C0211    Bypass tray up/down failure
– While the bypass lift sensor (PS2) is in the OFF state after the power is turned ON, output is finished, or a paper jam is cleared, PS2 is not turned ON within the given time after the bypass pick-up solenoid (SD1) has been turned ON    copyir.com Then SD1 is turned ON again, but PS2 cannot be turned ON within the given time    copyir.com
– When the bypass lift sensor (PS2) is in the ON state, PS2 is not turned OFF within the given time after the bypass pick-up solenoid (SD1) has been turned ON    copyir.com    1 Check the connector between M1-MFPB P006 for proper connection and correct as necessary    copyir.com 2 Check M1 for correct drive coupling and correct as necessary    copyir.com 3 Check the connector between CL1-relay CN3-relay CN6- MFPB P008 for proper connection and correct as necessary    copyir.com 4 CL1 operation check    copyir.com 5 Check the connector between SD1-relay CN4-relay CN6- MFPB P008 for proper connection and correct as necessary    copyir.com 6 M1 operation check    copyir.com 7 SD1 operation check    copyir.com 8 Change MFPB    copyir.com
C03FF    Faulty model setting
– “Model Setting” of “Adjust” available from the Service mode is incorrectly set    copyir.com
C2351    Cooling fan motor malfunction
– The fan lock signal remains HIGH for a predetermined continuous period of time while the cooling fan motor (FM2) is turning    copyir.com    1 Check the connector between FM2-relay CN27-MFPB P013 for proper connection and correct as necessary    copyir.com 2 Check the fan for possible overload and correct as necessary    copyir.com 3 FM2 operation check    copyir.com 4 Change MFPB    copyir.com
C2557    Abnormally low toner density detected TCR sensor board
– The T/C ratios detected by the TCR sensor board (TCRSB) are below the threshold for the detection of abnormally low T/C ratio for three successive times    copyir.com However, if a toner empty condition is detected, this abnormality is not detected    copyir.com    1 Check to see if developer is available    copyir.com 2 Check the connector between TCRSB-relay CN14-MFPB P010 for proper connection and correct as necessary    copyir.com 3 Change TCRSB    copyir.com 4 Change MFPB    copyir.com
C2558    Abnormally high toner density detected TCR sensor board
– The T/C ratios detected by the TCR sensor board (TCRSB) are above the threshold for the detection of abnormally high T/C ratio for three successive times    copyir.com
– The connector between MFPB to TCRSB is disconnected    copyir.com    1 Check to see if developer is available    copyir.com 2 Check the connector between TCRSB-relay CN14-MFPB P010 for proper connection and correct as necessary    copyir.com 3 Change TCRSB    copyir.com 4 Change MFPB    copyir.com
C255C    TCR sensor board adjustment failure
– When TCR AUTO ADJUST is performed, the difference between the TCR sensor output voltage determined by TCR AUTO ADJUST and the standard voltage is greater than the threshold value    copyir.com    1 Check to see if developer is available    copyir.com 2 Check the connector between TCRSB-relay CN14-MFPB P010 for proper connection and correct as necessary    copyir.com 3 Change TCRSB    copyir.com 4 Change MFPB    copyir.com
C2702    Abnormal image transfer voltage (HV)
– The image transfer voltage remains more than 100 V continuously for a given period of time while the drum remains stationary    copyir.com    1 Check the transfer roller unit for installation    copyir.com 2 Change HV1    copyir.com 3 Change MFPB    copyir.com
C3451    Warming-up failure
– The thermistor/1 (TH1) detected that the temperature of the surface of the fusing roller did not reach the specified level even after the lapse of given period of time has passed during warm-up    copyir.com    1 Check the fusing unit for correct installation    copyir.com 2 Check the open/close operation of the right door    copyir.com 3 Check the fusing unit, DCPU and MFPB for proper connection and correct or change as necessary    copyir.com 4 Change fusing unit    copyir.com 5 Change MFPB    copyir.com 6 Change DCPU    copyir.com
C3452    Warming-up failure (sub)
– The thermistor/2 (TH2) detected that the temperature of the surface of the fusing roller did not reach the specified level even after the lapse of given period of time has passed during warm-up    copyir.com    1 Check the fusing unit for correct installation    copyir.com 2 Check the open/close operation of the right door    copyir.com 3 Check the fusing unit, DCPU and MFPB for proper connection and correct or change as necessary    copyir.com 4 Change fusing unit    copyir.com 5 Change MFPB    copyir.com 6 Change DCPU    copyir.com
C3751    Abnormally high fusing temperature (main)
– The temperature detected by the thermistor/1 (TH1) is over the specified temperature for more than the specified period of time after power is turned ON    copyir.com    1 Check the fusing unit for correct installation    copyir.com 2 Check the open/close operation of the right door    copyir.com 3 Check the fusing unit, DCPU and MFPB for proper connection and correct or change as necessary    copyir.com 4 Change fusing unit    copyir.com 5 Change MFPB    copyir.com 6 Change DCPU    copyir.com
C3752    Abnormally high fusing temperature (sub)
– The temperature detected by the thermistor/2 (TH2) is over the specified temperature for more than the specified period of time after power is turned ON    copyir.com    1 Check the fusing unit for correct installation    copyir.com 2 Check the open/close operation of the right door    copyir.com 3 Check the fusing unit, DCPU and MFPB for proper connection and correct or change as necessary    copyir.com 4 Change fusing unit    copyir.com 5 Change MFPB    copyir.com 6 Change DCPU    copyir.com
C3851    Abnormally low fusing temperature (main)
– The temperature detected by the thermistor/1 (TH1) is below the specified temperature for more than the specified period of time    copyir.com    1 Check the fusing unit for correct installation    copyir.com 2 Check the open/close operation of the right door    copyir.com 3 Check the fusing unit, DCPU and MFPB for proper connection and correct or change as necessary    copyir.com 4 Change fusing unit    copyir.com 5 Change MFPB    copyir.com 6 Change DCPU    copyir.com
C3852    Abnormally low fusing temperature (sub)
– The temperature detected by the thermistor/2 (TH2) is below the specified temperature for more than the specified period of time    copyir.com    1 Check the fusing unit for correct installation    copyir.com 2 Check the open/close operation of the right door    copyir.com 3 Check the fusing unit, DCPU and MFPB for proper connection and correct or change as necessary    copyir.com 4 Change fusing unit    copyir.com 5 Change MFPB    copyir.com 6 Change DCPU    copyir.com
C4001    Faulty HSYNC (SOS)
– The SOS sensor does not detect a rising edge of SOS within a given period of time after the polygon motor has started turning and a laser output has been started    copyir.com
– The SOS sensor detects no falling edges of SOS while VIA (image area control) is ON    copyir.com    1 Turn OFF and ON the power switch    copyir.com 2 Check the connector between PH unit-MFPB P001, P002 for proper connection and correct as necessary    copyir.com 3 Change PH unit    copyir.com 4 Change MFPB    copyir.com
C4101    Polygon motor rotation malfunction
– A HIGH polygon motor lock signal is not detected within a given period of time that begins 0    copyir.com5 sec    copyir.com after the polygon motor has started turning    copyir.com
– A LOW polygon motor lock signal is detected for a continuous given period of time while the rotation of the polygon motor remains stabilized    copyir.com    1 Turn OFF and ON the power switch    copyir.com 2 Check the connector between PH unit-MFPB P001, P002 for proper connection and correct as necessary    copyir.com 3 Change PH unit    copyir.com 4 Change MFPB    copyir.com
C5102    Main motor malfunction
– The main motor (M1) lock signal remains HIGH for a continuous 1-sec    copyir.com period after 1- sec    copyir.com after the main motor has started turning    copyir.com    1 Check the connector between M1-MFPB P006 for proper connection and correct as necessary    copyir.com 2 Check M1 for correct drive coupling and correct as necessary    copyir.com 3 M1 operation check    copyir.com 4 Change MFPB    copyir.com 5 Change DCPU
C5351    Fusing cooling fan motor malfunction
– The fan lock signal remains HIGH for a predetermined continuous period of time while the fusing cooling fan motor (FM1) is turning    copyir.com    1 Check the connector between FM1-relay CN42-relay CN13-MFPB P013 for proper connection and correct as necessary    copyir.com 2 Check the fan for possible overload and correct as necessary    copyir.com 3 FM1 operation check    copyir.com 4 Change MFPB    copyir.com
C6101    Scanner home detection failure
– When the power switch is turned ON or a scan operation is completed, detecting the home position fails    copyir.com    1 Turn OFF and ON the power switch    copyir.com 2 Check the connector between M3-MFPB P101 for proper connection and correct as necessary    copyir.com 3 Check M3 for correct drive coupling and correct as necessary    copyir.com 4 Check the connector between CIS-MFPB P102 for proper connection and correct as necessary    copyir.com 5 M3 operation check    copyir.com 6 Change M3    copyir.com 7 Change CIS    copyir.com 8 Change MFPB    copyir.com
C9401    IR exposure lamp malfunction
– When the power switch is turned ON or a scan operation is completed, the light quantity is checked and the shading compensation is performed    copyir.com At this time, trouble is detected    copyir.com    1 Turn OFF and ON the power switch    copyir.com 2 Check the connector between CIS-MFPB P102 for proper connection and correct as necessary    copyir.com 3 Change CIS 4 Change MFPB    copyir.com
CC151    Flash ROM error
– The copier determines that there is an error if writing to the flash ROM fails during upgrading of the firmware    copyir.com
– When the power switch is turned ON, the error indicator lights up steadily and a corresponding message appears on the display    copyir.com
– If this error message appears, no operations can then be performed    copyir.com It is not possible to upgrade the firmware from a PC connected through USB connection, either    copyir.com    1 Check the MFPB connectors for proper connection and correct as necessary    copyir.com 2 Identify the specific firmware that is responsible for the error    copyir.com 3 Perform upgrading of the firmware    copyir.com 4 Change MFPB    copyir.com
CC153    Engine flash ROM error
– Data of flash ROM of the engine control system is determined to be faulty    copyir.com    1 Check the MFPB connectors for proper connection and correct as necessary    copyir.com 2 Identify the specific firmware that is responsible for the error    copyir.com 3 Perform upgrading of the firmware    copyir.com 4 Change MFPB    copyir.com
CC163    Engine connection failure
– The controller can not communicate with the engine control system    copyir.com
– Incorrect engine firmware is installed    copyir.com    1 Turn OFF and ON the power switch    copyir.com 2 Check whether the correct engine firmware is installed    copyir.com If not, rewrite the firmware    copyir.com J    copyir.com1    copyir.com Rewriting of firmware 3 Check the MFPB connectors for proper connection and correct as necessary    copyir.com 4 Change MFPB    copyir.com
CD301    EEPROM error
– Contact the responsible people of KMBT before taking some countermeasures    copyir.com  