شارپ Sharp MX4500FN

 

لیست کدهای خطا دستگاه Sharp MX4500FN

ایرادات دستگاه‌های شارپ براساس کد خطا نمایش داده می‌شوند.
در جدول زیر کدها، توضیح انگلیسی و شرح/علت احتمالی هر خطا بر اساس متن ارسالی شما آورده شده است، تا بتوانید به‌راحتی در سایت یا مستندات خود از آن استفاده کنید.

جدول کامل کدهای خطا

کد خطا عنوان (انگلیسی) توضیح / علت احتمالی
A0-01 PCU ROM abnormality PCU ROM content trouble – Firmware upgrade is not made properly due to power OFF, etc.
A0-02 SCU ROM abnormality SCU ROM content trouble – Some part of SFU is not upgraded during upgrading of the firmware.
A0-10 Controller ROM error SFU combination error in the controller – SFU upgrade was not properly made when upgrading the firmware.
A0-11 IF version discrepancy (CTL-PCU) Combination error between CTL and PCU.
A0-12 IF version discrepancy (CTL-SCU) Combination error between CTL and SCU.
A0-20 Machine level error (CTL detection) Combination error between the machine production/remodeling and the firmware.
A0-21 Machine level error (PCU detection) Combination error between the machine production/remodeling and the firmware.
A0-22 Machine level error (SCU detection) Combination error between the machine production/remodeling and the firmware.
E6-10 Back-face shading trouble black correction (DSPF) CCD black scan level abnormality when the copy lamp is turned off (MX-3501N/4501N). Installation error of the CCD unit flat cable, CCD unit abnormality, SCU PWB abnormality.
E6-11 Shading trouble white correction (DSPF) CCD white scan level abnormality when the copy lamp is on (MX-3501N/4501N). Installation error of the CCD unit flat cable, dirt on mirror/lens/reference white plate, copy lamp lighting trouble, CCD unit abnormality, SCU PWB abnormality.
E6-14 Back-face SCAN-ASIC trouble Written register value cannot be read correctly – SCU PWB abnormality.
E7-00 System memory access error System memory trouble (Tandem memory cannot be guaranteed). Access to system memory cannot be made. Expansion memory instillation error, garbled data, dirt on the memory pin.
E7-01 System data trouble ICU data trouble occurs – ICU image transfer trouble.
E7-03 HDD trouble HDD connection trouble, file control area data trouble (when FAT is broken). The HDD is not properly installed to the MFPcnt PWB, the HDD does not work properly, MFPcnt PWB trouble.
E7-05 Local memory access error Local memory cannot be accessed. Local memory installation abnormality, dirt on local memory pin, garbled data.
E7-06 Decode error trouble (Compression decode error) A compression file cannot be decompressed. A decode error occurs when forming an image. Compression data abnormality, HDD connection abnormality, data garbled in image compression/send, MFPcnt PWB abnormality, local memory access trouble.
E7-08 Local memory specifications error DIMM of different specification is detected in the local memory slot – DIMM of different specification is installed to the local memory slot.
E7-09 Local memory combination error Local memory slot combination error – DIMM of other than 256MB is installed to the default or expansion slot.
E7-10 Shading trouble (Black correction) CCD black scan level abnormality when the copy lamp is turned off. Installation error of the CCD unit flat cable, CCD unit abnormality, SCU PWB abnormality.
E7-11 Shading trouble (White correction) CCD white scan level abnormality when the copy lamp is on. Installation error of the CCD unit flat cable, dirt on mirror/lens/reference white plate, copy lamp lighting trouble, CCD unit abnormality, SCU PWB abnormality.
E7-14 SCAN-ASIC trouble Written register value cannot be read correctly – SCU PWB abnormality.
E7-20 LSU BD detection trouble LSU BD signal is not detected. Disconnection/improper connection of harness and connector between LD/BD PWB and LSUcnt PWB. Possible causes: optical axis shift, BK laser deterioration/power reduction, BD PWB trouble.
E7-21 LSU LD deterioration trouble The color laser does not light up normally. Disconnection/improper connection of harness and connector between LD PWB and LSUcnt PWB, Y/M/C laser deterioration.
E7-28 LSU control ASIC connection abnormality Access error between the CPU of the PCU PWB and the LSU control ASIC. When occurring at initial power-on: communication connector trouble between PCU PWB and LSUcnt PWB (interface PWB), harness trouble. During print/SIM61-1: connector/harness trouble between PCU and LSUcnt PWB, PCU PWB or LSUcnt PWB trouble.
E7-29 LSU-ASIC frequency abnormality Oscillation trouble of the external oscillator used in LSU-ASIC and the internal oscillation circuit. Trouble of the oscillator on the LSU-ASIC PWB, resistor/capacitor for oscillation circuit, or LSU-ASIC itself.
E7-50 Engine connection trouble Unknown PWB identification information is detected in the PCU PWB. A PWB which is incompatible with machine specifications is connected, or incompatible firmware is used.
E7-55 PWB information sum error (Engine detection) EEPROM PWB information sum error. Causes: EEPROM device error, EEPROM device contact failure, device access error due to noises.
E7-60 Controller connection trouble (Engine detection) Unknown PWB kind information is detected in the MFPcnt PWB. A PWB/firmware which is not compatible with the machine specifications is connected. Controller PWB trouble, incompatible firmware applied.
E7-61 Controller connection trouble (Engine) MFPcnt PWB connection trouble. Compatibility trouble between controller and engine – combination trouble of controller PWB and engine.
E7-62 Controller connection trouble (Scanner) Controller connection trouble/compatibility trouble between controller and scanner – combination trouble between controller PWB and engine.
E7-65 PWB information sum error (Controller detection) EEPROM PWB information sum error – EEPROM device trouble, contact failure, or device access error due to noises.
E7-70 Scanner connection trouble Unknown identification information is detected in the SCU PWB. SCU PWB trouble, or firmware incompatible with machine specifications is connected.
E7-75 PWB information sum error (Scanner detection) EEPROM PWB information sum error – EEPROM device trouble, contact failure, or access error due to noises.
E7-80 Communication trouble between the controller and the scanner Communication trouble between the MFP and the scanner (MFP detection). Communication establishment error / framing / parity / protocol error. SCU PWB connector connection trouble, harness trouble between SCU PWB and MFPcnt PWB, broken connector pin of SCU PWB motherboard.
E7-90 Communication trouble between the controller and the engine Communication trouble between the MFP and PCU (MFP detection). Communication establishment error / framing / parity / protocol error. PCU PWB connector connection trouble, harness trouble between PCU PWB and MFPcnt PWB, broken connector pin of PCU PWB motherboard.
EE-EC Auto developer adjustment trouble The sample level for every rotation is other than 128 (SIM25-2 only, no trouble memory). Toner density sensor trouble, charging/developing voltage trouble, toner density trouble, developing unit trouble, PCU PWB trouble.
EE-EL Auto developer adjustment trouble (overtoner error) The sample level is 76 or below, or control voltage is 208V or above (SIM25-2 only). Toner density sensor trouble, charging/developing voltage trouble, toner density trouble, developing unit trouble, PCU PWB trouble.
EE-EU Auto development adjustment trouble (Under-toner abnormality) The sample level is 178 or above, or control voltage is 51V or below (SIM25-2 only). Toner density sensor trouble, charging/developing voltage trouble, toner density trouble, developing unit trouble, PCU PWB trouble.
F1-00 Finisher communication trouble (Machine side detection) Communication line test error when turning on the power or after cancelling exclusion simulation. Communication error with finisher – malfunction due to noises, PCU–finisher connector or harness connection error/disconnection, finisher control PWB trouble, PCU control PWB trouble.
F1-02 Saddle finisher transport motor trouble Transport drive motor trouble – motor lock, motor RPM abnormality, motor overvoltage, saddle finisher control PWB trouble.
F1-03 Finisher paddle / swing motor trouble Paddle motor operation trouble (MX-FNX2) / swing motor operation trouble (MX-FNX1). Motor lock, motor RPM abnormality, motor overvoltage, finisher control PWB trouble.
F1-08 Finisher stapler shift motor trouble Stapler shift motor operation trouble – motor lock, motor RPM abnormality, motor overvoltage, finisher control PWB trouble.
F1-10 Finisher staple motor abnormality Staple operation trouble – motor lock, motor RPM abnormality, motor overvoltage, saddle finisher control PWB trouble.
F1-11 Finisher bundle process motor abnormality Bundle process motor trouble – motor lock, motor RPM abnormality, motor overvoltage, finisher control PWB trouble (MX-FNX2).
F1-15 Finisher tray lift motor abnormality Lift motor trouble – motor lock, motor RPM abnormality, motor overvoltage, finisher control PWB trouble.
F1-19 Finisher pre-alignment motor abnormality Pre-alignment motor trouble – motor lock, motor RPM abnormality, motor overvoltage, saddle finisher control PWB trouble.
F1-20 Finisher after-alignment motor abnormality After-alignment motor trouble – motor lock, motor RPM abnormality, motor overvoltage, finisher control PWB trouble.
F1-21 Finisher fan motor / interface fan motor abnormality Cooling fan motor trouble (MX-FNX1) / interface transport fan motor trouble (MX-FNX2). Motor lock, motor RPM abnormality, motor overvoltage, finisher control PWB trouble.
F1-31 Finisher folding sensor trouble (MX-FNX2) Sensor input value abnormality – sensor breakage, harness disconnection, finisher control PWB trouble (MX-FNX2).
F1-32 Communication trouble between finisher and punch unit (MX-FNX2) Finisher and punch unit communication trouble. Malfunction due to noises, connector/harness connection error or disconnection, finisher control PWB trouble (MX-FNX2), PCU control PWB trouble.
F1-33 Finisher punch shift motor trouble Punch shift motor operation abnormality – motor lock, motor RPM abnormality, motor overvoltage, finisher control PWB trouble, punch control PWB trouble (MX-FNX2).
F1-34 Finisher punch motor trouble Punch motor operation abnormality – motor lock, motor RPM abnormality, motor overvoltage, finisher control PWB trouble, punch control PWB trouble (MX-FNX2).
F1-35 Finisher punch side registration sensor trouble (MX-FNX2) Sensor input value abnormality – sensor breakage, harness disconnection, saddle finisher control PWB trouble (MX-FNX2), punch control PWB trouble (MX-FNX2).
F1-36 Finisher punch registration sensor trouble (MX-FNX2) Sensor input value abnormality – sensor breakage, harness disconnection, saddle finisher control PWB trouble (MX-FNX2), punch control PWB trouble (MX-FNX2).
F1-37 Finisher backup RAM trouble Backup RAM data garbled – finisher control PWB trouble, malfunction due to electrical noises.
F1-38 Finisher punch backup RAM trouble (MX-FNX2) Punch unit backup RAM data garbled – punch control PWB trouble, malfunction due to electrical noises.
F1-39 Finisher punch dust sensor trouble (MX-FNX2) Punch dust sensor detection trouble – sensor breakage, harness disconnection, finisher control PWB trouble (MX-FNX2), punch control PWB trouble (MX-FNX2).
F1-40 Saddle finisher punch power interruption trouble (MX-FNX2) When the punch unit power interruption is detected – harness disconnection, punch control PWB trouble.
F1-50 Finisher incompatibility trouble Detection of finisher incompatible with MX-3500**/4500**/3501**/4501**. Connection of AR-F13, etc., incompatible with these models is detected.