کانون Canon iR2025
- The main thermistor reading does not reach 40C 14 sec after the fixing heater goes ON (fixing low temperature error) 1) Wiring Is the connection of the connector (CN8) on the power supply PCB and the connector (J103) on the DC controller PCB and the wiring to the fixing assembly normal? NO : Correct the connection and wiring copyir copyir.comcom 2) Fixing assembly Try replacing the fixing assembly copyir copyir.comcom Is the fault corrected? YES : End copyir copyir.comcom 3) Power supply PCB, DC controller PCB Try repacking the power supply PCB copyir copyir.comcom Is the fault corrected? YES : End copyir copyir.comcom NO : Replace the DC controller PCB copyir copyir.comcom 4) Error With the power switch ON, clear E000 through E004; then, turn off and then on the power switch copyir copyir.comcom
E001 The main thermistor reading reaches 220°C or higher (fixing high temperature error) 1) Wiring Is the connection of the connector (CN8) on the power supply PCB and the connector (J103) on the DC controller PCB and the wiring to the fixing assembly normal? NO : Correct the connection and wiring copyir copyir.comcom 2) Fixing assembly Try replacing the fixing assembly copyir copyir.comcom Is the fault corrected? YES : End copyir copyir.comcom 3) Power supply PCB, DC controller PCB Try repacking the power supply PCB copyir copyir.comcom Is the fault corrected? YES : End copyir copyir.comcom NO : Replace the DC controller PCB copyir copyir.comcom 4) Error With the power switch ON, clear E000 through E004; then, turn off and then on the power switch copyir copyir.comcom
E002 A start-up fault is detected under any of the following conditions of the main thermistor (start-up detection fault):
after exceeding 40°C, it fails to reach 60°C within 10 sec copyir copyir.comcom
after exceeding 60°C, it fails to reach 80°C within 10 sec copyir copyir.comcom
after exceeding 180°C, it fails to reach 195°C within 10 sec copyir copyir.comcom 1) Wiring Is the connection of the connector (CN8) on the power supply PCB and the connector (J103) on the DC controller PCB and the wiring to the fixing assembly normal? NO : Correct the connection and wiring copyir copyir.comcom 2) Fixing assembly Try replacing the fixing assembly copyir copyir.comcom Is the fault corrected? YES : End copyir copyir.comcom 3) Power supply PCB, DC controller PCB Try repacking the power supply PCB copyir copyir.comcom Is the fault corrected? YES : End copyir copyir.comcom NO : Replace the DC controller PCB copyir copyir.comcom 4) Error With the power switch ON, clear E000 through E004; then, turn off and then on the power switch copyir copyir.comcom
E003 After the end of the WAIT period, the main thermistor reading is 100°C or lower copyir copyir.comcom In standby, the sub thermistor reading is 50°C or lower copyir copyir.comcom (low temperature error in fixing temperature control)
E004 At time of initialization, the ZEROXI* signal of the power supply is not detected copyir copyir.comcom
During temperature control, the ZEROXI* signal does not arrive for 3 sec continuously copyir copyir.comcom
A short circuit is detected in the triac (ASIC; fixing temperature control drive circuit error) copyir copyir.comcom
The power supply PCB is faulty copyir copyir.comcom The DC controller PCB is faulty copyir copyir.comcom)
Note: If E000 through E004 is indicated, the RAM on the image processor will retain the error memory of the fixing assembly after the power switch has been turned off an then on copyir copyir.comcom Execute the following in service mode, and turn off and then on the power switch to clear the memory:
#7 PRINTER – #4 PRINTER RESET – YES=(*) Fixing assembly is faulty copyir copyir.comcom (The main thermistor has an open circuit copyir copyir.comcom The sub thermistor has an open circuit copyir copyir.comcom The fixing heater has an open circuit copyir copyir.comcom 1) Wiring Is the connection of the connector (CN8) on the power supply PCB and the connector (J103) on the DC controller PCB and the wiring to the fixing assembly normal? NO : Correct the connection and wiring copyir copyir.comcom 2) Fixing assembly Try replacing the fixing assembly copyir copyir.comcom Is the fault corrected? YES : End copyir copyir.comcom 3) Power supply PCB, DC controller PCB Try repacking the power supply PCB copyir copyir.comcom Is the fault corrected? YES : End copyir copyir.comcom NO : Replace the DC controller PCB copyir copyir.comcom 4) Error With the power switch ON, clear E000 through E004; then, turn off and then on the power switch copyir copyir.comcom
E010 A specific revolution is not detected from the main motor rotation detection signal (MLOK*), causing the signal to go ‘1’ (main motor fault) The main motor (M101) is faulty copyir copyir.comcom The controller PCB is faulty copyir copyir.comcom 1) Connector Is the connection of the connector (J903) of the main motor and the connector (J06) on the DC controller PCB normal? NO : Correct the connection copyir copyir.comcom 2) Main motor (M101), DC controller PCB Try replacing the main motor copyir copyir.comcom Is the fault corrected? YES : Replace the main motor copyir copyir.comcom NO : Check the wiring; if normal, replace the DC controller PCB copyir copyir.comcom
E100 When the scanner motor is started up, the BD input signal does not arrive within a specific period of time copyir copyir.comcom
When the scanner motor is started up, the motor rotation is too fast, and fails to reach a specific revolution within 20 sec at time of deceleration copyir copyir.comcom
While the scanner motor is rotating at a specific speed, the BD input signal cycle is not within a specific range (±2%) for an equivalent of 10 mm (print distance) copyir copyir.comcom
While the scanner motor is rotating at a specific speed, the BD input signal cycle is not as indicated (±2%) copyir copyir.comcom
During the WMUPR period after the power switch has been turned on or the front cover/left cover has been opened/closed, the drum unit is absent copyir copyir.comcom The wiring is faulty (short circuit, open circuit) copyir copyir.comcom The laser scanner unit is faulty copyir copyir.comcom The DC controller PCB is faulty copyir copyir.comcom The drum unit is not installed copyir copyir.comcom 1) Drum unit Is the drum unit installed in host machine? NO : Install the drum unit copyir copyir.comcom 2) Connection Is the connection of the connector (J908) on the BD detection PCB, connector (J907) of the laser unit, and connector (J102) on the DC controller PCB normal? NO : Correct the connection copyir copyir.comcom 3) Laser/scanner unit, DC controller PCB Try replacing the laser/scanner unit copyir copyir.comcom Is the fault corrected? YES : End copyir copyir.comcom NO : Replace the DC controller PCB copyir copyir.comcom
E500 An error has occurred in the communication between the machine and the finisher twice continuously copyir copyir.comcom The harness to the finisher is faulty (disconnected connector, open circuit) copyir copyir.comcom The finisher controller PCB or the DC controller PCB is faulty copyir copyir.comcom 1) Power switch Try turning off and then on the power switch copyir copyir.comcom Is the fault corrected? YES : End copyir copyir.comcom 2) Wiring Is the wiring from the finisher controller PCB to the DC controller PCB normal? NO : Corrected the wiring copyir copyir.comcom 3) Finisher controller PCB, DC controller PCB Try replacing the finisher controller PCB copyir copyir.comcom Is the fault corrected? YES : End copyir copyir.comcom NO : Replace the DC controller PCB copyir copyir.comcom
E514 The stack delivery belt does not reach home position when the stack handling motor (M2) is driven for a specific time (CW; if the same condition occurs during stack delivery, a jam will be identified) copyir copyir.comcom The stack handling motor (M2) is faulty copyir copyir.comcom The stack delivery home position sensor (S8) is faulty copyir copyir.comcom The connector is disconnected or has an operation circuit copyir copyir.comcom The stack handling motor relay harness is faulty copyir copyir.comcom The stack delivery belt is faulty copyir copyir.comcom The finisher controller PCB is faulty copyir copyir.comcom 1) Stack handling motor drive belt Is the tension of the drive belt appropriate? NO : Loosen the screw on the tension to correct the tension copyir copyir.comcom 2) Wiring Is the wiring between the finisher controller PCB and the harness handling motor (M2) normal? NO : Correct the wiring copyir copyir.comcom 3) Sensor flag Are the sensor flag spring and the flag normal? NO : Correct the spring or the flag copyir copyir.comcom 4) Stack delivery lever home position sensor (S8) Check the stack delivery lever home position sensor (S8) copyir copyir.comcom Is the sensor normal? NO : Replace the sensor copyir copyir.comcom 5) Stack handling motor (M2), Finisher controller PCB Try replacing the stack handling motor (M2) copyir copyir.comcom Is the fault corrected? YES : End copyir copyir.comcom NO : Replace the finisher controller PCB copyir copyir.comcom
E530 The rear aligning plate does not reach home position when the rear alignment motor (M4) has been driven for a specific time copyir copyir.comcom
The rear aligning plate does not reach home position when the rear alignment motor (M4) has been driven for a specific time copyir copyir.comcom The rear alignment motor (M4) is faulty copyir copyir.comcom The rear aligning plate home position sensor (S7) is faulty copyir copyir.comcom The sensor connector is disconnected or has an open circuit copyir copyir.comcom The rear alignment motor relay harness is faulty copyir copyir.comcom The rear aligning plate is subjected to an abnormal load copyir copyir.comcom The finisher controller PCB is faulty copyir copyir.comcom 1) Rear aligning plate home position sensor (S7) Check the rear aligning plate home position sensor (S7) copyir copyir.comcom Is the sensor normal? NO : Replace the sensor copyir copyir.comcom 2) Wiring List the wiring between the finisher controller PCB and the rear alignment motor (M4) copyir copyir.comcom NO : Correct the wiring copyir copyir.comcom 3) Rear aligning plate Is the rack riding cover the collar of the roll? YES : Correct it copyir copyir.comcom 4) Rear alignment motor (M4), Finisher controller PCB Try replacing the rear alignment motor (M4) copyir copyir.comcom Is the fault corrected? YES : End copyir copyir.comcom NO : Replace the finisher controller PCB copyir copyir.comcom
E531 The stapler does not leave the stapling home position sensor (S13) within 0 copyir copyir.comcom5 sec after the stapler motor (M6) is rotated CW copyir copyir.comcom
The stapler does to return to the home position sensor (S13) within 0 copyir copyir.comcom5 sec after the stapler motor (M6) is driven CW and, in addition, it does not return to the sensor within 0 copyir copyir.comcom5 sec after the motor is driven CCW thereafter copyir copyir.comcom The stapler motor (M6) is faulty copyir copyir.comcom The stapler home position sensor (SW1) is faulty copyir copyir.comcom The stapler harness is faulty copyir copyir.comcom The finisher controller PCB is faulty copyir copyir.comcom 1) Wiring It the wiring between the stapler unit and the finisher controller PCB normal? NO : Correct the wiring copyir copyir.comcom 2) Stapler unit, Finisher controller PCB Try replacing the stapler unit copyir copyir.comcom Is the fault corrected? YES : End copyir copyir.comcom NO : Replace the finisher controller PCB copyir copyir.comcom
E537 The front aligning plate does not reach home position when the front aligning motor (M3) is driven for a specific time copyir copyir.comcom
The front aligning plate does not leave home position when the front alignment motor (M3) is driven for a specific time copyir copyir.comcom The front alignment motor (M3) is faulty copyir copyir.comcom The front aligning plate home position sensor (S6) is faulty copyir copyir.comcom The sensor connector is disconnected or has an open circuit copyir copyir.comcom The front alignment motor relay harness if faulty copyir copyir.comcom The front aligning plate is subjected to an abnormal load copyir copyir.comcom The finisher controller PCB is faulty copyir copyir.comcom 1) Front aligning plate home position sensor (S6) Check the front aligning plate home position sensor (S6) copyir copyir.comcom Is the sensor normal? NO : Replace the sensor copyir copyir.comcom 2) wiring Is the wiring between the finisher controller PCB and the front alignment motor (M3) normal? NO : Correct the wiring copyir copyir.comcom 3) Front aligning plate Is the rack riding over the collar of the roll? YES : Correct it copyir copyir.comcom 4) Front alignment motor (M3), Finisher controller PCB Try replacing the front alignment motor (M3) copyir copyir.comcom Is the problem corrected? YES : End copyir copyir.comcom NO : Replace the finisher controller PCB copyir copyir.comcom
E551 The delivery fan rotation signal (FNALCOK) does not arrive within 1 sec when the heat discharge fan drive signal (FANON) is sent copyir copyir.comcom The heat discharge fan (FM1) is faulty copyir copyir.comcom The heat discharge fan relay harness is faulty copyir copyir.comcom The heat discharge fan is subjected to an abnormal load copyir copyir.comcom The finisher controller PCB is faulty copyir copyir.comcom 1) Wiring Is the wiring between the heat discharge fan and the finisher controller PCB normal? NO : Correct the wiring copyir copyir.comcom 2) Heat discharge fan (FM1), Finisher controller PCB Try replacing the heat discharge fan (FM1) copyir copyir.comcom Is the fault corrected? YES : End copyir copyir.comcom NO : Replace the finisher controller PCB copyir copyir.comcom
E577 The return roller does not reach home position when the delivery motor (M1) is driven for a specific time copyir copyir.comcom (If the same condition is detected while alignment takes place in the direction of feed, a jam will be identified) The delivery motor (M1) on the finisher controller PCB is faulty copyir copyir.comcom The return roller home position sensor (S3) is faulty copyir copyir.comcom The connector is discontented or has an open circuit copyir copyir.comcom The delivery motor relay harness is faulty copyir copyir.comcom The return roller is faulty copyir copyir.comcom The finisher controller PCB is faulty copyir copyir.comcom 1) Delivery motor (drive mechanism) Is the return roller rotation when the motor is rotating CCW? NO : Correcting the drive mechanism copyir copyir.comcom Is the return roller displaced? NO : Correct the return roller spring copyir copyir.comcom Is the tension of the delivery motor drive belt appropriate? NO : Loosen the screw, and correct the tension copyir copyir.comcom 2) Return roller home position sensor (S3) Check the return roller home position sensor (S3) copyir copyir.comcom Is the sensor normal? NO : Replace the sensor copyir copyir.comcom 3) Delivery motor (M1), Finisher controller PCB Try replacing the delivery motor (M1) copyir copyir.comcom Is the fault corrected? YES : End copyir copyir.comcom NO : Replace the finisher controller PCB copyir copyir.comcom
E580 The stack tray upper limit sensor (S1) goes ON while the stack tray up/down motor (M5) is in operation copyir copyir.comcom
The clock signal of the stack tray up/down clock sensor (S9) is not detected 15 times or more within 0 copyir copyir.comcom8 sec while the stack tray up/down motor (M5) is in operation copyir copyir.comcom
It does not reach the stack tray paper height sensor (S10) 2 sec after the stack tray up/down motor (M5) rotates for ascent copyir copyir.comcom
It does not leave the stack tray power height sensor (S10) 2 sec after the stack tray up/down motor (M5) starts to rotate for descent copyir copyir.comcom The stack tray up/down motor (M5) is faulty copyir copyir.comcom The stack tray paper height sensor (S10) is faulty copyir copyir.comcom The sensor connector is disconnected or has an open circuit copyir copyir.comcom The stack tray up/down clock sensor (SW9) is faulty copyir copyir.comcom The sensor connector is disconnected or has an open circuit copyir copyir.comcom The stack tray up/down motor is subjected to an abnormal load copyir copyir.comcom The finisher controller PCB is faulty copyir copyir.comcom 1) Stack tray up/down motor (encoder) Try turning the encoder of the stack tray up/down motor by hand copyir copyir.comcom Does it rotate smoothly? NO : Correct the mechanical mechanism copyir copyir.comcom 2) Wiring Is the wiring between the finisher controller PCB and the stack tray up/down motor (M5) normal? NO : Correct the wiring copyir copyir.comcom 3) Tray phase Is the left/right phase of the stack tray normal? NO : Correct the phase copyir copyir.comcom 4) Stack tray up/down lock sensor (S9) Check the stack tray up/down clock sensor (S9) copyir copyir.comcom Is the sensor normal? NO : Replace the sensor copyir copyir.comcom 5) Stack tray paper height sensor (S10) Check the stack tray paper height sensor (S10) copyir copyir.comcom Is the sensor normal? NO : Replace the sensor copyir copyir.comcom 6) Stack tray paper limited sensor (S1), Stack tray lower limit sensor (S12) Check the stack tray upper limit sensor (S1) and the stack tray lower limit sensor (S12) copyir copyir.comcom Are the sensors normal? NO : Replace the sensors copyir copyir.comcom 7) Stack tray up/down motor (M5), Finisher controller PCB Try replacing the stack tray up/down motor (M5) copyir copyir.comcom Is the fault corrected? YES : End copyir copyir.comcom NO : Replace the finisher controller PCB copyir copyir.comcom
E585 The stack retaining lever does not reach home position when the stack handling motor (M2) has been driven for a specific time (at the start of motor CCW rotation) copyir copyir.comcom (If the same condition is detected during stack delivery, a jam will be identified) The stack handling motor (M2) is faulty copyir copyir.comcom The stack delivery lever home position sensor (S8) is faulty copyir copyir.comcom The sensor connector is disconnected or has an open circuit copyir copyir.comcom The stack handling motor relay harness is faulty copyir copyir.comcom The stack retaining lever is faulty copyir copyir.comcom The finisher controller PCB is faulty copyir copyir.comcom 1) Stack holding motor drive belt copyir copyir.comcom Is the tension of the drive belt appropriate? NO : Loosen the screw, and correct the tension copyir copyir.comcom 2) Stack handling motor (drive mechanism) Is the return roller rotating while the motor is rotating CCW? NO : Correct that drive mechanism copyir copyir.comcom 3) Wiring Is the wiring between the finisher controller PCB and the stack handling motor (M2) normal? NO : Correct the wiring copyir copyir.comcom 4) Stack retaining lever home position sensor (S4) Check the stack retaining lever home position sensor (S4) copyir copyir.comcom Is the sensor normal? NO : Replace the sensor copyir copyir.comcom 5) Stack handling motor (M2), Finisher controller PCB Try replacing the stack handling motor (M2) copyir copyir.comcom Is the fault corrected? YES : End copyir copyir.comcom NO : Replace the finisher controller PCB copyir copyir.comcom
E719 The communication between the card reader and the image processor PCB is disrupted copyir copyir.comcom
Note: If E719 is indicated, the fault in communication is retained by the RAM on the image processor even when the power switch has been turned off and then on; be sure to execute #12 CLEAR – CARD in service mode before making corrections copyir copyir.comcom The wiring is faulty (short circuit, open circuit) copyir copyir.comcom The card reader is faulty copyir copyir.comcom The image processor PCB is faulty copyir copyir.comcom 1) Connector Is the connection and the wiring for the connector (J1131) of the card reader and the connector (J210) on the image processor PCB normal? NO : Correct the connection copyir copyir.comcom 2) Image processor PCB Try replacing the card reader copyir copyir.comcom Is the fault corrected? YES : End copyir copyir.comcom NO : Replace the image processor PCB copyir copyir.comcom
E805 After the heat discharge fan drive signal is generated, the fan lock detection signal does not arrive for a specific period of time copyir copyir.comcom The fan wiring is faulty (short circuit, open circuit) copyir copyir.comcom The heat discharge fan (FM101) is fautly copyir copyir.comcom The DC controller PCB is faulty copyir copyir.comcom 1) Foreign matter Is there foreign matter that prevents the rotation of the fan? YES : Remove the foreign matter copyir copyir.comcom 2) Wiring, Connector Is the connection and wiring of the connector (J951) of the heat discharge fan (FM101) and the connector (J106) on the DC controller PCB normal? NO : Correct the wiring copyir copyir.comcom 3) Heat discharge fan (FM101), DC controller PCB Try replacing the heat discharge fan (FM101) copyir copyir.comcom Is the fault corrected? YES : End copyir copyir.comcom NO : Replace the DC controller PCB copyir copyir.comcom - The error history indicates any of the following error codes 4 times: E001, E002, E003 copyir.com Clear the error copyir.com 1) Clear the error copyir.com Execute ‘#4 PRINTER RESET” under ‘#7 PRINTER’ in service mode to clear the error copyir.com; then, turn back on the power copyir.com
E001-000 The main thermistor detects 230°C/446°F or higher for 1 sec or more copyir.com – The fixing film unit is faulty (thermistor short circuit) copyir.com The power supply PCB is faulty copyir.com The DC controller PCB is faulty copyir.com 1 copyir.com Malfunction Turn off the power; wait for 10 min, and turn it on copyir.com Is the problem corrected? YES: End copyir.com 2 copyir.com Fixing film unit Check the connector (4-pin) of the thermistor for electrical continuity: 1-2 and 3-4 copyir.com Is it 0 Ohm? YES: Replace the fixing film unit copyir.com 3 copyir.com Power supply PCB, DC controller PCB Try replacing the power supply PCB copyir.com Is the problem corrected? NO: Replace the DC controller PCB copyir.com
E001-001 The sub thermistor detects 300°C/572°F or higher for 0 copyir.com2 sec or more copyir.com – The fixing film unit is faulty (thermistor short circuit) copyir.com The power supply PCB is faulty copyir.com The DC controller PCB is faulty copyir.com 1 copyir.com Malfunction Turn off the power; wait for 10 min, and turn it on copyir.com Is the problem corrected? YES: End copyir.com 2 copyir.com Fixing film unit Check the connector (4-pin) of the thermistor for electrical continuity: 1-2 and 3-4 copyir.com Is it 0 Ohm? YES: Replace the fixing film unit copyir.com 3 copyir.com Power supply PCB, DC controller PCB Try replacing the power supply PCB copyir.com Is the problem corrected? NO: Replace the DC controller PCB copyir.com
E002-000 During printing, the main thermistor detects 0°C/32°F or lower for 1 sec or more continuously copyir.com About 10 sec or later after power-on/start of printing, the main thermistor detects less than 120°C/248°F for 1 sec or more continuously copyir.com – The fixing film unit is faulty (main thermistor fault, sub thermistor fault, thermal fuse blow, fixing heater fault) copyir.com The power supply PCB is faulty copyir.com The DC controller PCB is faulty copyir.com 1 copyir.com Malfunction Turn off the power; wait for 10 min, and turn on the power copyir.com Is the problem corrected? YES: End copyir.com 2 copyir.com Wiring Is the wiring from the DC controller PCB to the fixing film unit normal? NO: Correct the wiring copyir.com 3 copyir.com Fixing film unit Try replacing the fixing film unit copyir.com Is the problem corrected? YES: End copyir.com 4 copyir.com Power supply PCB, DC controller PCB Try replacing the power supply PCB copyir.com Is the problem corrected? YES: End copyir.com NO: Replace the DC controller PCB copyir.com
E002-001 After power-on/start of printing, the reading of the main thermistor does not reach the target value -15°C/11°F or higher within 75 sec copyir.com About 10 sec or later after the heater is supplied with power, the sub thermistor detects less than 75°C/167°F for 2 sec or more continuously copyir.com – The fixing film unit is faulty (main thermistor fault, sub thermistor fault, thermal fuse blow, fixing heater fault) copyir.com The power supply PCB is faulty copyir.com The DC controller PCB is faulty copyir.com 1 copyir.com Malfunction Turn off the power; wait for 10 min, and turn on the power copyir.com Is the problem corrected? YES: End copyir.com 2 copyir.com Wiring Is the wiring from the DC controller PCB to the fixing film unit normal? NO: Correct the wiring copyir.com 3 copyir.com Fixing film unit Try replacing the fixing film unit copyir.com Is the problem corrected? YES: End copyir.com 4 copyir.com Power supply PCB, DC controller PCB Try replacing the power supply PCB copyir.com Is the problem corrected? YES: End copyir.com NO: Replace the DC controller PCB copyir.com
E003 During printing, the main thermistor detects less than 120°C/248°F for 1 sec or more continuously copyir.com – The fixing film unit is faulty (main thermistor fault, thermal fuse blow, fixing heater fault) copyir.com The power supply PCB is faulty copyir.com The DC controller PCB is faulty copyir.com 1 copyir.com Malfunction Turn off the power; wait for 10 min, and turn on the power copyir.com Is the problem corrected? YES: End copyir.com 2 copyir.com Wiring Is the wiring from the DC controller PCB to the fixing film unit normal? NO: Correct the wiring copyir.com 3 copyir.com Fixing film unit Try replacing the fixing film unit copyir.com Is the problem corrected? YES: End copyir.com 4 copyir.com Power supply PCB, DC controller PCB Try replacing the power supply PCB copyir.com Is the problem corrected? YES: End copyir.com NO: Replace the DC controller PCB copyir.com
E100 About 1 copyir.com5 sec after the scanner drive signal output, the BDI* signal is not detected 3 times or more for 1 copyir.com0 sec copyir.com While the laser is ON, the BD signal cycle is not as indicated for 0 copyir.com5 or more continuously copyir.com – The laser driver/BD PCB is faulty (laser activation failure, BD detection fault) copyir.com The DC controller PCB is faulty copyir.com The image processor PCB is faulty copyir.com 1 copyir.com Wiring Is the wiring from the DC controller PCB to the laser scanner unit normal? NO: Correct the wiring 2 copyir.com Laser scanner unit Try replacing the laser scanner unit copyir.com Is the problem corrected? YES: End copyir.com 3 copyir.com DC controller PCB, Image processor PCB Try replacing the DC controller PCB copyir.com Is the problem corrected? YES: End copyir.com NO: Replace the image processor PCB copyir.com
E110 The scanner fails to reach the target speed of rotation 10 sec after the laser scanner motor reaches constant speed state copyir.com – The laser scanner motor is faulty copyir.com The DC controller PCB is faulty copyir.com 1 copyir.com Laser scanner unit, DC controller PCB Try replacing the laser scanner unit copyir.com Is the problem corrected? YES: End copyir.com NO: Replace the DC controller PCB copyir.com
E805 While the fan is rotating, fan lock state is detected for 10 sec or more continuously copyir.com – The fan is faulty copyir.com The DC controller PCB is faulty copyir.com The image processor PCB is faulty copyir.com 1 copyir.com Foreign matter Is there any foreign matter that hinders the rotation of the heat discharge fan? YES: Remove the foreign matter copyir.com 2 copyir.com Wiring, Connection Are the wiring and connection (connectors) of the fan normal? NO: Correct them copyir.com 3 copyir.com Fan Try replacing the fan copyir.com Is the problem corrected? YES: End copyir.com 4 copyir.com DC controller PCB/Image processors PCB Try replacing the DC controller PCB copyir.com Is the problem corrected? YES: End copyir.com NO: Replace the image processor PCB copyir.com
E810 The case that the toner bottle is detected, but not the cartridge copyir.com – The DC controller PCB is faulty copyir.com The cartridge is faulty copyir.com 1 copyir.com High-voltage contact (between machine and the developing unit) Is the high-voltage spring used to supply high voltage to the developing unit soild? YES: Clean it copyir.com 2 copyir.com High-voltage contact (between high-voltage spring and DC controller PCB; J207) Is the connection between the high-voltage spring and the DC controller PCB(J207) normal? NO: Correct the connection copyir.com If the problem cannot be corrected, replace the faulty part copyir.com 3 copyir.com Developing unit, DC controller PCB Replace the developing unit copyir.com Is the problem corrected? YES: End copyir.com NO: Replace the DC controller PCB copyir.com