C0001    LCT connection failed
C0204    Tray 2 feeder up/down abnormality
C0206    Tray 3 feeder up/down abnormality
C0208    Tray 4 feeder up/down abnormality
C0209    LCT elevator motor malfunction
C0210    LCT ascent motion failure
C0211    Manual feed up/down abnormality
C0212    LCT ejection failure
C0213    LCT shift gate malfunction
C0214    LCT shifting failure
C0215    LCT shift motor malfunction
C0301    Suction fan motor’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the FM10 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM10 operation check   copyir.com 4 Change the right door assy   copyir.com 5 Change PRCB   copyir.com
C1004    FNS communication error
C1182    Shift motor mechanism failure
C11A1    Finishing option exit roller pressure/retraction failure
C11E0    Route switch malfunction
C2151    Secondary transfer roller pressure welding alienation
• During a retraction operation of the 2nd image transfer roller, the 2nd image transfer welding alienation sensor cannot detect the 2nd image transfer roller at its retracted position within a predetermined period of time after the 2nd image transfer retraction motor starts rotating   copyir.com
• During a pressure operation of the 2nd image transfer roller, the 2nd image transfer welding alienation sensor cannot detect the 2nd image transfer roller at its pressed position within a predetermined period of time after the 2nd image transfer retraction motor starts rotating   copyir.com    1 Check the M5 connector for proper connection and correct as necessary   copyir.com 2 Check the connector of M5 for proper drive coupling and correct as necessary   copyir.com 3 PS36 I/O check, sensor check   copyir.com 4 Change the right door assy   copyir.com 5 Change PRCB   copyir.com
C2152    Transfer belt pressure welding alienation
• During a retraction operation of the transfer belt, the transfer belt retraction sensor cannot detect the transfer belt at its retracted position within a predetermined period of time after the transfer belt retraction clutch is turned ON   copyir.com
• During a pressure operation of the transfer belt, the transfer belt retraction sensor cannot detect the transfer belt at its pressed position within a predetermined period of time after the transfer belt clutch is turned ON   copyir.com    1 Check the M5 connector for proper connection and correct as necessary   copyir.com 2 PS6 I/O check, sensor check   copyir.com 3 CL3 operation check   copyir.com 4 M2 operation check   copyir.com 5 Change CL3   copyir.com 6 Change M2   copyir.com 7 Change PRCB   copyir.com
C2164    PC charge malfunction
• When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time   copyir.com    1 Check the imaging unit for proper connection and correct as necessary   copyir.com 2 Check the HV connector for proper connection and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 Change IU   copyir.com 5 Change HV   copyir.com 6 Change PRCB   copyir.com
C2253    Color PC motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning   copyir.com    1 Check the M3 connector for proper connection and correct as necessary   copyir.com 2 Check the M3 connector for proper drive coupling and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 M3 operation check   copyir.com 5 Change M2   copyir.com 6 Change PRCB   copyir.com
C2254    Color PC motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the M3 connector for proper connection and correct as necessary   copyir.com 2 Check the M3 connector for proper drive coupling and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 M3 operation check   copyir.com 5 Change M2   copyir.com 6 Change PRCB   copyir.com
C225D    Color dev   copyir.com unit engagement/ disengagement failure
• The gears remain disengaged after the lapse of a predetermined period of time after the engagement operation is started by the color dev   copyir.com unit engaged motor   copyir.com
• The gears remain engaged after the lapse of a predetermined period of time after the disengagement operation is started by the color dev   copyir.com unit engaged motor   copyir.com    1 Check the M4 connector for proper connection and correct as necessary   copyir.com 2 Check the M4 connector for proper drive coupling and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 PS19 I/O check, sensor check   copyir.com 5 M4 operation check   copyir.com 6 Change M4   copyir.com 7 Change PRCB   copyir.com
C2451    Release new transfer belt unit
• A new installation is not detected when a new transfer cleaner unit (image transfer belt unit) is installed   copyir.com    1 Reinstall unit   copyir.com 2 Check there is a short circuit in the fuse of the transfer belt unit   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 Change PRCB   copyir.com
C2551    Abnormally low toner density detected cyan TCR sensor
• TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 4 % or less for a given number of times consecutively   copyir.com    1 Reinstall imaging unit   copyir.com 2 Reinstall toner cartridge   copyir.com 3 M6 operation check (At this time, IU must be non-installation   copyir.com)   copyir.com 4 M7 operation check (At this time, IU must be non-installation   copyir.com)   copyir.com 5 Change imaging unit   copyir.com 6 Change PRCB   copyir.com
C2552    Abnormally high toner density detected cyan TCR sensor
• TC ratio in the developing machine, which is determined by Toner replenishing amount control mechanism, is 11 % or more for a given number of times consecutively   copyir.com
• When the connector of the TCR sensor is disconnected   copyir.com    1 Reinstall imaging unit   copyir.com 2 Reinstall toner cartridge   copyir.com 3 Change imaging unit   copyir.com 4 Change PRCB   copyir.com
C2553    Abnormally low toner density detected magenta TCR sensor
• TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 4 % or less for a given number of times consecutively   copyir.com    1 Reinstall imaging unit   copyir.com 2 Reinstall toner cartridge   copyir.com 3 M6 operation check (At this time, IU must be non-installation   copyir.com)   copyir.com 4 M7 operation check (At this time, IU must be non-installation   copyir.com)   copyir.com 5 Change imaging unit   copyir.com 6 Change PRCB   copyir.com
C2554    Abnormally high toner density detected magenta TCR sensor
• TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 11 % or more for a given number of times consecutively   copyir.com • When the connector of the TCR sensor is disconnected   copyir.com    1 Reinstall imaging unit   copyir.com 2 Reinstall toner cartridge   copyir.com 3 Change imaging unit   copyir.com 4 Change PRCB   copyir.com
C2555    Abnormally low toner density detected yellow TCR sensor
• TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 4 % or less for a given number of times consecutively   copyir.com    1 Reinstall imaging unit   copyir.com 2 Reinstall toner cartridge   copyir.com 3 M6 operation check (At this time, IU must be non-installation   copyir.com)   copyir.com 4 M7 operation check (At this time, IU must be non-installation   copyir.com)   copyir.com 5 Change imaging unit   copyir.com 6 Change PRCB   copyir.com
C2556    Abnormally high toner density detected yellow TCR sensor
• TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 11 % or more for a given number of times consecutively   copyir.com
• When the connector of the TCR sensor is disconnected   copyir.com    1 Reinstall imaging unit   copyir.com 2 Reinstall toner cartridge   copyir.com 3 Change imaging unit   copyir.com 4 Change PRCB   copyir.com
C2557    Abnormally low toner density detected black TCR sensor
• TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 4 % or less for a given number of times consecutively   copyir.com    1 M7 operation check (At this time, IU must be non-installation   copyir.com)   copyir.com 2 Reinstall imaging unit   copyir.com 3 Reinstall toner cartridge   copyir.com 4 Change imaging unit /K   copyir.com 5 Change PRCB   copyir.com
C2558    Abnormally high toner density detected black TCR sensor
• TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 11 % or more for a given number of times consecutively   copyir.com
• When the connector of the TCR sensor is disconnected   copyir.com    1 Reinstall imaging unit   copyir.com 2 Reinstall toner cartridge   copyir.com 3 Change imaging unit/K   copyir.com 4 Change PRCB   copyir.com
C2559    Cyan TCR sensor adjustment failure
• TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value   copyir.com    1 Reinstall imaging unit   copyir.com 2 Change imaging unit   copyir.com 3 Change PRCB   copyir.com
C255A    Magenta TCR sensor adjustment failure
• TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value   copyir.com    1 Reinstall imaging unit   copyir.com 2 Change imaging unit   copyir.com 3 Change PRCB   copyir.com
C255B    Yellow TCR sensor adjustment failure
• TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value   copyir.com    1 Reinstall imaging unit   copyir.com 2 Change imaging unit   copyir.com 3 Change PRCB   copyir.com
C255C    Black TCR sensor adjustment failure
• TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value   copyir.com    1 Reinstall imaging unit /K   copyir.com 2 Change imaging unit /K   copyir.com 3 Change PRCB   copyir.com
C2650    Main backup media access error
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error   copyir.com
• The error was found when reading out the counter value   copyir.com
• The machine detects that the service EEPROM board is not loaded in position   copyir.com    1 Check the connector (CN36) on PRCB, the connector (CN1) on SVERB, and the harness between the boards for proper connection and correct as necessary   copyir.com 2 Change PRCB 2   copyir.com1   copyir.com Turn OFF the main power switch and replace the current PRCB with a new one   copyir.com (When using a PRCB of another machine in service, be sure to use a PRCB installed in the same model   copyir.com) 2   copyir.com2   copyir.com Update the PRCB firmware   copyir.com 3   copyir.com After completing the firmware update, turn OFF and ON the main power switch and check to see that warm-up is started   copyir.com Make sure that malfunction codes other than C2650 or improper IU/TC placement is not detected   copyir.com 4   copyir.com When the trouble cannot be solved, reinstall the removed PRCB to the original board   copyir.com NOTE • When taking the above steps, check whether PRCB is defective or not without replacing the SVERB   copyir.com 3 Change SVERB 3   copyir.com1   copyir.com Replace the current SVERB with a new one   copyir.com 3   copyir.com2   copyir.com Turn ON the main power switch and check to see that warm-up is started   copyir.com (One minute is spent to prepare the new SVERB for use   copyir.com During the period, the control panel backlight stays off   copyir.com) Make sure that malfunction codes other than C2650 or improper IU/TC placement 3   copyir.com3   copyir.com Make the specified readjustments   copyir.com 4 If the above actions do not solve the problem, contact KMBT   copyir.com
C2651    EEPROM access error (IU C)
• An error was found when reading or writing data   copyir.com
• The error was found when reading out the counter value   copyir.com    1 Clean the connection between the imaging unit and the machine if dirty 2 Reinstall imaging unit   copyir.com 3 Check the harness for proper connection and correct as necessary   copyir.com 4 Change imaging unit   copyir.com 5 Change PRCB   copyir.com
C2652    EEPROM access error (IU M)
• An error was found when reading or writing data   copyir.com
• The error was found when reading out the counter value   copyir.com    1 Clean the connection between the imaging unit and the machine if dirty 2 Reinstall imaging unit   copyir.com 3 Check the harness for proper connection and correct as necessary   copyir.com 4 Change imaging unit   copyir.com 5 Change PRCB   copyir.com
C2653    EEPROM access error (IU Y)
• An error was found when reading or writing data   copyir.com
• The error was found when reading out the counter value   copyir.com    1 Clean the connection between the imaging unit and the machine if dirty 2 Reinstall imaging unit   copyir.com 3 Check the harness for proper connection and correct as necessary   copyir.com 4 Change imaging unit   copyir.com 5 Change PRCB   copyir.com
C2654    EEPROM access error (IU K)
• An error was found when reading or writing data   copyir.com
• The error was found when reading out the counter value   copyir.com    1 Clean the connection between the imaging unit and the machine if dirty 2 Reinstall imaging unit   copyir.com 3 Check the harness for proper connection and correct as necessary   copyir.com 4 Change imaging unit   copyir.com 5 Change PRCB   copyir.com
C2A01    EEPROM access error (TC C)
• An error was found when reading or writing data   copyir.com
• The error was found when reading out the counter value   copyir.com    1 Clean the connection between the toner cartridge and the machine if dirty   copyir.com 2 Reinstall toner cartridge   copyir.com 3 Check the harness for proper connection and correct as necessary   copyir.com 4 Change toner cartridge   copyir.com 5 Change PRCB   copyir.com
C2A02    EEPROM access error (TC M)
• An error was found when reading or writing data   copyir.com
• The error was found when reading out the counter value   copyir.com    1 Clean the connection between the toner cartridge and the machine if dirty   copyir.com 2 Reinstall toner cartridge   copyir.com 3 Check the harness for proper connection and correct as necessary   copyir.com 4 Change toner cartridge   copyir.com 5 Change PRCB   copyir.com
C2A03    EEPROM access error (TC Y)
• An error was found when reading or writing data   copyir.com
• The error was found when reading out the counter value   copyir.com    1 Clean the connection between the toner cartridge and the machine if dirty   copyir.com 2 Reinstall toner cartridge   copyir.com 3 Check the harness for proper connection and correct as necessary   copyir.com 4 Change toner cartridge   copyir.com 5 Change PRCB   copyir.com
C2A04    EEPROM access error (TC K)
• An error was found when reading or writing data   copyir.com
• The error was found when reading out the counter value   copyir.com    1 Clean the connection between the toner cartridge and the machine if dirty   copyir.com 2 Reinstall toner cartridge   copyir.com 3 Check the harness for proper connection and correct as necessary   copyir.com 4 Change toner cartridge   copyir.com 5 Change PRCB   copyir.com
C3101    Fusing roller separation failure
• With the fusing roller being retracted, the pulse of the fusing roller retraction sensor does not change even after the specified period of time has passed after the fusing retraction motor started rotating   copyir.com
• With the fusing roller being pressed, the pulse of the roller retraction sensor does not change even after the specified period of time has passed after the fusing retraction motor started rotating   copyir.com
• During a pressure operation of the fusing roller, the fusing roller is not at the pressed position even after the roller retraction sensor counts the specified number of pulses after the fusing retraction motor starts rotating   copyir.com    1 Check the M12 connector for proper connection and correct as necessary   copyir.com 2 PS38 I/O check, sensor check   copyir.com 3 M12 operation check   copyir.com 4 Change M12   copyir.com 5 Change fu
C3201    Fusing motor failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the M2 connector for proper connection and correct as necessary   copyir.com 2 Check the loading status of the fusing unit drive, and correct the error as necessary   copyir.com 3 Check the fusing unit, PRCB for proper connection and correct or change as necessary   copyir.com 4 M2 operation check   copyir.com 5 Change M2   copyir.com 6 Change PRCB   copyir.com
C3202    Fusing motor turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the M2 connector for proper connection and correct as necessary   copyir.com 2 Check the loading status of the fusing unit drive, and correct the error as necessary   copyir.com 3 Check the fusing unit, PRCB for proper connection and correct or change as necessary   copyir.com 4 M2 operation check   copyir.com 5 Change M2   copyir.com 6 Change PRCB   copyir.com
C3301    Fusing cooling fan motor/1 failure to turn
• The fan motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the FM13 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM13 operation check   copyir.com 4 Change FM13   copyir.com 5 Change PRCB   copyir.com
C3302    Fusing cooling fan motor/2,3 failure to turn
• The fan motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the FM11 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM11 operation check   copyir.com 4 Change FM11   copyir.com 5 Change PRCB   copyir.com
C3421    Fusing heaters trouble (heating side)
• The temperature detected by the heating roller thermistor/C does not reach a predetermined level after the lapse of a predetermined period of time after the heating roller fusing heater lamp lights up   copyir.com
• The difference between the maximum and minimum temperatures detected by the heating roller thermistor/C within a predetermined period of time after the start of a warm-up cycle is below or above a predetermined value   copyir.com
• The temperature detected after a pressure level correction remains under a predetermined level even after the lapse of a predetermined period of time after the start of the temperature detection   copyir.com
• During a warm-up, a zero cross signal cannot be detected after the lapse of a predetermined period of time after the fusing heater is turned ON or OFF   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, PRCB and DCPU for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change PRCB   copyir.com 6 Change DCPU   copyir.com
C3423    Fusing heaters trouble (pressurizing side)
• After warm-up operation starts, the fusing pressure roller thermistor does not detect a temperature as high as a predetermined one though a predetermined period of time has elapsed   copyir.com
• The temperature of the pressure roller remains lower than a predetermined level even after the lapse of a predetermined period of time after a temperature correction   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, PRCB and DCPU for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change PRCB   copyir.com 6 Change DCPU   copyir.com
C3721    Fusing abnormally high temperature detection (heating side)
• The heating roller thermistor continues to detect a temperature higher than a predetermined one for a predetermined period of time   copyir.com
• Hard protection signal L is detected continuously over a predetermined period of time   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, PRCB and DCPU for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change PRCB   copyir.com 6 Change DCPU   copyir.com
C3723    Fusing abnormally high temperature detection (pressurizing side)
• The temperature of the pressure roller continues to be higher than a predetermined level for a predetermined period of time after a temperature correction   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, PRCB and DCPU for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change PRCB   copyir.com 6 Change DCPU   copyir.com
C3821    Fusing abnormally low temperature detection (heating side)
• The heating roller thermistor continues to detect a temperature lower than a predetermined one for a predetermined period of time   copyir.com
• In the states other than a warm-up operation, a zero cross signal cannot be detected after the lapse of a predetermined period of time after the fusing heater is turned ON or OFF   copyir.com
• The power supply frequency cannot be detected   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, PRCB and DCPU for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change PRCB   copyir.com 6 Change DCPU   copyir.com
C3823    Fusing abnormally low temperature detection (pressurizing side)
• The temperature of the pressure roller continues to be lower than a predetermined level for a predetermined period of time after a temperature correction   copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)   copyir.com 2 Check the open/close operation of the upper right door   copyir.com 3 Check the fusing unit, PRCB and DCPU for proper connection and correct or change as necessary   copyir.com 4 Change fusing unit   copyir.com 5 Change PRCB   copyir.com 6 Change DCPU   copyir.com
C4151    Polygon motor rotation trouble (C)
• The polygon motor fails to turn stably even after the lapse of a given period of time after activating the polygon motor   copyir.com
• Motor lock signal detects HIGH for a given period time consecutively during the polygon motor is rotating   copyir.com    1 Check the connector for proper connection and correct as necessary   copyir.com 2 Change PH unit   copyir.com 3 Change REYB/PH   copyir.com 4 Change PRCB   copyir.com
C4152    Polygon motor rotation trouble (M)
• The polygon motor fails to turn stably even after the lapse of a given period of time after activating the polygon motor   copyir.com
• Motor lock signal detects HIGH for a given period time consecutively during the polygon motor is rotating   copyir.com    1 Check the connector for proper connection and correct as necessary   copyir.com 2 Change PH unit   copyir.com 3 Change REYB/PH   copyir.com 4 Change PRCB   copyir.com
C4153    Polygon motor rotation trouble (Y)
• The polygon motor fails to turn stably even after the lapse of a given period of time after activating the polygon motor   copyir.com
• Motor lock signal detects HIGH for a given period time consecutively during the polygon motor is rotating   copyir.com    1 Check the connector for proper connection and correct as necessary   copyir.com 2 Change PH unit   copyir.com 3 Change REYB/PH   copyir.com 4 Change PRCB   copyir.com
C4154    Polygon motor rotation trouble (K)
• The polygon motor fails to turn stably even after the lapse of a given period of time after activating the polygon motor   copyir.com
• Motor lock signal detects HIGH for a given period time consecutively during the polygon motor is rotating   copyir.com    1 Check the connector for proper connection and correct as necessary   copyir.com 2 Change PH unit   copyir.com 3 Change REYB/PH   copyir.com 4 Change PRCB   copyir.com
C4551    Laser malfunction (C)
• SOS signal is not detected even after the lapse of a given period of time after staring the laser output   copyir.com
• SOS signal is not detected for a given period of time during printing or image stabilization adjustment   copyir.com    1 Check the connector for proper connection and correct as necessary   copyir.com 2 Change PH unit   copyir.com 3 Change REYBPH   copyir.com 4 Change PRCB   copyir.com
C4552    Laser malfunction (M)
• SOS signal is not detected even after the lapse of a given period of time after staring the laser output   copyir.com
• SOS signal is not detected for a given period of time during printing or image stabilization adjustment   copyir.com    1 Check the connector for proper connection and correct as necessary   copyir.com 2 Change PH unit   copyir.com 3 Change REYBPH   copyir.com 4 Change PRCB   copyir.com
C4553    Laser malfunction (Y)
• SOS signal is not detected even after the lapse of a given period of time after staring the laser output   copyir.com
• SOS signal is not detected for a given period of time during printing or image stabilization adjustment   copyir.com    1 Check the connector for proper connection and correct as necessary   copyir.com 2 Change PH unit   copyir.com 3 Change REYBPH   copyir.com 4 Change PRCB   copyir.com
C4554    Laser malfunction (K)
• SOS signal is not detected even after the lapse of a given period of time after staring the laser output   copyir.com
• SOS signal is not detected for a given period of time during printing or image stabilization adjustment   copyir.com    1 Check the connector for proper connection and correct as necessary   copyir.com 2 Change PH unit   copyir.com 3 Change REYBPH   copyir.com 4 Change PRCB   copyir.com
C5102    Transport motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the M1 connector for proper connection and correct as necessary   copyir.com 2 Check M1 for proper drive coupling and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 M1 operation check   copyir.com 5 Change M1   copyir.com 6 Change PRCB   copyir.com
C5103    Transport motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the M1 connector for proper connection and correct as necessary   copyir.com 2 Check M1 for proper drive coupling and correct as necessary   copyir.com 3 Check the PRCB connector for proper connection and correct as necessary   copyir.com 4 M1 operation check   copyir.com 5 Change M1   copyir.com 6 Change PRCB   copyir.com
C5351    Power supply cooling fan motor/1’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the FM8 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM8 operation check   copyir.com 4 Change FM8   copyir.com 5 Change DCPU   copyir.com 6 Change PRCB   copyir.com
C5354    Exhaust fan motor’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the FM14 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM14 operation check   copyir.com 4 Change FM14   copyir.com 5 Change PRCB   copyir.com
C5357    Cooling fan motor/1’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary   copyir.com    1 Check the FM16 connector for proper connection and correct as necessary   copyir.com 2 Check the fan for possible overload and correct as necessary   copyir.com 3 FM16 operation check   copyir.com 4 Change FM16   copyir.com 5 Change PRCB   copyir.com
C6102    Drive system home sensor malfunction
• The home position sensor (PS201) is defective or the exposure unit operates erratically   copyir.com    1 Correct or change the scanner drive (wire, pulley, gear, belt) if it is faulty   copyir.com 2 Correct the scanner motor set screw if loose   copyir.com 3 Check the PS201, M201 and BCRUB connector for proper connection and correct as necessary   copyir.com 4 PS201 I/O check, sensor check   copyir.com 5 M201 operation check   copyir.com 6 Change M201   copyir.com 7 Change BCRUB   copyir.com
C6401    Other troubles of scanner
• The scan operation was terminated abnormally because of a reason except defined trouble   copyir.com    1 Check the connectors between BCRUB and MFBUB for proper connection and correct as necessary   copyir.com 2 Change BCRUB   copyir.com 3 Change MFBUB   copyir.com 4 Change exposure unitk   copyir.com
C6704    Image input time out
• The scan motion is not completed even after the lapse of a predetermined period of time because of a hardware failure or other reason   copyir.com    1 Check the connectors between BCRUB and MFBUB for proper connection and correct as necessary   copyir.com 2 Change BCRUB   copyir.com 3 Change MFBUB   copyir.com 4 Change exposure unit   copyir.com
C6751    CCD clamp/gain adjustment failure
• The automatic gain control fails to converge when the main unit is started or a scan motion is started (the exposure unit does not move to the white reference position, or the automatic gain control is not properly completed as a result of a hardware failure)   copyir.com    1 Correct the harness connection between CCDUB and BCRUB if faulty   copyir.com 2 Check for possible extraneous light and correct as necessary   copyir.com 3 Clean the lens, mirrors, CCD surface, and shading sheet if dirty 4 Correct reflective mirror of the scanner if faulty, or change scanner   copyir.com 5 Change BCRUB   copyir.com 6 Change exposure unit   copyir.com
CC151    ROM contents error upon start-up
• A fault detected in a sequence of ROM contents check of the printer control board during starting   copyir.com    1 Restart the machine   copyir.com 2 Check the ROM version   copyir.com 3 Rewrite the firmware   copyir.com 4 Change PRCB   copyir.com
CC155    Finisher ROM error  