C0001    LCT Communication Failure
copyir.com Due to a software malfunction, etc., the time on the watchdog timer has run out and a reset is performed.
C0202    Tray 1 Elevator Failure
copyir.com The Lift   copyir.comUp Sensor is not unblocked even after the set period of time has elapsed after the paper lift up operation for the drawer has begun.    1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of each motor for proper drive coupling, and correct as necessary. 3 Check the PU1 connector for proper connection and correct as necessary. 4 PC6 I/O check. 5 PC12 I/O check. 6 PC114   copyir.comPF I/O check. 7 PC123   copyir.comPF I/O check. 8 M7 operation check. 9 M8 operation check. 10 M124   copyir.comPF operation check. 11 M125   copyir.comPF operation check. 12 Change PWB   copyir.comA. 13 Change PWB   copyir.comC2. 14 Change PU1.
C0204    Tray 2 Elevator Failure
copyir.com The Lift   copyir.comUp Sensor is not unblocked even after the set period of time has elapsed after the paper lift up operation for the drawer has begun.    1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of each motor for proper drive coupling, and correct as necessary. 3 Check the PU1 connector for proper connection and correct as necessary. 4 PC6 I/O check. 5 PC12 I/O check. 6 PC114   copyir.comPF I/O check. 7 PC123   copyir.comPF I/O check. 8 M7 operation check. 9 M8 operation check. 10 M124   copyir.comPF operation check. 11 M125   copyir.comPF operation check. 12 Change PWB   copyir.comA. 13 Change PWB   copyir.comC2. 14 Change PU1.
C0206    Tray 3 Elevator Failure
copyir.com The Lift   copyir.comUp Sensor is not unblocked even after the set period of time has elapsed after the paper lift up operation for the drawer has begun.    1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of each motor for proper drive coupling, and correct as necessary. 3 Check the PU1 connector for proper connection and correct as necessary. 4 PC6 I/O check. 5 PC12 I/O check. 6 PC114   copyir.comPF I/O check. 7 PC123   copyir.comPF I/O check. 8 M7 operation check. 9 M8 operation check. 10 M124   copyir.comPF operation check. 11 M125   copyir.comPF operation check. 12 Change PWB   copyir.comA. 13 Change PWB   copyir.comC2. 14 Change PU1.
C0208    Tray 4 Elevator Failure
copyir.com The Lift   copyir.comUp Sensor is not unblocked even after the set period of time has elapsed after the paper lift up operation for the drawer has begun.    1 Check the motor and sensor connectors for proper connection, and correct as necessary. 2 Check the connector of each motor for proper drive coupling, and correct as necessary. 3 Check the PU1 connector for proper connection and correct as necessary. 4 PC6 I/O check. 5 PC12 I/O check. 6 PC114   copyir.comPF I/O check. 7 PC123   copyir.comPF I/O check. 8 M7 operation check. 9 M8 operation check. 10 M124   copyir.comPF operation check. 11 M125   copyir.comPF operation check. 12 Change PWB   copyir.comA. 13 Change PWB   copyir.comC2. 14 Change PU1.
C0209    LCT Elevator Motor Failure
copyir.com The Elevator Motor Pulse Sensor (PC10   copyir.comLCT) cannot detect both edges of H/L even after the set period of time has elapsed while the Elevator Motor (M5   copyir.comLCT) is turning backward/forward (raise/lower).
C0211    Bypass Lifting Motion Failure
copyir.com The Bypass Lift Sensor (PC29) is not blocked or unblocked even after the set period of time has elapsed after the Bypass Pick   copyir.comUp Solenoid (SL3) is energized after the manual feed paper take   copyir.comup operation has begun.    1 Check the SL3 connector for proper connection and correct as necessary. 2 Check cam position.. 3 PC29 I/O check PWB   copyir.comA. 4 SL3 operation check. 5 Change PWB   copyir.comA.
C0212    LCT Ejection Failure
copyir.com See PC   copyir.com407 sevice manual
C0213    LCT Shift Gate Malfunction
copyir.com See PC   copyir.com407 sevice manual
C0214    LCT Shifting Failure
copyir.com See PC   copyir.com407 sevice manual
C0215    LCT Shift Motor Malfunction
copyir.com See PC   copyir.com407 sevice manual
C0701    Manual Paper Size Detection Adjustment Failure
copyir.com The control value of the Manual Paper Size Detection Unit does not fall within the specified range when an adjustment is made of manual paper size detection.    1 Check the VR1 connector for proper connection and correct as necessary. 2 Readjust the VR1. 3 Replace VR1. 4 Change PWB   copyir.comA.
C1080    Exit Option Communication Failure
copyir.com The connection status of a finishing option is changed after the copier has been turned on.    1 Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 2 Check the PWB   copyir.comA FN and the PWB   copyir.comA for proper connection, and correct as necessary. 3 Change PWB   copyir.comA FN. 4 Change PWB   copyir.comA.
C1183    Elevator Motor Ascent/Descent Drive Failure
copyir.com See FS   copyir.com530/ PU   copyir.com501/ OT   copyir.com602 service manual.
C1190    Aligning Plate 1 Drive Failure
copyir.com See FS   copyir.com530/ PU   copyir.com501/ OT   copyir.com602 service manual.
C1191    Aligning Plate 2 Drive Failure
copyir.com See FS   copyir.com530/ PU   copyir.com501/ OT   copyir.com602 service manual.
C11A0    Paper   copyir.comLifter Drive Failure
C11A1    Exit Roller Pressure/Retraction Failure
copyir.com See FS   copyir.com530/ PU   copyir.com501/ OT   copyir.com602 service manual.
C11A2    Saddle Exit Roller Pressure/ Retraction Failure
copyir.comSee SD   copyir.com507 service manual.
C11A3    Shutter Drive Failure
copyir.com See FS   copyir.com530/PU   copyir.com501/OT   copyir.com602 service manual.
C11A4    Saddle Exit Motor Failure
copyir.com See SD   copyir.com507 service manual.
C11A5    Saddle In & Out Guide Motor Failure
copyir.com    copyir.com See SD   copyir.com507 service manual.
C11A6    Saddle Layable Guide Motor Drive Failure
copyir.com See SD   copyir.com507 service manual.
C11B0    Staple Unit CD Drive Failure
copyir.com See FS   copyir.com530/PU   copyir.com501/OT   copyir.com602 service manual.
C11B2    Staple Drive Failure
copyir.com See FS   copyir.com530/PU   copyir.com501/OT   copyir.com602 service manual.
C11B5    Saddle Staple 1 Drive Failure
copyir.com See SD   copyir.com507 service manual.
C11B6    Saddle Staple 2 Drive Failure
copyir.com See SD   copyir.com507 service manual.
C11C0    Punch Cam Motor Unit Failure
copyir.com See FS   copyir.com530/PU   copyir.com501/OT   copyir.com602 service manual.
C11D0    Crease Motor Drive Failure
copyir.com See SD   copyir.com507 service manual.
C2211    IU Motor Failure
copyir.com The IU Motor Lock signal remains set to H for a set period of time while the IU Motor is turning.
copyir.com The IU Motor Lock signal remains set to L for a set period of time while the IU Motor remains stopped.    1 Check the M2 connector for proper connection and correct as necessary. 2 Check the M2 for proper drive coupling, and correct as necessary. 3 Check the PWB   copyir.comA connector for proper connection and correct as necessary. 4 M2 operation check PWB   copyir.comA PJ28A   copyir.com11 (REM) M   copyir.com4 5 Change PWB   copyir.comA. 6 Change PU1.
C2351    Toner Suction Fan Motor Failure
copyir.com The Toner Suction Fan Motor Lock signal remains set to H for a set period of time while the Toner Suction Fan Motor is turning.
copyir.com The Toner Suction Fan Motor Lock signal remains set to L for a set period of time while the Toner Suction Fan Motor remains stopped.    1 Check the M11 connector for proper connection and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 Check the PWB   copyir.comA connector for proper connection and correct as necessary. 4 M11 operation check PWB   copyir.comA PJ5A   copyir.com13 (REM) D   copyir.com14 5 Change PWB   copyir.comA. 6 Change PU1.
C2431    IU Fuse Blowing Failure
copyir.com The fuse is not blown even after the lapse of a predetermined period of time.    1 Check the UN2 connector for proper connection and correct as necessary. 2 Remove the Developing Unit from the IU, and then replace UN2. 3 Run F8. 4 Change PWB   copyir.comA. 5 Change PU1N.
C2557    ATDC Sensor Failure
copyir.com The scanning value of the ATDC Sensor is less than 7 % while the IU Motor is turning.
copyir.com The scanning value of the ATDC Sensor is more than 19 % while the IU Motor is turning.    1 Check the UN2 connector for proper connection and correct as necessary. 2 Remove the Developing Unit from the IU, and then replace UN2. 3 Run F8. 4 Change PWB   copyir.comA. 5 Change PU1N.
C255C    ATDC Adjustment Failure
copyir.com The adjustment of the ATDC control voltage could not be completed in the set period of time when function F8 is run.
copyir.com The ATDC control voltage was not within the range of 5.39 V to 8.15 V when function F8 is run.    1 Check the UN2 connector for proper connection and correct as necessary. 2 Remove the Developing Unit from the IU, and then replace UN2. 3 Run F8. 4 Change PWB   copyir.comA. 5 Change PU1N.
C2654    EEPROM Failure
copyir.com An EEPROM where no initial data is written is detected    1 Disconnect and then connect the power cord. Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 2 Check the EEPROM on the Mechanical Control Board for proper connection, and correct as necessary. 3 Change PWB   copyir.comA. 4 Change EEPROM.
C2702    Abnormal Image Transfer Voltage
copyir.com The image transfer voltage exceeds 100 V for the set period of time while the IU Motor remains stopped.    1 Check the installation of the Transfer Roller. 2 Change HV1
C3451    Fusing Warm   copyir.comUp Failure (Main)
copyir.com The Fusing Roller Thermistor does not detect the required temperature within 30 sec. after a warmup cycle has begun; therefore, the copier does not complete the warm   copyir.comup cycle.
copyir.com The temperature of the Fusing Rollers does not reach the required level even after the set period of time has elapsed during a warm   copyir.comup cycle.    1 Check that the H1 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 2 Check that the H2 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80   copyir.com2 and    copyir.com3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81   copyir.com2 and    copyir.com3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB   copyir.comA.
C3452    Fusing Warm   copyir.comUp Failure (Sub)
copyir.com The Fusing Roller Sub Thermistor does not detect the required temperature within 30 sec. after a warm   copyir.comup cycle has begun; therefore, the copier does not complete the warm   copyir.comup cycle.
copyir.com The temperature of the Fusing Rollers does not reach the required level even after the set period of time has elapsed during a warm   copyir.comup cycle.    1 Check that the H1 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 2 Check that the H2 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80   copyir.com2 and    copyir.com3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81   copyir.com2 and    copyir.com3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB   copyir.comA.
C3751    High Fuser Temperature Failure (Main)
copyir.com The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature above 240 °C when the Main Power Switch is set to ON.    1 Check that the H1 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 2 Check that the H2 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80   copyir.com2 and    copyir.com3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81   copyir.com2 and    copyir.com3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB   copyir.comA.
C3752    High Fuser Temperature Failure (Sub)
copyir.com The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature above 240 °C when the Main Power Switch is set to ON.    1 Check that the H1 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 2 Check that the H2 comes on when the Main Power Switch is set to ON, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80   copyir.com2 and    copyir.com3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81   copyir.com2 and    copyir.com3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB   copyir.comA.
C3851    Low Fuser Temperature Failure (Main)
copyir.com The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below 105 °C during standby.
copyir.com The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below 105 °C during printing.    1 Check that the H1 comes on when the Right   copyir.comSide Door is opened, then closed, and correct or replace as necessary. 2 Check that the H2 comes on when the Right   copyir.comSide Door is opened, then closed, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80   copyir.com2 and    copyir.com3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81   copyir.com2 and    copyir.com3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB   copyir.comA.
C3852    Low Fuser Temperature Failure (Sub)
copyir.com The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below 105 °C during standby.
copyir.com The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below 105 °C during printing.    1 Check that the H1 comes on when the Right   copyir.comSide Door is opened, then closed, and correct or replace as necessary. 2 Check that the H2 comes on when the Right   copyir.comSide Door is opened, then closed, and correct or replace as necessary. 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary. 4 Check the operation of the TH1. Remove CN80 (4P), and then check that the resistance across CN80   copyir.com2 and    copyir.com3 on the Thermistor is infinity. 5 Check the operation of the TH2. Remove CN81 (4P), and then check that the resistance across CN81   copyir.com2 and    copyir.com3 on the Thermistor is infinity. 6 Check the continuity of the H1. Correct or replace as necessary. 7 Check the continuity of the H2. Correct or replace as necessary. 8 Change PU1. 9 Change PWB   copyir.comA.
C4001    Main body Communication Failure
Communications with the Mechanical Control Board and the MFBS Board/MFBS2 Board fail.    1 Check the MFBS/MFBS2 connector for proper connection, and correct as necessary. 2 Check the PWB   copyir.comA connector for proper connection, and correct as necessary. 3 Check the flat cable between MFBS/MFBS2 and PWB   copyir.comA for proper connection, and correct as necessary. 4 Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 5 Change MFBS/MFBS2. 6 Change PWB   copyir.comA.
C4002    HSYNC Detection Failure
copyir.com No SOS falling edges are detected within the set period of time after laser emission began while the Polygon Motor is turning.
copyir.com No SOS falling edges are detected while VIA remains ON.    1 Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 2 Check the PH and the PWB   copyir.comA connectors for proper connection, and correct as necessary. 3 Change PH. 4 Change PWB   copyir.comA.
C4101    Polygon Motor Failure
copyir.com The Polygon Motor Lock signal could not be detected within the set period of time after the Polygon Motor is energized. (Faulty start detection)
copyir.com No First Lock signals are detected during the 1   copyir.com second period that starts 1 second after a First Lock signal. (Faulty lock signal detection)
copyir.com The Polygon Motor Lock signal could not be detected after the set period of time has elapsed while the Polygon Motor is turning. (Out   copyir.comof   copyir.comtiming lock detection)
copyir.com The Polygon Motor Lock signal is set to ON for longer than the set period of time while the Polygon Motor remains stopped. (Abnormal lock detection)    1 Check the PH connector for proper connection, and correct as necessary. 2 Change PH. 3 Change PWB   copyir.comA.
C4721    Main Body G/A Communication Failure
copyir.com Communications with the gate array for expansion I/O (the IC mounted on the Mechanical Control Board) fail.    1 Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 2 Check each control board and the PWB   copyir.comA for proper connection, and correct as necessary. 3 Change PWB   copyir.comA.
C5102    Main Motor Failure
copyir.com The Transport Motor Lock signal remains set to H for a set period of time while the Transport Motor is turning.    1 Check the M1 connector for proper connection, and correct as necessary. 2 Check the M1 for proper drive coupling, and correct as necessary. 3 Check the PWB   copyir.comA connector for proper connection and correct as necessary. 4 M1 operation check PWB   copyir.comA PJ28A   copyir.com4 (REM) M   copyir.com4 5 Change PWB   copyir.comA. 6 Change PU1.
C5351    Power Supply Cooling Fan Motor Failure
copyir.com The Power Supply Cooling Fan Motor Lock signal remains set to H for a set period of time while the Power Supply Cooling Fan Motor is turning.
copyir.com The Power Supply Cooling Fan Motor Lock signal remains set to L for a set period of time while the Power Supply Cooling Fan Motor remains stopped.    1 Check the M4 connectors for proper connection, and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 M4 operation check PWB   copyir.comA PJ33A   copyir.com1 (REM) D   copyir.com5 4 Change PU1.
C5352    Cooling Fan Motor Failure
copyir.com The Cooling Fan Motor Lock signal remains set to H for a set period of time while the Cooling Fan Motor is turning.
copyir.com The Cooling Fan Motor Lock signal remains set to L for a set period of time while the Cooling Fan Motor remains stopped    1 Check the M5 connectors for proper connection, and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 M5 operation check. 4 Change PWB   copyir.comA.
C5353    IU Cooling Fan Motor Failure
copyir.com The IU Cooling Fan Motor Lock signal remains set to H for a set period of time while the IU Cooling Fan Motor is turning.
copyir.com The IU Cooling Fan Motor Lock signal remains set to L for a set period of time while the IU Cooling Fan Motor remains stopped.    1 Check the M6 connectors for proper connection, and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 M6 operation check. 4 Change PWB   copyir.comA.
C7001    Engine connection error
copyir.com The system fails in checking initial engine connection when the Power Switch is turned ON.
copyir.com The system succeeded in checking initial connection when the Power Switch was turned ON; then it fails in rechecking initial connection through the execution of a software reset when a communications error occurs during operation.    1 Check the connection between Mechanical Control Board and BCRS Board. 2 Reset the malfunction and turn OFF and ON the Power Switch. 3 Change BCRS. 4 Change PWB   copyir.comA.
C8301    ADF Fan Motor Failure
copyir.com See DF   copyir.com620 service manual.
C9701    ADF Document Size Failure Adjustment
copyir.com See DF   copyir.com620 service manual.
CA052    MIO Device Failure
copyir.com The MIO device does not operate properly    1 Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 2 Check the BCRS connectors for proper connection, and correct as necessary. 3 Change BCRS.
CC153    Flash ROM Failure
copyir.com The Flash ROM data was determined to be faulty when the unit was turned on.    1 Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 2 The firmware data is overwritten. 3 Change PWB   copyir.comA.
CC155    Exit Option Flash ROM Failure
copyir.com See FS   copyir.com530/PU   copyir.com501/OT   copyir.com602 service manual.
CD004    HDD error
copyir.com When error occurs during deletion of HDD data.    1 Turn OFF the Main Power Switch, wait for 10 sec. or more, and turn ON the Main Power Switch. 2 Check theHard Disk connector for proper connection and correct as necessary. 3 Reinstall the Hard Disk. 4 Change Hard Disk. 5 Change MFBS/MFBS2.