C0045    Fuser fan motor error
– The LOCK signal remains HIGH or LOW continuously for a predetermined period of time while the Cooling Fan Motor remains energized    1 Check the Motor connectors for connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 M2 operation check 4 M3 operation check 5 Replace PWB-P   copyir.com
C0210    H   copyir.com V   copyir.com abnormal
– The Drum Charge Monitor Voltage (HVC_MON) signal falls outside a predetermined range at any time after the lapse of a predetermined period of time after the Power Switch has been turned ON   copyir.com
– The Image Transfer Voltage Monitor signal (T_MON_V) and Image Transfer Current Monitor signal (T_MON_I) fall outside a corresponding predetermined range    1 Replace Fusing Unit   copyir.com 2 Replace PWB-P   copyir.com
C0500    Fuser warm up error
– The voltage of the Thermistor remains low for a predetermined period of time when a warm-up cycle is started   copyir.com
– The temperature detected by the Thermistor remains lower than a reference value for a predetermined period of time for the period of time that begins 5 sec   copyir.com after, and ends 9 sec   copyir.com after, the start of the warm-up cycle (where the temperature detected by the Thermistor is 80 °C or less)   copyir.com
– The temperature detected by the Thermistor does not increase for a 3-sec   copyir.com period or more for the period of time that begins after the lapse of a predetermined period of time after the Fusing Roller Heater Lamp has been turned ON and ends when the lamp is turned OFF   copyir.com
– The Fusing Roller Heater Lamp remains ON for a 30-sec   copyir.com period or more (except during the period through which the Main Motor remains energized)   copyir.com    1 Replace Thermistor (TH1)   copyir.com 2 Replace Fusing Unit   copyir.com 3 Replace Controller/Mechanical Control Board (PWB-P)   copyir.com 4 Replace Power Unit (PU1)   copyir.com
C0510    Fuser temperature low
– The temperature detected by the Thermistor remains lower than the set temperature continuously for a predetermined period of time while the fusing temperature control is being provided   copyir.com (The set temperatures are as follows: 140 °C during a print mode at 600 dpi; 70 °C during the standby mode   copyir.com)    1 Replace Thermistor (TH1)   copyir.com 2 Replace Fusing Unit   copyir.com 3 Replace Controller/Mechanical Control Board (PWB-P)   copyir.com 4 Replace Power Unit (PU1)   copyir.com
C0520    Fuser overheat
– The temperature detected by the Thermistor remains higher than 235 °C for a predetermined period of time while the fusing temperature control is being provided   copyir.com    1 Replace Thermistor (TH1)   copyir.com 2 Replace Fusing Unit   copyir.com 3 Replace Controller/Mechanical Control Board (PWB-P)   copyir.com 4 Replace Power Unit (PU1)   copyir.com
C0650    Scanner home sensor error
– The Scanner Home Position Sensor is not detected within the predetermined period of time after the Scanner Motor has started turning   copyir.com    1 M4 operation check   copyir.com 2 Replace PWB-P   copyir.com
C1200    ASIC memory abnormal
– An error occurred while writing to or reading the SRAM on the Control Board (PWB-C)   copyir.com    1 Turn the copier off, then on again   copyir.com 2 Check the connection of the memory on the PWB-P, and then correct it if necessary   copyir.com 3 Replace PWB-P   copyir.comr unit   copyir.com
C1300    Polygon mirror motor error
– The LOCK signal is not detected within a predetermined period of time that begins 1 sec   copyir.com after the Polygon Motor has been energized   copyir.com
– No new LOCK signal is detected for a 1-sec   copyir.com period that begins 1   copyir.com5 sec   copyir.com after the first LOCK signal was detected   copyir.com
– The LOCK signal is not detected for a continuous 0   copyir.com5-sec   copyir.com period in a state in which the Polygon Motor runs stably   copyir.com
– The LOCK signal remains ON for a continuous 5-sec   copyir.com period or more when the Polygon Motor remains deenergized   copyir.com    1 Check cables for connection and correct as necessary   copyir.com 2 Replace PH Unit   copyir.com 3 Replace PWB-P   copyir.com
C133B    Communication with option error
– Communication could not be established with the Controller Control Board within 5 seconds while printing   copyir.com
C133C    Modem error
– A malfunction occurred in the Modem   copyir.com    1 Replace NCU   copyir.com
C133D    ROM checksum error
– A malfunction occurred in the ROM    1 Replace PWB-P   copyir.com
C13F0    Laser error
– The laser output exceeds the upper limit value   copyir.com
– The laser output remains lower than the lower limit value   copyir.com    1 Check cables for connection and correct as necessary   copyir.com 2 Replace PH Unit   copyir.com 3 Replace PWB-P   copyir.com
C1468    Parameter Chip error
– An Parameter Chip not written with initial data was detected   copyir.com    1 Unplug, then plug in the power cord, and turn off the copier, then turn it on again   copyir.com 2 Check the connection of the Parameter Chip on the PWBP, and then correct it if necessary   copyir.com 3 Replace PWBP   copyir.com 4 Replace Parameter Chip   copyir.com
C14A3    IR lamp malfunction
– The luminosity level of the Exposure Lamp is not stabilized within the predetermined period of time   copyir.com    1 Check the connection of the connectors, and then correct them if necessary   copyir.com 2 Replace PWB-P   copyir.com 3 Replace the Scanner Assy   copyir.com