کونیکا مینولتا Konica-Minolta bizhub 200
C0001 LCT Communication Failure
copyir.com Due to a software malfunction, etc., the time on the watchdog timer has run out and a reset is performed.
C0202 Tray 1 Elevator Failure
copyir.com The Lift copyir.comUp Sensor is not unblocked even after the set period of time has elapsed after the paper lift up operation for the drawer has begun. 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of each motor for proper drive coupling, and correct as necessary. 3 Check the PU1 connector for proper connection and correct as necessary. 4 PC6 I/O check. 5 PC12 I/O check. 6 PC114 copyir.comPF I/O check. 7 PC123 copyir.comPF I/O check. 8 M7 operation check. 9 M8 operation check. 10 M124 copyir.comPF operation check. 11 M125 copyir.comPF operation check. 12 Change PWB copyir.comA. 13 Change PWB copyir.comC2. 14 Change PU1.
C0204 Tray 2 Elevator Failure
copyir.com The Lift copyir.comUp Sensor is not unblocked even after the set period of time has elapsed after the paper lift up operation for the drawer has begun. 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of each motor for proper drive coupling, and correct as necessary. 3 Check the PU1 connector for proper connection and correct as necessary. 4 PC6 I/O check. 5 PC12 I/O check. 6 PC114 copyir.comPF I/O check. 7 PC123 copyir.comPF I/O check. 8 M7 operation check. 9 M8 operation check. 10 M124 copyir.comPF operation check. 11 M125 copyir.comPF operation check. 12 Change PWB copyir.comA. 13 Change PWB copyir.comC2. 14 Change PU1.
C0206 Tray 3 Elevator Failure
copyir.com The Lift copyir.comUp Sensor is not unblocked even after the set period of time has elapsed after the paper lift up operation for the drawer has begun. 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of each motor for proper drive coupling, and correct as necessary. 3 Check the PU1 connector for proper connection and correct as necessary. 4 PC6 I/O check. 5 PC12 I/O check. 6 PC114 copyir.comPF I/O check. 7 PC123 copyir.comPF I/O check. 8 M7 operation check. 9 M8 operation check. 10 M124 copyir.comPF operation check. 11 M125 copyir.comPF operation check. 12 Change PWB copyir.comA. 13 Change PWB copyir.comC2. 14 Change PU1.
C0208 Tray 4 Elevator Failure
copyir.com The Lift copyir.comUp Sensor is not unblocked even after the set period of time has elapsed after the paper lift up operation for the drawer has begun. 1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of each motor for proper drive coupling, and correct as necessary. 3 Check the PU1 connector for proper connection and correct as necessary. 4 PC6 I/O check. 5 PC12 I/O check. 6 PC114 copyir.comPF I/O check. 7 PC123 copyir.comPF I/O check. 8 M7 operation check. 9 M8 operation check. 10 M124 copyir.comPF operation check. 11 M125 copyir.comPF operation check. 12 Change PWB copyir.comA. 13 Change PWB copyir.comC2. 14 Change PU1.
C0209 LCT Elevator Motor Failure
copyir.com The Elevator Motor Pulse Sensor (PC10 copyir.comLCT) cannot detect both edges of H/L even after the set period of time has elapsed while the Elevator Motor (M5 copyir.comLCT) is turning backward/forward (raise/lower).
C0211 Bypass Lifting Motion Failure
copyir.com The Bypass Lift Sensor (PC29) is not blocked or unblocked even after the set period of time has elapsed after the Bypass Pick copyir.comUp Solenoid (SL3) is energized after the manual feed paper take copyir.comup operation has begun. 1 Check the SL3 connector for proper connection and correct as necessary. 2 Check cam position.. 3 PC29 I/O check PWB copyir.comA. 4 SL3 operation check. 5 Change PWB copyir.comA.
C0212 LCT Ejection Failure
copyir.com See PC copyir.com407 sevice manual
C0213 LCT Shift Gate Malfunction
copyir.com See PC copyir.com407 sevice manual
C0214 LCT Shifting Failure
copyir.com See PC copyir.com407 sevice manual
C0215 LCT Shift Motor Malfunction
copyir.com See PC copyir.com407 sevice manual
C0701 Manual Paper Size Detection Adjustment Failure
copyir.com The control value of the Manual Paper Size Detection Unit does not fall within the specified range when an adjustment is made of manual paper size detection. 1 Check the VR1 connector for proper connection and correct as necessary. 2 Readjust the VR1. 3 Replace VR1. 4 Change PWB copyir.comA.
C1080 Exit Option Communication Failure
copyir.com The connection status of a finishing option is changed after the copier has been turned on. 1 Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 2 Check the PWB copyir.comA FN and the PWB copyir.comA for proper connection, and correct as necessary. 3 Change PWB copyir.comA FN. 4 Change PWB copyir.comA.
C1183 Elevator Motor Ascent/Descent Drive Failure
copyir.com See FS copyir.com530/ PU copyir.com501/ OT copyir.com602 service manual.
C1190 Aligning Plate 1 Drive Failure
copyir.com See FS copyir.com530/ PU copyir.com501/ OT copyir.com602 service manual.
C1191 Aligning Plate 2 Drive Failure
copyir.com See FS copyir.com530/ PU copyir.com501/ OT copyir.com602 service manual.
C11A0 Paper copyir.comLifter Drive Failure
C11A1 Exit Roller Pressure/Retraction Failure
copyir.com See FS copyir.com530/ PU copyir.com501/ OT copyir.com602 service manual.
C11A2 Saddle Exit Roller Pressure/ Retraction Failure
copyir.comSee SD copyir.com507 service manual.
C11A3 Shutter Drive Failure
copyir.com See FS copyir.com530/PU copyir.com501/OT copyir.com602 service manual.
C11A4 Saddle Exit Motor Failure
copyir.com See SD copyir.com507 service manual.
C11A5 Saddle In & Out Guide Motor Failure
copyir.com copyir.com See SD copyir.com507 service manual.
C11A6 Saddle Layable Guide Motor Drive Failure
copyir.com See SD copyir.com507 service manual.
C11B0 Staple Unit CD Drive Failure
copyir.com See FS copyir.com530/PU copyir.com501/OT copyir.com602 service manual.
C11B2 Staple Drive Failure
copyir.com See FS copyir.com530/PU copyir.com501/OT copyir.com602 service manual.
C11B5 Saddle Staple 1 Drive Failure
copyir.com See SD copyir.com507 service manual.
C11B6 Saddle Staple 2 Drive Failure
copyir.com See SD copyir.com507 service manual.
C11C0 Punch Cam Motor Unit Failure
copyir.com See FS copyir.com530/PU copyir.com501/OT copyir.com602 service manual.
C11D0 Crease Motor Drive Failure
copyir.com See SD copyir.com507 service manual.
C2211 IU Motor Failure
copyir.com The IU Motor Lock signal remains set to H for a set period of time while the IU Motor is turning.
copyir.com The IU Motor Lock signal remains set to L for a set period of time while the IU Motor remains stopped. 1 Check the M2 connector for proper connection and correct as necessary. 2 Check the M2 for proper drive coupling, and correct as necessary. 3 Check the PWB copyir.comA connector for proper connection and correct as necessary. 4 M2 operation check PWB copyir.comA PJ28A copyir.com11 (REM) M copyir.com4 5 Change PWB copyir.comA. 6 Change PU1.
C2351 Toner Suction Fan Motor Failure
copyir.com The Toner Suction Fan Motor Lock signal remains set to H for a set period of time while the Toner Suction Fan Motor is turning.
copyir.com The Toner Suction Fan Motor Lock signal remains set to L for a set period of time while the Toner Suction Fan Motor remains stopped. 1 Check the M11 connector for proper connection and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 Check the PWB copyir.comA connector for proper connection and correct as necessary. 4 M11 operation check PWB copyir.comA PJ5A copyir.com13 (REM) D copyir.com14 5 Change PWB copyir.comA. 6 Change PU1.
C2431 IU Fuse Blowing Failure
copyir.com The fuse is not blown even after the lapse of a predetermined period of time. 1 Check the UN2 connector for proper connection and correct as necessary. 2 Remove the Developing Unit from the IU, and then replace UN2. 3 Run F8. 4 Change PWB copyir.comA. 5 Change PU1N.
C2557 ATDC Sensor Failure
copyir.com The scanning value of the ATDC Sensor is less than 7 % while the IU Motor is turning.
copyir.com The scanning value of the ATDC Sensor is more than 19 % while the IU Motor is turning. 1 Check the UN2 connector for proper connection and correct as necessary. 2 Remove the Developing Unit from the IU, and then replace UN2. 3 Run F8. 4 Change PWB copyir.comA. 5 Change PU1N.
C255C ATDC Adjustment Failure
copyir.com The adjustment of the ATDC control voltage could not be completed in the set period of time when function F8 is run.
copyir.com The ATDC control voltage was not within the range of 5.39 V to 8.15 V when function F8 is run. 1 Check the UN2 connector for proper connection and correct as necessary. 2 Remove the Developing Unit from the IU, and then replace UN2. 3 Run F8. 4 Change PWB copyir.comA. 5 Change PU1N.
C2654 EEPROM Failure
copyir.com An EEPROM where no initial data is written is detected 1 Disconnect and then connect the power cord. Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 2 Check the EEPROM on the Mechanical Control Board for proper connection, and correct as necessary. 3 Change PWB copyir.comA. 4 Change EEPROM.
C2702 Abnormal Image Transfer Voltage
copyir.com The image transfer voltage exceeds 100 V for the set period of time while the IU Motor remains stopped. 1 Check the installation of the Transfer Roller. 2 Change HV1
C3451 Fusing Warm copyir.comUp Failure (Main)
copyir.com The Fusing Roller Thermistor does not detect the required temperature within 30 sec. after a warmup cycle has begun; therefore, the copier does not complete the warm copyir.comup cycle.
copyir.com The temperature of the Fusing Rollers does not reach the required level even after the set period of time has elapsed during a warm copyir.comup cycle. 1 Check that the H1 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 2 Check that the H2 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80 copyir.com2 and copyir.com3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81 copyir.com2 and copyir.com3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB copyir.comA.
C3452 Fusing Warm copyir.comUp Failure (Sub)
copyir.com The Fusing Roller Sub Thermistor does not detect the required temperature within 30 sec. after a warm copyir.comup cycle has begun; therefore, the copier does not complete the warm copyir.comup cycle.
copyir.com The temperature of the Fusing Rollers does not reach the required level even after the set period of time has elapsed during a warm copyir.comup cycle. 1 Check that the H1 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 2 Check that the H2 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80 copyir.com2 and copyir.com3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81 copyir.com2 and copyir.com3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB copyir.comA.
C3751 High Fuser Temperature Failure (Main)
copyir.com The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature above 240 °C when the Main Power Switch is set to ON. 1 Check that the H1 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 2 Check that the H2 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80 copyir.com2 and copyir.com3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81 copyir.com2 and copyir.com3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB copyir.comA.
C3752 High Fuser Temperature Failure (Sub)
copyir.com The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature above 240 °C when the Main Power Switch is set to ON. 1 Check that the H1 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 2 Check that the H2 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80 copyir.com2 and copyir.com3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81 copyir.com2 and copyir.com3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB copyir.comA.
C3851 Low Fuser Temperature Failure (Main)
copyir.com The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below 105 °C during standby.
copyir.com The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below 105 °C during printing. 1 Check that the H1 comes on when the Right copyir.comSide Door is opened, then closed, and correct or replace as necessary. 2 Check that the H2 comes on when the Right copyir.comSide Door is opened, then closed, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80 copyir.com2 and copyir.com3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81 copyir.com2 and copyir.com3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB copyir.comA.
C3852 Low Fuser Temperature Failure (Sub)
copyir.com The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below 105 °C during standby.
copyir.com The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below 105 °C during printing. 1 Check that the H1 comes on when the Right copyir.comSide Door is opened, then closed, and correct or replace as necessary. 2 Check that the H2 comes on when the Right copyir.comSide Door is opened, then closed, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80 copyir.com2 and copyir.com3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81 copyir.com2 and copyir.com3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB copyir.comA.
C4001 Main body Communication Failure
Communications with the Mechanical Control Board and the MFBS Board/MFBS2 Board fail. 1 Check the MFBS/MFBS2 connector for proper connection, and correct as necessary. 2 Check the PWB copyir.comA connector for proper connection, and correct as necessary. 3 Check the flat cable between MFBS/MFBS2 and PWB copyir.comA for proper connection, and correct as necessary. 4 Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 5 Change MFBS/MFBS2. 6 Change PWB copyir.comA.
C4002 HSYNC Detection Failure
copyir.com No SOS falling edges are detected within the set period of time after laser emission began while the Polygon Motor is turning.
copyir.com No SOS falling edges are detected while VIA remains ON. 1 Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 2 Check the PH and the PWB copyir.comA connectors for proper connection, and correct as necessary. 3 Change PH. 4 Change PWB copyir.comA.
C4101 Polygon Motor Failure
copyir.com The Polygon Motor Lock signal could not be detected within the set period of time after the Polygon Motor is energized. (Faulty start detection)
copyir.com No First Lock signals are detected during the 1 copyir.com second period that starts 1 second after a First Lock signal. (Faulty lock signal detection)
copyir.com The Polygon Motor Lock signal could not be detected after the set period of time has elapsed while the Polygon Motor is turning. (Out copyir.comof copyir.comtiming lock detection)
copyir.com The Polygon Motor Lock signal is set to ON for longer than the set period of time while the Polygon Motor remains stopped. (Abnormal lock detection) 1 Check the PH connector for proper connection, and correct as necessary. 2 Change PH. 3 Change PWB copyir.comA.
C4721 Main Body G/A Communication Failure
copyir.com Communications with the gate array for expansion I/O (the IC mounted on the Mechanical Control Board) fail. 1 Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 2 Check each control board and the PWB copyir.comA for proper connection, and correct as necessary. 3 Change PWB copyir.comA.
C5102 Main Motor Failure
copyir.com The Transport Motor Lock signal remains set to H for a set period of time while the Transport Motor is turning. 1 Check the M1 connector for proper connection, and correct as necessary. 2 Check the M1 for proper drive coupling, and correct as necessary. 3 Check the PWB copyir.comA connector for proper connection and correct as necessary. 4 M1 operation check PWB copyir.comA PJ28A copyir.com4 (REM) M copyir.com4 5 Change PWB copyir.comA. 6 Change PU1.
C5351 Power Supply Cooling Fan Motor Failure
copyir.com The Power Supply Cooling Fan Motor Lock signal remains set to H for a set period of time while the Power Supply Cooling Fan Motor is turning.
copyir.com The Power Supply Cooling Fan Motor Lock signal remains set to L for a set period of time while the Power Supply Cooling Fan Motor remains stopped. 1 Check the M4 connectors for proper connection, and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 M4 operation check PWB copyir.comA PJ33A copyir.com1 (REM) D copyir.com5 4 Change PU1.
C5352 Cooling Fan Motor Failure
copyir.com The Cooling Fan Motor Lock signal remains set to H for a set period of time while the Cooling Fan Motor is turning.
copyir.com The Cooling Fan Motor Lock signal remains set to L for a set period of time while the Cooling Fan Motor remains stopped 1 Check the M5 connectors for proper connection, and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 M5 operation check. 4 Change PWB copyir.comA.
C5353 IU Cooling Fan Motor Failure
copyir.com The IU Cooling Fan Motor Lock signal remains set to H for a set period of time while the IU Cooling Fan Motor is turning.
copyir.com The IU Cooling Fan Motor Lock signal remains set to L for a set period of time while the IU Cooling Fan Motor remains stopped. 1 Check the M6 connectors for proper connection, and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 M6 operation check. 4 Change PWB copyir.comA.
C7001 Engine connection error
copyir.com The system fails in checking initial engine connection when the Power Switch is turned ON.
copyir.com The system succeeded in checking initial connection when the Power Switch was turned ON; then it fails in rechecking initial connection through the execution of a software reset when a communications error occurs during operation. 1 Check the connection between Mechanical Control Board and BCRS Board. 2 Reset the malfunction and turn OFF and ON the Power Switch. 3 Change BCRS. 4 Change PWB copyir.comA.
C8301 ADF Fan Motor Failure
copyir.com See DF copyir.com620 service manual.
C9701 ADF Document Size Failure Adjustment
copyir.com See DF copyir.com620 service manual.
CA052 MIO Device Failure
copyir.com The MIO device does not operate properly 1 Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 2 Check the BCRS connectors for proper connection, and correct as necessary. 3 Change BCRS.
CC153 Flash ROM Failure
copyir.com The Flash ROM data was determined to be faulty when the unit was turned on. 1 Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 2 The firmware data is overwritten. 3 Change PWB copyir.comA.
CC155 Exit Option Flash ROM Failure
copyir.com See FS copyir.com530/PU copyir.com501/OT copyir.com602 service manual.
CD004 HDD error
copyir.com When error occurs during deletion of HDD data. 1 Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 2 Check theHard Disk connector for proper connection and correct as necessary. 3 Reinstall the Hard Disk. 4 Change Hard Disk. 5 Change MFBS/MFBS2.