyir.com
7901 Drum unit K EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively copyir.com Mismatch of reading data from two locations occurs eight times successively copyir.com Mismatch between writing data and reading data occurs eight times successively copyir.com Poor contact in the connector terminals copyir.com Defective drum PWB copyir.com Defective PWB copyir.com
7902 Drum unit C EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively copyir.com Mismatch of reading data from two locations occurs eight times successively copyir.com Mismatch between writing data and reading data occurs eight times successively copyir.com Poor contact in the connector terminals copyir.com Defective drum PWB copyir.com Defective PWB copyir.com
7903 Drum unit M EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively copyir.com Mismatch of reading data from two locations occurs eight times successively copyir.com Mismatch between writing data and reading data occurs eight times successively copyir.com Poor contact in the connector terminals copyir.com Defective drum PWB copyir.com Defective PWB copyir.com
7904 Drum unit Y EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively copyir.com Mismatch of reading data from two locations occurs eight times successively copyir.com Mismatch between writing data and reading data occurs eight times successively copyir.com Poor contact in the connector terminals copyir.com Defective drum PWB copyir.com Defective PWB copyir.com
7911 Developer unit K EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively copyir.com Mismatch of reading data from two locations occurs eight times successively copyir.com Mismatch between writing data and reading data occurs eight times successively copyir.com Defective developer PWB copyir.com Defective PWB copyir.com
7912 Developer unit C EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively copyir.com Mismatch of reading data from two locations occurs eight times successively copyir.com Mismatch between writing data and reading data occurs eight times successively copyir.com Poor contact in the connector terminals copyir.com Defective developer PWB copyir.com Defective PWB copyir.com
7913 Developer unit M EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively copyir.com Mismatch of reading data from two locations occurs eight times successively copyir.com Mismatch between writing data and reading data occurs eight times successively copyir.com Poor contact in the connector terminals copyir.com Defective developer PWB copyir.com Defective PWB copyir.com
7914 Developer unit Y EEPROM error
No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively copyir.com Mismatch of reading data from two locations occurs eight times successively copyir.com Mismatch between writing data and reading data occurs eight times successively copyir.com Poor contact in the connector terminals copyir.com Defective developer PWB copyir.com copyir.com Defective PWB copyir.com
8010 Punch motor 1 error
When the punch motor is driven, punch home position sensor does not turn on within 200 ms copyir.com Punch motor copyir.com Punch home position sensor copyir.com Punch PWB copyir.com DF main PWB copyir.com
8020 Punch motor 2 error
Home position is not obtained in 3 s after home position is initialized or in standby copyir.com Punch motor copyir.com Punch PWB copyir.com DF main PWB copyir.com
8030 Punch motor 3 error
Home position does not turn from On to Off in 50 ms after home position has been initialized copyir.como Punch motor copyir.com Punch PWB copyir.com DF main PWB
8090 DF paddle motor error
When the DF paddle motor is driven, DF paddle sensor does not turn on within 1 s copyir.com DF paddle motor copyir.com DF paddle sensor copyir.com DF main PWB copyir.com
8100 DF eject release motor error
When the DF eject release motor is driven, DF bundle discharge sensor does not turn on within 1 s copyir.com DF eject release motor DF bundle discharge unit sensor copyir.com DF bundle discharge unit sensor copyir.com DF main PWB copyir.com
8140 DF tray motor error 1
When the main tray has ascended, DF tray sensor 1 or DF tray upper surface sensor does not turn on within 20 s copyir.com DF tray motor copyir.com DF tray sensor 1 DF tray upper surface sensor copyir.com DF main PWB copyir.com
8150 DF tray motor error 2
When the main tray has descended, DF tray sensor 1 or DF tray upper surface sensor does not turn off within 5 s copyir.com DF tray motor copyir.com DF tray sensor 1 DF tray upper surface sensor copyir.com DF main PWB
8160 DF tray motor error 3
When the main tray has descended, DF tray sensor 3 does not turn on within 20 s copyir.com DF tray motor copyir.com DF tray sensor 4 copyir.com DF main PWB copyir.com
8170 DF side registration motor 1 error 1
When initial operation, DF side registration sensor 1 does not turn on within 3 s copyir.com DF side registration motor 1 copyir.com DF side registration sensor 1 copyir.com DF main PWB copyir.com
8180 DF side registration motor 1 error 2
JAM6810 ( jam in front of width alignment) is detected twice copyir.com DF side registration motor 1 copyir.com DF side registration sensor 1 copyir.com DF main PWB
8190 DF side registration motor 2 error 1
When initial operation, DF side registration sensor 2 does not turn on within 3 s copyir.com DF side registration motor 2 copyir.com DF side registration sensor 2 copyir.com DF main PWB copyir.com
8200 DF side registration motor 2 error 2
JAM6910 ( jam in rear of width alignment) is detected twice copyir.com20 s DF side registration motor 2 copyir.com DF side registration sensor 2 copyir.com DF main PWB copyir.com
8210 DF slide motor error
When initial operation, DF staple sensor does not turn on within 3 s copyir.com DF slide motor copyir.com DF staple sensor copyir.com DF main PWB copyir.com
8230 DF staple motor error 1
Staple JAM (DF) has been detected twice in a row copyir.com (The second JAM detection condition fullfilled with the home position did not detected in 600 ms after the motor was driven copyir.com) DF staple motor copyir.com DF staple sensor copyir.com DF main PWB
8240 DF staple motor error 2
Staple JAM (DF) has been detected twice in a row copyir.com (The second JAM detection condition fullfilled with a lock detection signal maintained 1 V for 500 ms continuously, while the stapler motor was driven copyir.com) DF staple motor copyir.com DF main PWB
8260 DF middle motor error
When the DF middle motor is driven, DF middle sensor does not turn on within 1s copyir.com DF middle motor copyir.com DF middle sensor copyir.com DF main PWB copyir.com
8410 Punch slide motor error 1
The punch slide sensor won’t turn On when home position has been moved by 30 mm copyir.com Punch slide motor copyir.com Punch slide sensor copyir.com Punch PWB copyir.com DF main PWB copyir.com
8420 Punch slide motor error 2
In detection of paper edges, the paper edge cannot be detected in 30 mm move copyir.com Punch slide motor copyir.com Punch paper edge sensor 1,2 copyir.com Punch PWB copyir.com DF main PWB
8430 Punch unit communication error
Communication with the punch unit is not possible copyir.com Punch PWB copyir.com DF main PWB copyir.com
8800 Document finisher main program error
Document finisher main program error at power up copyir.com DF main PWB copyir.com Engine PWB copyir.com
8900 Document finisher backup error
Read and write data does not match 3 times in succession copyir.com DF main PWB
8990 Backup memory data problem (document finisher)
When one of the existence of a finisher or a bridge is not detected copyir.com Defective connector cable or poor contact in the connector copyir.com Defective power cord copyir.com EEPROM installed incorrectly copyir.com Defective finisher main PWB copyir.com
9000 Document processor communication error
A communication error is detected 10 times in succession copyir.com Defective connector cable or poor contact in the connector copyir.com Defective PWB copyir.com
9010 Coin vender communication error
A communication error from coin vender is detected 10 times in succession copyir.com U206 setting copyir.com Coin vender control PWB copyir.com Engine PWB
9040 DP lift motor going up error
When the DP lift motor is driven, DP lift sensor 1 does not turn on within 1500 pulse copyir.com (Three recovery times copyir.com) The above has been detected 5 times copyir.com * The number of detection should be weighted with one for the rise at job start and two for the irregular rise during transpoting copyir.com The accumulated number must be cleared at completion of a normal rise copyir.com The default threshold is 5 copyir.com DP lift motor copyir.com DP lift sensor 1 copyir.com DP Main PWB copyir.com
9050 DP lift motor going down error
When the DP lift motor is driven, DP lift sensor 2 does not turn on within 1500 pulse copyir.com (Three recovery times copyir.com) The above has been detected 5 times copyir.com DP lift motor copyir.com DP lift sensor 2 copyir.com DP main PWB
9060 DP EEPROM error
Mismatch of reading data from two locations occurs 3 times successively copyir.com Mismatch between writing data and reading data occurs 3 times successively copyir.com DP main PWB copyir.com Device damage of EEPROM copyir.com
9070 Communication error between DP and SHD
A communication error is detected copyir.com DP SHD PWB
9080 LED fault detection
A block is existent below a peak which was obtained by activating the LEDs in the four CIS blocks at power on, which is less than 80hex copyir.com DP CIS copyir.com DP SHD PWB
9100 Coin vender control PWB error
Communication error has been detected at the coin mec of the coin vender control PWB copyir.com Defective coin vender control PWB copyir.com
9110 Coin vender error
Communication error has been detected in connection with the coin mec and the rejector copyir.com Rejector installed incorrectly copyir.com Defective rejector copyir.com
9120 Sensor error in coin vender change (Yen 10)
Change is empty despite change is enough copyir.com Coin jam in the change tube copyir.com Poor contact in the connector copyir.com Defective change empty sensor copyir.com Defective coin vender control PWB copyir.com
9130 Sensor error in coin vender change (Yen 50)
Change is empty despite change is enough copyir.com Coin jam in the change tube copyir.com Poor contact in the connector copyir.com Defective change empty sensor copyir.com Defective coin vender control PWB copyir.com
9140 Sensor error in coin vender change (Yen 100)
Change is empty despite change is enough copyir.com Coin jam in the change tube copyir.com Poor contact in the connector copyir.com Defective change empty sensor copyir.com Defective coin vender control PWB copyir.com
9150 Sensor error in coin vender change (Yen 500)
Change is empty despite change is enough copyir.com Coin jam in the change tube copyir.com Poor contact in the connector copyir.com Defective change empty sensor copyir.com Defective coin vender control PWB copyir.com
9160 Coin vender pay-out error
Coin is paid out despite the pay-out motor is determined not active copyir.com Defective pay-out motor copyir.com
9170 Coin vender pay-out sensor error
Coin is paid out despite the pay-out motor is determined not active copyir.comtor copyir.com Change jam at the pay-out copyir.com Defective pay-out motor copyir.com Defective pay-out sensor copyir.com
9500 ISC PWB error A Main PWB copyir.com ISC PWB copyir.com
9510 ISC PWB error B Main PWB copyir.com DP SHD PWB
9520 ISC PWB error C Main PWB copyir.com ISC PWB
9530 Machine number backup error C Device error
9540 Machine number backup error D Data error
9550 Machine number backup error E Operation error
F000 Communication error between main PWB and operation PWB Main PWB
F010 copyir.com copyir.com copyir.com F013 Main PWB checksum error Defective main PWB copyir.com
F020 copyir.com copyir.com copyir.com F023 System memory error
Controller detection error Defective main PWB copyir.com
F040 Communication error
between Main PWB and Print engine Main PWB copyir.com Engine PWB copyir.com HDD
F041 Communication error
between Main PWB and Scanner engine Main PWB copyir.com ISC PWB
F050 Print engine ROM checksum error Engine software copyir.com Engine PWB
F051 Scanner engine ROM checksum error Scanner software copyir.com ISC PWB