سرویس مانوئل های ریکو آفیشو ریکو آفشیو Ricoh Aficio 1075SP ۲۶ آبان ۷۷۳ · ۵۲ دقیقه مطالعه ایرادات ریکو براساس کد می باشد شرکت کپی ایران در نظر داردتمامی سرویس منالها و رفع ایرادادت را در اختیار شما عزیزان قرار دهد 101 Exposure Lamp Error At trigger on, the lamp was not detected on(کپی ایران ) • Exposure lamp defective • Lamp regulator defective • Lamp regulator harness damaged, disconnected • Dirty standard white plate • Scanner mirror dirty or out of position • Lens dirty, out of position • SBU board defective 120 Scanner home position error 1 The scanner HP sensor does not detect the on condition during initialization or copying(کپی ایران ) • BCU, SDRB (Scanner Driver Board) defective • Scanner motor defective • Harness between BCU, SDRB, scanner motor disconnected(کپی ایران ) • Scanner HP sensor defective(کپی ایران ) • Harness between scanner HP sensor and BCU disconnected(کپی ایران ) • Scanner wire, timing belt, pulley, carriage installed incorrectly(کپی ایران ) 121 Scanner home position error 2 The scanner HP sensor does not detect the off condition during initialization or copying(کپی ایران ) • BCU, SDRB (Scanner Driver Board) defective • Scanner motor defective • Harness between BCU, SDRB, scanner motor disconnected • Scanner HP sensor defective • Harness between scanner HP sensor and BCU disconnected • Scanner wire, timing belt, pulley, carriage installed incorrectly(کپی ایران ) 122 Scanner home position error 3 The scanner home position sensor does not detect the on condition during original scanning(کپی ایران ) • BCU, SDRB (Scanner Driver Board) defective • Scanner motor defective • Harness between BCU, SDRB, scanner motor disconnected • Scanner HP sensor defective • Harness between scanner HP sensor and BCU disconnected • Scanner wire, timing belt, pulley, carriage installed incorrectly 123 Scanner home position error 4 The scanner home position sensor does not detect the off condition during original scanning(کپی ایران ) • BCU, SDRB (Scanner Driver Board) defective • Scanner motor defective • Harness between BCU, SDRB, scanner motor disconnected • Scanner HP sensor defective • Harness between scanner HP sensor and BCU disconnected • Scanner wire, timing belt, pulley, carriage installed incorrectly(کپی ایران ) 143 SBU auto adjust error Automatic adjustment of the SBU fails when the machine is switched on(کپی ایران ) • Exposure lamp defective • Exposure lamp regulator defective • Harness between exposure lamp and lamp regulator is disconnected • White plate installed incorrectly or is dirty • Scanning mirrors of the exposure unit are dirty or out of position • SBU board defective • VIB board defective(کپی ایران ) • Harness between SBU, VIB disconnected • Harness between VIB, BCU disconnected 144 SBU transmission error After the SBU switches on, the BCU detects one of the following conditions on the SBU: • 1 s after power on, the SYDI signal does not go high, even after 1 retry(کپی ایران ) • 1 s after power on, the SYDI signal goes high, but the SBU ID could not be read after 3 attempts(کپی ایران ) • SBU defective • VIB defective • Harness (40-pin shielded) between the SBU, VIB is disconnected • Harness (shielded cable) between the VIB, BCU is disconnected 165 Copy data security unit error B828 The copy data security option is installed by not operating correctly(کپی ایران ) • Copy data security card corrupted • The board is not installed or the board is defective • IPU board defective 181 CIS lamp abnormal After the CIS lamp trigger goes on, the CIS lamp is not detected on(کپی ایران ) Detecting the lamp on or off determines the peak white level value for shading correction(کپی ایران ) (If the peak level is determined to be below a certain level, the CIS lamp is judged to be off(کپی ایران )) • CIS lamp defective • CIS power supply board defective • CIS lamp regulator defective • Harness between lamp and lamp regulator is disconnected(کپی ایران ) • Harness between CIS, ADF is disconnected • CIS exposure glass dirty(کپی ایران ) • White roller dirty or installed incorrectly • CIS unit defective 183 CIS auto adjust error Automatic adjustment of the CIS unit failed(کپی ایران ) • CIS unit defective • CIS exposure glass dirty • White roller dirty or installed incorrectly 184 CIS transmission error When the CIS is powered on, the ADF detects one of the following abnormal conditions on the CIS unit: • The SOUT signal does not go high within 1 s after power on(کپی ایران ) • The SOUT signal goes high within 1 s after power on, but the SBU ID cannot be read after 3 attempts(کپی ایران ) • CIS unit defective • Harness between the CIS, ADF is disconnected 202 Polygon mirror motor error 1: Timeout at ON The polygon mirror motor unit did not enter “Ready” status within 20 sec(کپی ایران ) after the motor was turned on, or within 20 sec(کپی ایران ) after the speed of rotation was changed(کپی ایران ) • The polygon mirror motor PCB connector is loose, broken, or defective • Polygon mirror motor PCB defective • Polygon mirror motor defective • IPU defective 203 Polygon mirror motor error 2: Timeout at OFF The polygon mirror motor did not leave “Ready” within 3 sec(کپی ایران ) after the motor was switched off(کپی ایران ) (The XSCRDY signal did not go HIGH (inactive) within 3 sec(کپی ایران )) • The polygon mirror motor PCB connector is loose, broken, or defective • Polygon mirror motor PCB defective • Polygon mirror motor defective • IPU defective 204 Polygon mirror motor error 3: XSCRDY signal error The polygon mirror motor “Ready” signal went inactive (HIGH) while the motor was operating at normal speed, even though the motor was neither switched off nor was there a request for a change in speed(کپی ایران ) • Electrical oise interference on the line with the motor signals • Polygon mirror motor PCB connector loose, broken, defective • Polygon mirror motor PCB defective • Polygon mirror motor defective 205 Polygon mirror motor error 4: Unstable timeout The “Ready” signal (XSCRDY) was detected as unstable for more than 20 sec(کپی ایران ) while the polygon mirror motor was operating at normal speed(کپی ایران ) • Electrical noise on the line with the motor signals • Polygon mirror motor PCB connector loose, broken, defective • Polygon mirror motor PCB defective • IPU defective 220 Laser synchronization detection error The 1st laser synchronization detection unit could not detect the line synchronization signal (DETP0) within 500 ms while the polygon mirror motor was operating at normal speed(کپی ایران ) Note: The unit polls for the signal every 50 ms(کپی ایران ) This SC is issued after the 10th attempt fails to detect the signal(کپی ایران ) • Laser synchronization board connector loose, broken, defective • Laser synchronization detection board is not installed correctly (out of alignment) • Laser synchronization board defective • IPU defective 300 Charge corona output error The feedback voltage from the charge corona unit is detected too high 9 times • Charge corona power pack defective • Charge corona harness disconnected • Poor charge corona unit connection 303 Charge corona grid leak When the high voltage is output to the corona grid, feedback voltage exceeds the prescribed value 9 times(کپی ایران ) • Charge corona power pack defective • Charge corona harness disconnected • Poor charge corona unit connection 304 Charge grid circuit open When high voltage goes to the corona grid, feedback voltage is more than the set value 9 times(کپی ایران ) This feedback voltage is used to update PWM for output control(کپی ایران ) • Charge corona unit defective or disconnected • Charge corona harness defective • Charge corona power pack is defective(کپی ایران ) 305 Charge corona wire cleaner error 1 The charge cleaner pad does not arrive at the home position: • Motor locked within 4 s after switching on, or does not lock within 30 s(کپی ایران ) • Motor locked within 10 s after reversing, or does not lock within 30 s(کپی ایران ) • Charge corona wire cleaner motor defective • Motor driver defective 306 Charge corona wire cleaner error 2 Charge coronal motor is disconnected(کپی ایران ) (The current at the charge corona motor is detected less than 83 mA(کپی ایران )) • Charge corona wire cleaner motor connector is defective, connected 310 Potential sensor calibration error 1 During drum potential sensor calibration, the drum potential sensor output voltage does not meet specification when test voltages (– 100V, –800V) are applied to the drum(کپی ایران ) • Potential sensor defective • Potential sensor harness disconnected • Potential sensor connector defective or disconnected • IOB defective • OPC connector defective • Development power pack defecti 311 Potential sensor calibration error 2 During drum potential sensor calibration, the drum potential sensor output voltage does not meet specification when test voltages (– 100V, –800V) are applied to the drum(کپی ایران ) • Potential sensor defective • Potential sensor harness disconnected • Potential sensor connector defective or disconnected • IOB defective • OPC connector defective • Development power pack defective 312 Potential sensor calibration error 3 During drum potential sensor calibration when adjusting the drum potential (VD), the drum potential sensor detects VD higher than VG (grid voltage)(کپی ایران ) -or- When adjusting VD (drum surface potential of black areas after exposure), even after 5 adjustments of VG (charge corona grid potential), VD could not be set in the target range (– 800±10 + VL + 130V) • Potential sensor defective • Potential sensor harness disconnected • Potential sensor connector defective or disconnected • IOB defective • OPC connector defective • Development power pack defective • Charge corona unit worn out, dirty 314 Potential sensor calibration error 4 During drum potential sensor calibration when adjusting the drum potential (VH) for LD power adjustment, the first time the VH pattern is made, the drum potential sensor detects that VH is more than 500V: VH > |–500 + VL + 130| V • Potential sensor defective • Potential sensor harness disconnected • Potential sensor connector defective or disconnected • IOB defective • OPC connector defective • LD defective 315 Potential sensor calibration error 5 During drum potential sensor calibration, when –100V is applied to the drum, the output value is out of the prescribed range • Potential sensor defective • Potential sensor harness disconnected • Potential sensor connector defective or disconnected • IOB defective • OPC connector defective • Development power pack defectiv 316 Potential sensor calibration error 6 During drum potential sensor calibration, when –800V is applied to the drum, the output value is out of the prescribed range(کپی ایران ) • Potential sensor defective • Potential sensor harness disconnected • Potential sensor connector defective or disconnected • IOB defective • OPC connector defective • Development power pack defective 317 Potential sensor calibration error 7 During drum potential sensor calibration, when VL is adjusted, the pattern surface potential VL pattern is not within range 0V ~ –400V(کپی ایران ) (VL is the potential after exposing a white pattern(کپی ایران )) • Potential sensor defective • Potential sensor harness disconnected • Potential sensor connector defective or disconnected • IOB defective • OPC connector defective • Charge corona power pack defective • Development power pack defective 321 F-GATE error The laser writing signal (F-GATE) for the IPU does not go LOW within 60 s(کپی ایران ) • BICU board defective • PCI bus between controller board, BICU board defective 322 Laser synchronization detector error After the polygon motor reaches standard rotation speed and the LD unit fires for 500 ms, the laser synchronization detector does not generate a signal • Harness between detector and I/F disconnected or damaged • Detector is installed incorrectly • Detector board is defective • IPU board defective 335 Polygon mirror motor error 1 The ready signal does not go low within 20 s after the polygon mirror motor turns on or changes speed(کپی ایران ) • Harness between I/F and polygon motor disconnected or defective • Polygon motor or polygon motor driver defective • IPU board defective 336 Polygon mirror motor error 2 The ready signal does not go high within 20 s after the polygonal mirror motor turns off(کپی ایران ) • Harness between I/F and polygon motor disconnected or defective • Polygon motor or polygon motor driver defective • IPU board defective 337 Polygonal mirror motor error 3 The XSCRDY signal goes high while the polygon mirror motor turns on, even though there was no request to either turn off the motor or change the motor speed(کپی ایران ) • Noise on the line where the polygon ready signal (XSCRDY) is transmitted(کپی ایران ) • Harness between the polygon motor and I/F disconnected or defective(کپی ایران ) • Polygon motor or polygon motor driver defective 338 Polygonal mirror motor error 4 While the polygon motor is rotating, the XSCRDY signal goes high during exposure • Noise on the linef where the polygon ready signal (XSCRDY) is transmitted(کپی ایران ) • Harness between the polygon motor and I/F disconnected or defective(کپی ایران ) • Polygon motor or polygon motor driver defective • IPU board defective 340 TD sensor output error TD sensor output voltage (Vt), measured during each copy cycle, is detected 10 times at one of the following levels: Vt = 0(کپی ایران )5 volts or lower Vt = 4(کپی ایران )0 volts or higher • TD sensor defective • TD sensor harness disconnected • TD sensor connector disconnected or defective • IOB defective • Toner bottle motor defective Note: When the TD sensor is defective, the toner supply is controlled using pixel count and the ID sensor(کپی ایران ) 341 TD sensor adjustment error 1 During the TD sensor auto adjustment, the TD sensor output voltage (Vt) is 2(کپی ایران )5 volts or higher even though the control voltage is set to the minimum value (PWM = 0)(کپی ایران ) When this error occurs, SP2-906-1 reads 0(کپی ایران )00V(کپی ایران ) Note: This SC is released only after correct adjustment of the TD sensor has been achieved(کپی ایران ) Switching the machine off and on will cancel the SC display, but does not release ID sensor toner supply(کپی ایران ) • TD sensor defective • TD sensor harness disconnected • TD sensor connector disconnected or defective • IOB defective • Toner bottle motor defective Note: When the TD sensor is defective, the toner supply is controlled using pixel count and the ID sensor(کپی ایران ) 342 TD sensor adjustment error 2 During the TD sensor auto adjustment, the TD sensor output voltage (Vt) does not enter the target range (3(کپی ایران )0 ± 0(کپی ایران )1V) within 20 s(کپی ایران ) When this error occurs, the display of SP2-906-1 reads 0(کپی ایران )00V(کپی ایران ) Note: This SC is released only after correct adjustment of the TD sensor has been achieved(کپی ایران ) Switching the machine off and on will cancel the SC display, but does not release ID sensor toner supply(کپی ایران ) • TD sensor defective • TD sensor harness disconnected • TD sensor connector disconnected or defective • IOB defective 345 Development output abnormal The high voltage applied to the development unit is detected 10 times higher than the upper limit (45%) of PWM(کپی ایران ) • Development power pack defective • Development bias leak due to poor connection, defective connector 350 ID sensor error 1 One of the following ID sensor output voltages was detected twice consecutively when checking the ID sensor pattern(کپی ایران ) Vsp (کپی ایران ) 2(کپی ایران )5V Vsg < 2(کپی ایران )5 Vsp = 0V Vsg = 0 • ID sensor defective • ID sensor harness disconnected • ID sensor connector defective • IOB defective • ID sensor pattern not written correctly • Incorrect image density • Charge power pack defective • ID sensor dirty 351 ID sensor error 2 The ID sensor output voltage is 5(کپی ایران )0V and the PWM signal input to the ID sensor is 0 when checking the ID sensor pattern(کپی ایران ) • ID sensor defective • ID sensor harness disconnected • ID sensor connector defective • IOB defective • ID sensor pattern not written correctly • Incorrect image density • Charge power pack defective • ID sensor dirty 352 ID sensor error 3 For 2 s during the ID sensor pattern check, the ID sensor pattern edge voltage is not 2(کپی ایران )5V or the pattern edge is not detected within 800 ms(کپی ایران ) • ID sensor defective • ID sensor harness disconnected • ID sensor connector defective • IOB defective • ID sensor pattern not written correctly • Incorrect image density • Charge power pack defective • ID sensor dirty 353 ID sensor error 4 One of the following ID sensor output voltages is detected at ID sensor initialization(کپی ایران ) (کپی ایران ) Vsg < 4(کپی ایران )0V when the maximum PWM input (255) is applied to the ID sensor(کپی ایران ) (کپی ایران ) Vsg (کپی ایران ) 4(کپی ایران )0V when the minimum PWM input (0) is applied to the ID sensor(کپی ایران ) • ID sensor defective • ID sensor harness disconnected • ID sensor connector defective • IOB defective • ID sensor pattern not written correctly • Incorrect image density • Charge power pack defective • ID sensor dirty 354 ID sensor error 5 Vsg falls out of the adjustment target (4(کپی ایران )0 ± 0(کپی ایران )2V) during Vsg checking • ID sensor defective • ID sensor harness disconnected • ID sensor connector defective • IOB defective • ID sensor pattern not written correctly • Incorrect image density • Charge power pack defective • ID sensor dirty 355 ID sensor error 6 The Vp value, which measures the reflectivity of the ID sensor pattern, was not in the range of –70V to –400V(کپی ایران ) • Potential sensor defective • Potential sensor harness defective • Potential sensor disconnected • IOB defective • OPC unit connector defective • Charge corona power pack defective • Charge corona wire dirty, broken 401 Transfer output abnormal When the transfer is output, the feedback voltage remains higher than 4V for 60 ms(کپی ایران ) • Transfer power pack defective • Transfer current terminal, transfer power pack disconnected, damaged connector 402 Transfer output abnormal release detection When the transfer is output, there is hardly any feedback voltage within 60 ms even with application of 24% PWM(کپی ایران ) • Transfer power pack defective • Transfer unit harness disconnected • Transfer connector loose, defective 430 Quenching lamp error At the completion of auto process control initialization, the potential of the drum surface detected by the potential sensor is more than –400V, the prescribed value(کپی ایران ) • Quenching lamp defective • Quenching lamp harness disconnected • Quenching lamp connector loose, defective 440 Main motor lock The main motor lock signal remains low for 2 seconds while the main motor is on(کپی ایران ) • Drive mechanism overloaded • Motor driver board defective 441 Development motor lock The development motor lock signal remains high for 2 seconds while the development motor is on(کپی ایران ) • Drive mechanism overloaded due to toner clumping in the wasted toner path • Motor driver board defective 490 Main fan error The main fan motor lock signal goes high for 5 s while the fan is on(کپی ایران ) • Fan motor overloaded due to obstruction • Fan connector disconnected 495 Toner recycling unit error Encoder pulse does not change for 3 s after the main motor switches on(کپی ایران ) • Waste toner transport has stopped due to motor overload • Toner end sensor detective, disconnected 496 Toner collection bottle errorThe toner collection bottle set switch remains off when the front door is closed(کپی ایران ) • No toner collection bottle set • Poor connection of the switch connector 497 Toner collection motor error The toner collection motor connector set signal remains off for 1 s(کپی ایران ) • Toner pump motor defective • Motor connector loose, disconnected 501 Tray 1 lift malfunction • The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate(کپی ایران ) • When the tray lowers, the tray lift sensor does not go off within 1(کپی ایران )5 sec(کپی ایران ) • Tray overload detected when the tray is set(کپی ایران ) • The lower limit sensor of the LCT does not detect the lower limit within 10 sec(کپی ایران ) • Tray lift motor defective, disconnected • Paper or other obstacle trapped between tray and motor • Pick-up solenoid disconnected, blocked by an obstacle • Too much paper loaded in tray Note (B246) • At first, the machine displays a message asking the operator to reset the tray(کپی ایران ) • This SC will not display until the operator has pulled the tray out and pushed it in 3 times(کپی ایران ) • If the operator cycles the machine off/on before the 3rd opening and closing of the tray, the 3-count is reset(کپی ایران ) 502 Tray 2 lift malfunction • The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate(کپی ایران ) • When the tray lowers, the tray lift sensor does not go off within 1(کپی ایران )5 sec(کپی ایران ) • Tray overload detected when the tray is set(کپی ایران ) • Tray lift motor defective or disconnected • Paper or other obstacle trapped between tray and motor • Pick-up solenoid disconnected or blocked by an obstacle • Too much paper loaded in tray Note (B246) • At first, the machine displays a message asking the operator to reset the tray(کپی ایران ) • This SC will not display until the operator has pulled the tray out and pushed it in 3 times(کپی ایران ) • If the operator cycles the machine off/on before the 3rd opening and closing of the tray, the 3-count is reset(کپی ایران ) 503 Tray 3 lift malfunction • The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate(کپی ایران ) • When the tray lowers, the tray lift sensor does not go off within 1(کپی ایران )5 sec(کپی ایران ) • Tray overload detected when the tray is set(کپی ایران ) • Tray lift motor defective or disconnected • Paper or other obstacle trapped between tray and motor • Pick-up solenoid disconnected or blocked by an obstacle • Too much paper loaded in tray Note (B246) • At first, the machine displays a message asking the operator to reset the tray(کپی ایران ) • This SC will not display until the operator has pulled the tray out and pushed it in 3 times(کپی ایران ) • If the operator cycles the machine off/on before the 3rd opening and closing of the tray, the 3-count is reset(کپی ایران ) 504 Tray 4 lift malfunction • The lift sensor is not activated within 10 seconds after the tray lift motor starts lifting the bottom plate(کپی ایران ) • When the tray lowers, the tray lift sensor does not go off within 1(کپی ایران )5 sec(کپی ایران ) • Tray overload detected when the tray is set • Tray lift motor defective or disconnected • Paper or other obstacle trapped between tray and motor • Pick-up solenoid disconnected or blocked by an obstacle • Too much paper loaded in tray Note (B246) • At first, the machine displays a message asking the operator to reset the tray(کپی ایران ) • This SC will not display until the operator has pulled the tray out and pushed it in 3 times(کپی ایران ) • If the operator cycles the machine off/on before the 3rd opening and closing of the tray, the 3-count is reset(کپی ایران ) 507 LCT feed motor malfunction One of the following conditions is detected: • The LD signal from the feed motor is detected abnormal for 50 ms after the motor switches on(کپی ایران ) • At power on, the motor is detected loose or disconnected • Feed motor defective • Feed motor connector disconnected • Obstacle interfering with mechanical movement of motor(کپی ایران ) 510 LCT tray malfunction One of the following conditions is detected: • When the bottom plate is lifted, the upper limit sensor does not come on for 18 s(کپی ایران ) • When the bottom plate is lowered, the lower limit sensor does not come on for 18 s(کپی ایران ) • After lift begins, the upper limit sensor does not switch on before the pick-up solenoid switches on(کپی ایران ) • The paper end sensor switches on during lift and the upper limit sensor does not switch on for 2(کپی ایران )5 s, and a message prompts user to reset paper(کپی ایران ) • Tray lift motor defective or connector disconnected • Lift sensor defective or disconnected • Pick-up solenoid defective or disconnected • Paper end sensor defective 515 Tandem rear fence motor error One of the conditions is detected: • The return sensor does not switch on within 10 sec(کپی ایران ) after the rear fence motor switches on(کپی ایران ) • The HP sensor does not switch on 10 sec(کپی ایران ) after the rear fence motor switches on(کپی ایران ) • The HP sensor and return sensor switch on at the same time(کپی ایران ) • Rear fence motor defective or poor connection • Paper or other obstacle interfering with operation of the sensors • Paper or other obstacle trapped between tray and motor • Motor mechanical overload due to obstruction • Return sensor or HP sensor defective or dirty Note (B246) • This problem will not issue the SC code on the operation panel(کپی ایران ) • The machine will prompt the operator to reset tray by opening and closing it(کپی ایران ) • If the problem persists, the machine will display again and the tray cannot be used(کپی ایران ) 520 Duplex jogger motor error 1 When the jogger fence moves to the home position, the jogger HP sensor does not turn on even if the jogger fence motor has moved the jogger fence 153(کپی ایران )5 mm • Paper or other obstacle has jammed mechanism • Sensor connector disconnected or defective • Sensor defective 521 Duplex jogger motor error 2 When the jogger fence moves from the home position, the jogger fence HP sensor does not turn off even if the jogger motor has moved the jogger fence 153(کپی ایران )5 mm(کپی ایران ) • Paper or other obstacle has jammed mechanism • Sensor connector disconnected or defective • Sensor defective 531 Fusing exit motor error The PLL lock signal was low for 2 seconds during motor operation(کپی ایران ) • Motor lock caused by physical overload • Motor drive PCB defective 541 Fusing thermistor open The fusing temperature detected by the center thermistor was below 0°C for 7 sec(کپی ایران ) • Thermistor open • Thermistor connector defective • Thermistor damaged, or out of position • Fusing temperature –15% less than the standard input voltage 542 Fusing temperature warm-up error One of the following occurred: • After power on, or after closing the front door, the hot roller does not reach the 100°C control temperature within 25 s(کپی ایران ) • 5 sec(کپی ایران ) after temperature rise started, temperature remained below 21°C after 5 samplings(کپی ایران ) • Fusing unit did not attain reload temperature within 48 sec(کپی ایران ) of the start of fusing temperature control(کپی ایران ) • Fusing lamp disconnected • Thermistor warped, out of position • Thermostat not operating 543 Fusing lamp overheat error 1 (software) Central thermistor detected a temperature of 240°C at the center of the hot roller(کپی ایران ) Fusing temperature control software error • PSU defective • IOB defective • BICU defective 544 Fusing lamp overheat error 1 (hardware) The central thermistor or an end thermistor detected a temperature of 250°C on the hot roller(کپی ایران ) • PSU defective • IOB defective • BICU defective 545 Fusing lamp overheat error 2 After hot roller reaches warmup temperature, the fusing lamps remained on at full capacity for 11 samplings (1(کپی ایران )8 sec(کپی ایران ) duration) while the hot roller was not rotating(کپی ایران ) • Thermistor damaged, or out of position • Fusing lamp disconnected 547 Zero cross signal malfunction One of the following conditions is detected 10 times: • When the main switch is on, the frequency measured by the number of zero cross signals for 500 ms is larger than 66Hz or smaller than 45 Hz(کپی ایران ) • The interval between one zero cross signal and the next is 7(کپی ایران )5 ms or shorter 3 times consecutively for 500 ms(کپی ایران ) • Noise on the ac power line 550 Fusing Web End Web end detected 5 times within 500 ms and web motor continues to rotate 40 s(کپی ایران ) If web end is detected for another 500 ms, then the SC is logged(کپی ایران ) • Web end (requires replacement) • Web end sensor defective Note: After replacing the web with a new one, reset SP1902 001 to “0” to release SC550(کپی ایران ) 551 Fusing thermistor error 1 The end thermistor (contact type) was less than 0C (32F) for more than 7 seconds(کپی ایران ) • Thermistor disconnected • Thermistor connector defective 552 Fusing thermistor error 2 The end thermistor (contact type) could not detect: • 100°C 25 seconds after the start of the warmup cycle(کپی ایران ) • A change in temperature more than than 16 degrees for 5 seconds(کپی ایران ) • The reload temperature with 56 seconds after the start of the fusing temperature control cycle(کپی ایران ) • Fusing lamp disconnected • Thermistor bent, damaged • Thermistor position incorrect 553 Fusing thermistor error 3 The end thermistor (contact type) was at 240°C (464°F) for more than 1 second(کپی ایران ) The temperature is read 10 times every sec(کپی ایران ) (at 0(کپی ایران )1 sec(کپی ایران ) intervals)(کپی ایران ) • PSU defective • IOB control board defective • BICU control board defective 555 Fusing lamp error After the start of the warmup cycle, a fusing lamp was at full power for 1(کپی ایران )8 seconds but the hot roller did not turn(کپی ایران ) • Thermistor bent, out of position • Fusing lamp disconnected • Circuit breaker opened 557 Zero cross signal error High frequency noise was detected on the power line(کپی ایران ) • No action required(کپی ایران ) The SC code is logged and the operation of the machine is not affected(کپی ایران ) 559 Fusing jam: 3 counts At the fusing exit sensor the paper was detected late for three pulse counts (lag error), and SP1159 was on(کپی ایران ) This SC only occurs if SP1159 is on, and a jam occurred in the fusing unit for three consecutive sheets of paper(کپی ایران ) Remove the paper that is jammed in the fusing unit(کپی ایران ) Then make sure that the fusing unit is clean and has no obstacles in the paper feed path(کپی ایران ) 569 Fusing pressure release motor error During copying, the HP sensor could not detect the actuator, tried again 3 times and could not detect(کپی ایران ) • Motor lock because of too much load • Motor driver defective • HP sensor defective, disconnected, connector defective, harness damaged 590 Toner collection motor error The toner collection motor sensor output does not change for 3 seconds while the toner collection motor is on(کپی ایران ) • Motor lock due to obstruction • Motor driver board defective • Motor connection loose, defective • Toner collection motor sensor disconnected, sensor defective • Rotational transmission shaft (o6 x 30) missing 599 1-bin Exit Motor Error (Japan Only) The transport lock sensor output does not change within 300 ms after the motor switches on(کپی ایران ) • Motor overload • Motor driver defective 610 BICU – ADF communication/timeout abnormal After 1 data frame is sent to the ADF, an ACK signal is not received within 100 ms, and is not received after 3 retries(کپی ایران ) • Serial line connection unstable • External noise on the line 611 BICU – ADF communication/break reception abnormal During communication a break (Low) signal was received from the ADF(کپی ایران ) • Serial line connection unstable • Harness disconnected or defective 612 BICU – ADF communication/command abnormal A command that cannot be executed was sent from the main machine to the ADF(کپی ایران ) • A software error, result of an abnormal procedure(کپی ایران ) 620 BICU – ADF communication/timeout error After 1 data frame is sent to the finisher MBX, an ACK signal is not received within 100 ms, and is not received after 3 retries(کپی ایران ) • Serial line connection unstable • External noise on the line 621 BICU – Finisher communication/break error During communication with the finisher MBX, the BICU received a break (Low) signal from the finisher(کپی ایران ) • Serial line connection unstable • External noise on the line 623 BICU – Tray 1~4 communication/timeout error After 1 data frame is sent to the trays, an ACK signal is not received within 100 ms, and is not received after 3 retries(کپی ایران ) • Serial line connection unstable • External noise on the line 624 BICU – Tray 1~4 communication/break reception error During communication with the finisher trays, the BICU received a break (Low) signal(کپی ایران ) • Serial line connection unstable • External noise on the line 626 BICU – LCT communication/timeout error After 1 data frame is sent to the LCT, an ACK signal is not received within 100 ms, and is not received after 3 retries(کپی ایران ) • Serial line connection unstable • External noise on the line 627 BICU – LCT communication/break reception error During communication with the LCT, the BICU received a break (Low) signal(کپی ایران ) • Serial line connection unstable • External noise on the line 650 NRS Modem Communication Error One of the following factors could be the cause of this error: • In the User Tools, check the settings for the dial-up user name and dial up password(کپی ایران ) • Modem has been disconnected(کپی ایران ) • Modem board disconnected Check the following for a machine that is using Cumin (NRS modem): • An error was returned during the dialup connection • A network was detected at startup • At startup the machine detected that the NIB was disabled, or did not detect a modem board 651 Illegal Remote Service Dial-up An expected error occurred when Cumin-M dialed up the NRS Center • Software bug • No action is required because only the count is logged 670 Engine startup error The machine engine, controlled by the BICU (Base Image Control Unit), was operating incorrectly when the machine was switched on or returned to normal operation from the energy save mode(کپی ایران ) • Check the connections between BICU and controller • BICU defective • Controller board defective • PSU defective 672 Controller startup error • After power on, the line between the controller and the operation panel did not open for normal operation(کپی ایران ) • After normal startup, communication with the controller stopped(کپی ایران ) • Controller stalled • Controller installed incorrectly • Controller board defective • Operation panel harness disconnected or defective 700 ADF original pick-up error 1 Pick-up roller HP sensor signal does not change after the pick-up motor has turned on(کپی ایران ) • Pick-up roller HP sensor defective • Pick-up motor defective • Timing belt slipping, out of position • ADF main board defective 701 ADF bottom plate motor error • Bottom plate position sensor does not detect the plate after the bottom plate lift motor switches on to lift the plate(کپی ایران ) • Bottom plate HP sensor does not detect the plate after the bottom plate motor reverses to lower the plate(کپی ایران ) • Bottom plate position sensor defective • Bottom plate HP sensor defective • Bottom plate motor defective • ADF main board defective 720 Finisher transport motor error The encoder pulse of the finisher transport motor does not change state (high/low) within 600 ms and does not change after 2 retries(کپی ایران ) • Finisher transport motor defective • Transport motor harness disconnected, or defective • Finisher main board defective 721 Finisher jogger motor error • The finisher jogger HP sensor remains de-activated for more 1,000 pulses when returning to home position(کپی ایران ) • The finisher jogger HP sensor remains activated for more than 1,000 pulses when moving away from home position • Jogger HP sensor defective • Jogger mechanism overload • Jogger motor defective (not rotating) • Finisher main board defective • Harness disconnected or defective 723 Feed-Out Belt Motor (B478) The pawl of the feed-out belt did not return to the home position during the prescribed time after 2 attempts to detect • Stack feed-out belt HP sensor loose, broken, defective • Feed-out belt motor defective • Finisher control board defective 724 Finisher staple hammer motor error (B478) The staple hammer motor did not return to the home position within the prescribed time (340 ms)(کپی ایران ) • Staple hammer HP sensor loose, broken, defective • Electrical overload on the stapler drive PCB elect • Staple hammer motor defective • Finisher main board defective 725 Finisher stack feed-out motor error B140 The stack feed-out belt HP sensor does not activate within the prescribed number of pulses after the stack feed-out motor turns on and does not activate after 2 retries(کپی ایران ) • Stack feed-out HP sensor defective • Harness disconnected or defective • Stack feed-out motor defective • Finisher main board defective • Motor overload 725 Exit guide motor B246 The status of the exit guide sensor did not change at the prescribed time during operation of the exit guide(کپی ایران ) • Exit guide open sensor loose, broken, defective(کپی ایران ) • Exit guide motor defective • Finisher main board defective 726 Finisher upper tray lift motor error B140 The paper height sensor does not activate within the prescribed time after the upper tray lift motor turns on, or the sensor remains on after the motor reverses to lower the tray(کپی ایران ) • Upper tray paper height sensor defective • Sensor harness disconnected, defective • Tray lift motor defective • Finisher main board defective • Tray lift motor overload 726 Front shift jogger motor error (B703) B246 The sides fences do not retract within the prescribed time after the shift jogger motor switches on(کپی ایران ) The 1st detection failure issues a jam error, and the 2nd failure issues this SC code(کپی ایران ) • Shift jogger motor disconnected, defective • Shift jogger motor overloaded due to obstruction • Shift jogger HP sensor disconnected, defective 727 Finisher stapler rotation motor error B140 The stapler motor switches on but the motor does not return to the home position within the prescribed number of pulses(کپی ایران ) After 2 counts, the SC is logged as a jam(کپی ایران ) • Stapler rotation motor defective • Poor stapler rotation motor connection • Stapler rotation sensor defective • Finisher main board defective • Rotation motor overload 727 Rear shift jogger motor (B703) B246 The side fences do not retract within the prescribed time after the shift jogger motor switches on(کپی ایران ) The 1st detection failure issues a jam error, and the 2nd failure issues this SC code(کپی ایران ) • Motor harness disconnected, loose, defective • Motor defective • Motor overload • HP defective 728 Shift jogger retraction motor error (B703) B246 The side fences do not retract within the prescribed time after the retraction motor switches on(کپی ایران ) The 1st detection failure issues a jam error, and the 2nd failure issues this SC code(کپی ایران ) • Motor harness disconnected, loose, defective • Motor defective • Motor overload • HP defective 729 Finisher punch motor error The punch HP sensor does not activate within the prescribed time after the punch motor turns on(کپی ایران ) • Punch HP sensor defective • Sensor harness disconnected, defective • Punch motor defective • Finisher main board defective • Poor punch motor overload 730 Finisher stapler movement motor error B140 The stapler HP sensor does activate within the prescribed time after the stapler motor turns on and moves the stapler away from home position(کپی ایران ) After 2 counts, the SC is logged as a jam(کپی ایران ) • Stapler HP sensor defective • Sensor harness disconnected, defective • Stapler movement motor defective • Finisher main board defective • Stapler movement motor overload 730 Finisher Tray 1 shift motor error B246 The shift roller HP sensor of the upper tray does not activate within the prescribed time after the shift tray starts to move toward or away from the home position(کپی ایران ) The 1st detection failure issues a jam error, and the 2nd failure issues this SC code • Shift tray HP sensor of the upper tray disconnected, defective • Shift tray motor of the upper tray is disconnected, defective • Shift tray motor of the upper tray overloaded due to obstruction 732 Finisher shift roller motor error The shift roller HP sensor does not activate within the prescribed time after the shift roller motor turns on(کپی ایران ) After 2 counts, the SC is logged as a jam(کپی ایران ) • Shift roller HP sensor defective • Sensor harness disconnected, defective • Shift roller motor defective • Finisher main board defective • Shift roller motor overload 733 Finisher lower tray lift motor error After the lift motor switches on to lift the tray, paper height sensor 2 does not detect the top of the paper stack, or after the motor reverses to lower the stack the top of the stack remains detected (the status of paper height sensor 1 does not change)(کپی ایران ) After 2 counts, the SC is logged as a jam(کپی ایران ) • Paper height sensor 1 or 2 defective • Sensor harness disconnected, defective • Tray lift motor defective • Finisher main board defective • Tray lift motor overload 735 Finisher pre-stack motor error • The pre-stack motor starts but does not return to the home position within 400 pulses(کپی ایران ) After 2 counts, the SC is logged as a jam(کپی ایران ) • Motor does not return to the home position within 280 pulses immediately before or after prestacking(کپی ایران ) After 2 counts, the SC is logged as a jam(کپی ایران ) • Jogger HP sensor defective • Sensor harnesses disconnected, defective • Pre-stack motor defective • Finisher main board defective • Pre-stack motor overload 736 Finisher paper exit guide plate motor error The paper exit guide plate motor starts but the paper exit guide plate HP sensor does not activate within 750 ms(کپی ایران ) After 2 counts, the SC is logged as a jam • Guide plate HP sensor defective • Sensor harness disconnected, defective • Paper exit guide plate motor defective • Finisher main board defective • Guide plate motor overload 737 Trimmed staple waste hopper full The hopper that holds the waste from staple trimming is full(کپی ایران ) • Staple waste hopper full • Staple waste sensor defective 738 Finisher pressure plate motor error The pressure plate motor switches on but does not return to the home position within the prescribed time after 2 counts • HP sensor defective • Harness disconnected, defective • Motor defective • Finisher main board defective • Motor overload 739 Finisher folder plate motor error The folder plate motor turns on but the plate does not return to the home position within the prescribed time for 2 counts • Plate HP sensor defective • Harness disconnected, defective • Folder plate motor defective • Finisher main board defective • Folder plate motor overload 740 Finisher front saddle-stitch stapler motor error B140 Saddle-stitch stapler motor fails to operate within 450 ms within 2 counts(کپی ایران )(کپی ایران ) • HP sensor defective • Harness disconnected, defective • Stapler motor defective • Finisher main board defective • Stapler motor overload 740 Finisher corner stapler motor error B246 The stapler motor does not switch off within the prescribed time after operating(کپی ایران ) The 1st detection failure issues a jam error, and the 2nd failure issues this SC code(کپی ایران ) • Staple jam • Number of sheets in the stack exceeds the limit for stapling • Stapler motor disconnected, defective 741 Finisher rear saddle-stitch stapler motor error B140 Saddle-stitch stapler motor fails to operate within 450 ms within 2 counts(کپی ایران )(کپی ایران ) • HP sensor defective • Harness disconnected, defective • Stapler motor defective • Finisher main board defective • Stapler motor overload 741 Finisher corner stapler rotation motor error B246 The stapler does not return to its home position within the specified time after stapling(کپی ایران ) The 1st detection failure issues a jam error, and the 2nd failure issues this SC code(کپی ایران ) • Stapler rotation motor disconnected, defective • Stapler rotation motor overloaded due to obstruction • Stapler rotation HP sensor disconnected, defective 742 Finisher jogger side fence motor error B140 The jogger motor turns on but the side fences to not return to the home position within 340 pulses for 2 counts(کپی ایران ) • HP sensors defective • Harness disconnected, defective • Motor defective • Finisher main board defective • Motor overload 762 Finisher pressure plate motor error Pressure plate motor operating but the plate is not detected at the home position within the specified time(کپی ایران ) The 1st detection failure issues a jam error, and the 2nd failure issues this SC code(کپی ایران ) • Pressure plate HP sensor disconnected, defective • Pressure plate motor disconnected, defective • Pressure plate motor overloaded due to obstruction 763 Punch movement motor error Occurs during operation of the punch unit(کپی ایران ) The 1st detection failure issues a jam error, and the 2nd failure issues this SC code • Motor harness disconnected, loose, defective • Motor defective 764 Paper position sensor slide motor error Occurs during operation of the punch unit(کپی ایران ) The 1st detection failure issues a jam error, and the 2nd failure issues this SC code(کپی ایران ) • Motor harness disconnected, loose, defective • Motor defective 765 Folding unit bottom fence lift motor The 1st detection failure issues a jam error, and the 2nd failure issues this SC code • Motor harness disconnected, loose, defective • Motor defective 766 Clamp roller retraction motor error The 1st detection failure issues a jam error, and the 2nd failure issues this SC code • Motor harness disconnected, loose, defective • Motor defective 767 Stack junction gate motor error Occurs during operation of the punch unit(کپی ایران ) The 1st detection failure issues a jam error, and the 2nd failure issues this SC code(کپی ایران ) • Motor harness disconnected, loose, defective • Motor overload • Motor defective 770 Cover interposer tray bottom plate motor error • After the motor starts to raise the bottom plate, the bottom plate position sensor does not detect the plate at the specified time (3 s)(کپی ایران ) • After the motor starts to lower the bottom plate, the bottom plate HP sensor does not detect the bottom plate • Bottom plate position sensor, disconnected, defective • Bottom plate HP sensor disconnected, defective 780 Z-Fold feed motor error The feed motor does not attain the prescribed speed within the specified time(کپی ایران ) • Feed motor disconnected, defective • Feed motor overloaded due to obstruction • Feed motor lock 781 Z-Fold lower stopper motor The lower stopper motor does not attain the prescribed speed within the specified time(کپی ایران ) • Lower stopper motor disconnected, defective • Lower stopper motor overloaded due to obstruction • Lower stopper HP sensor disconnected, defec 782 Z-Fold upper stopper motor The upper stopper was not detected at the home position after the motor remained on long enough to move it 128(کپی ایران )7 mm(کپی ایران ) • Upper stopper motor disconnected, defective • Upper stopper motor overloaded due to obstruction • Upper stopper HP sensor disconnected, defective 784 Z-fold timing unit fold timing sensor adjustment error The A/D (Digital/Analog) input value did not change even after the D/A (Digital/Analog) output value changed(کپی ایران ) • Fold timing sensor connector loose, broken, defective • Fold timing sensor defective • Fold timing sensor, mylar covered with paper dust • Mylar disconnected 785 Z-fold leading edge sensor adjustment error The A/D input value did not change even after the D/A output value changed • Leading edge sensor connector loose, broken, defective • Leading edge sensor defective • Leading edge sensor, mylar covered with paper dust • Mylar disconnected 786 Z-fold EEPROM error The write operation to the Z-folding EEPROM failed after 2 attempts • EEPROM defective 790 Finisher staple trimming hopper full The staple waste hopper is full of cut staples • If the hopper is full, empty the hopper • If the hopper is not full, the hopper full sensor is disconnected, defective 817 Monitor Error This is a file detection and electronic file signature check error when the boot loader attempts to read the selfdiagnostic module, system kernel, or root system files from the OS Flash ROM, or the items on the SD card in the controller slot are false or corrupted(کپی ایران ) • OS Flash ROM data defective; change the controller firmware • SD card data defective; use another SD card 818 Watchdog error While the system program is running, a bus hold or interrupt program goes into an endless loop, preventing any other programs from executing(کپی ایران ) • System program defective; switch off/on, or change the controller firmware if the problem cannot be solved • Controller board defective • Controller option malfunction 819 Fatal kernel error Due to a control error, a RAM overflow occurred during system processing(کپی ایران ) One of the following messages was displayed on the operation panel(کپی ایران ) • System program defective • Controller board defective • Optional board defective • Replace controller firmware 821 Self-diagnostic error 2: ASIC The ASIC provides the central point for the control of bus arbitration for CPU access, for option bus and SDRAM access, for SDRAM refresh, and for management of the internal bus gate(کپی ایران ) 822 Self-diagnostic error 3: HDD 824 Self-diagnostic error 4: NVRAM NVRAM device does not exist, NVRAM device is damaged, NVRAM socket damaged • NVRAM defective • Controller board defective • NVRAM backup battery exhausted • NVRAM socket damaged 826 Self-diagnostic error 6: NVRAM (option NVRAM) 828 Self-diagnostic error 7: ROM • Measuring the CRC for the boot monitor and operating system program results in an error(کپی ایران ) • A check of the CRC value for ROMFS of the entire ROM area results in an error • Software defective • Controller board defective • ROM defective 833 Self-diagnostic error 8: Engine I/F ASIC 834 Self-diagnostic error 9: Optional Memory RAM DIMM 850 Net I/F error • Duplicate IP addresses(کپی ایران ) • Illegal IP address(کپی ایران ) • Driver unstable and cannot be used on the network(کپی ایران ) • IP address setting incorrect • NIB (PHY) board defective • Controller board defective 851 IEEE 1394 I/F error Driver setting incorrect and cannot be used by the 1394 I/F(کپی ایران ) • NIB (PHY), LINK module defective; change the Interface Board • Controller board defective 853 Wireless LAN Error 1 During machine start-up, the machine can get access to the board that holds the wireless LAN, but not to the wireless LAN card (802(کپی ایران )11b or Bluetooth)(کپی ایران ) • Wireless LAN card missing (was removed) 854 Wireless LAN Error 2 During machine operation, the machine can get access to the board that holds the wireless LAN, but not to the wireless LAN card (802(کپی ایران )11b or Bluetooth)(کپی ایران ) • Wireless LAN card missing (was removed) 855 Wireless LAN error 3 An error was detected on the wireless LAN card (802(کپی ایران )11b or Bluetooth)(کپی ایران ) • Wireless LAN card defective • Wireless LAN card connection incorrect 856 Wireless LAN error 4 An error was detected on the wireless LAN card (802(کپی ایران )11b or Bluetooth)(کپی ایران ) • Wireless LAN card defective • PCI connector (to the mother board) loose 857 USB I/F Error The USB driver is not stable and caused an error(کپی ایران ) • Bad USB card connection • Replace the controller board 860 HDD startup error at main power on • HDD is connected but a driver error is detected(کپی ایران ) • The driver does not respond with the status of the HDD within 30 s(کپی ایران ) • HDD is not initialized • Level data is corrupted • HDD is defective 861 HDD re-try failure At power on with the HDD detected, power supply to the HDD is interrupted, after the HDD is awakened from the sleep mode, the HDD is not ready within 30 s(کپی ایران ) • Harness between HDD and board disconnected, defective • HDD power connector disconnected • HDD defective • Controller board defective 863 HDD data read failure The data written to the HDD cannot be read normally, due to bad sectors generated during operation • HDD defective Note: If the bad sectors are generated at the image partition, the bad sector information is written to NVRAM, and the next time the HDD is accessed, these bad sectors will not be accessed for read/write operation(کپی ایران ) 864 HDD data CRC error During HDD operation, the HDD cannot respond to an CRC error query(کپی ایران ) Data transfer did not execute normally while data was being written to the HDD(کپی ایران ) • HDD defective 865 HDD access error HDD responded to an error during operation for a condition other than those for SC863, 864(کپی ایران ) • HDD defective 866 SC card error 1: Confirmation The machine detects an electronic license error in the application on the SD card in the controller slot immediately after the machine is turned on(کپی ایران ) The program on the SD card contains electronic confirmation license data(کپی ایران ) If the program does not contain this license data, or if the result of the check shows that the license data in the program on the SD card is incorrect, then the checked program cannot execute and this SC code is displayed(کپی ایران ) • Program missing from the SD card • Download the correct program for the machine to the SD card 867 SD card error 2: SD card removed The SD card in the boot slot when the machine was turned on was removed while the machine was on(کپی ایران ) • Insert the SD card, then turn the machine off and on(کپی ایران ) 868 SD card error 3: SC card access An error occurred while an SD card was used(کپی ایران ) • SD card not inserted correctly • SD card defective • Controller board defective Note: If you want to try to reformat the SC card, use SD Formatter Ver 1(کپی ایران )1 870 Address book data error Address book data on the hard disk was detected as abnormal when it was accessed from either the operation panel or the network(کپی ایران ) The address book data cannot be read from the HDD or SD card where it is stored, or the data read from the media is defective(کپی ایران ) • Software defective(کپی ایران ) Turn the machine off/on(کپی ایران ) If this is not the solution for the problem, then replace the controller firmware(کپی ایران ) • HDD defective(کپی ایران ) 873 HDD mail send data error An error was detected on the HDD immediately after the machine was turned on, or power was turned off while the machine used the HDD(کپی ایران ) • Do SP5832-007 (Format HDD – Mail TX Data) to initialize the HDD(کپی ایران ) • Replace the HDD 874 Delete All error 1: HDD A data error was detected for the HDD/NVRAM after the Delete All option was used(کپی ایران ) Note: The source of this error is the Data Overwrite Security Unit B660 running from an SD card(کپی ایران ) • Turn the main switch off/on and try the operation again(کپی ایران ) • Install the Data Overwrite Security Unit again(کپی ایران ) For more, see section “1(کپی ایران ) Installation”(کپی ایران ) • HDD defective 875 Delete All error 2: Data area An error occurred while the machine deleted data from the HDD(کپی ایران ) Note: The source of this error is the Data Overwrite Security Unit B660 running from an SD card(کپی ایران ) • Turn the main switch off/on and try the operation again(کپی ایران ) 880 File Format Converter (MLB) error A request to get access to the MLB was not answered within the specified time(کپی ایران ) • MLB defective, replace the MLB 900 Electrical total counter error The total counter contains something that is not a number(کپی ایران ) • NVRAM incorrect type • NVRAM defective • NVRAM data scrambled • Unexpected error from external source 901 Mechanical total counter error The mechanical counter is not connected(کپی ایران ) • Mechanical total counter defective • Mechanical total counter connector not connected 910 (کپی ایران )(کپی ایران )(کپی ایران ) 914 External Controller Error The external controller alerted the machine about an error(کپی ایران ) • Please refer to the instructions for the external controller(کپی ایران ) 919 External Controller Error 6 While EAC (External Application Converter), the conversion module, was operating normally, the receipt of a power line interrupt signal from the FLUTE serial driver was detected, or BREAK signal from the other station was detected(کپی ایران ) • Power outage at the EFI controller • EFI controller was rebooted • Connection to EFI controller loo 920 Printer error 1 An internal application error was detected and operation cannot continue(کپی ایران ) • Software defective; turn the machine off/on, or change the controller firmware • Insufficient memory 921 Printer error 2 When the application started, the necessary font was not on the SD card(کپی ایران ) • Font not on the SC card 925 NetFile Function Error • The NetFile file management on the HDD cannot be used, or a NetFile management file is corrupted and operation cannot continue(کپی ایران ) • The HDDs are defective and they cannot be debugged or partitioned, so the Scan Router functions (delivery of received faxes, document capture, etc(کپی ایران )), Fabric services, and other network functions cannot be used(کپی ایران )( HDD status codes displayed on the debug console are described below(کپی ایران )) • HDD defective • Power supply to machine cut occurred while writing data to HDD • Software error • Please refer to the detailed descriptions below for recovery procedures(کپی ایران ) 953 Scanner image setting error The settings required for image processing using the scanner are not sent from the IPU(کپی ایران ) • Software defective 954 Printer image setting error The settings required for image processing using the printer controller are not sent from the IPU(کپی ایران ) • Software defective 955 Memory setting error The settings that are required for image processing using the memory are not sent from the IPU(کپی ایران ) • Software defective 964 Printer ready error The print ready signal is not generated for more than 17 seconds after the IPU received the print start signal(کپی ایران ) • Software defective 984 Print image data transfer error After a data transfer begins from the controller to the engine via the PCI bus, the transfer does not end within 15 s(کپی ایران ) • Controller (SIMAC) board defective • BICU defective • BICU – controller disconnected 985 Scanned image data transmission error After a data transfer begins from the engine to the controller via the PCI bus, the transfer does not end within 3 s(کپی ایران ) • Controller (SIMAC) board defective • BICU defective • BICU – controller disconnected 986 Software error 1 The write parameter received by the write module at the beginning of the setting table is NULL • Controller (SIMAC) board defective • BICU defective • BICU – controller disconnected 990 Software error 2 The software performs an unexpected function and the program cannot continue(کپی ایران ) • Software defective, re-boot 991 Software error 3 The software performs an unexpected function and the program cannot continue(کپی ایران ) However, unlike SC990, recovery processing allows the program to continue(کپی ایران ) Software defective, re-boot 992 Software error 4: Undefined An error not controlled by the system occurred (the error does not come under any other SC code)(کپی ایران ) • Software defective • Turn the machine power off and on(کپی ایران ) The machine cannot be used until this error is cleared(کپی ایران ) 994 Operation Panel Management Records Exceeded An error occurred because the number of records exceeded the limit for images managed in the service layer of the firmware(کپی ایران ) This can occur if there if there are too many application screens open on the operation panel(کپی ایران ) • No action required because this SC does not interfere with operation of the machine 997 Cannot select application function An application does not start after the user pushed the correct key on the operation panel(کپی ایران ) • Software bug • A RAM or DIMM option necessary for the application is not installed or not installed correctly(کپی ایران ) 998 Application cannot start Register processing does not operate for an application within 60 s after the machine power is turned on(کپی ایران ) No applications not start correctly, and all end abnormally(کپی ایران ) • Software bug • A RAM or DIMM option necessary for the application is not installed or not installed correctly ادامه بدهیدمقالههای مرتبط سرویس مانوئل های ریکو آفیشوNo.7745 ۱۶ اردیبهشت ۱۴۰۱ · ۱۳ دقیقه ریکوآفشیوRicoh Aficio 1015 سرویس مانوئل های ریکو آفیشوNo.7744 ۱۶ اردیبهشت ۱۴۰۱ · ۶۱ دقیقه ریکو آفشیو Ricoh Aficio 1013 سرویس مانوئل های ریکو آفیشوNo.9236 ۱۰ فروردین ۱۳۹۵ · ۱ دقیقه https://telegram.me/copyi