کو نیکا مینولتا 7828
C0002 Paper feed communication error
When the printer control board (PRCB) is receiving data, a communication error is detected copyir.com 1 Turn OFF the main power switch, disconnect and then connect the power cord copyir.com Wait for 10 sec copyir.com or more after connect the power cord, and turn ON the main power switch copyir.com 2 Rewrite the firmware copyir.com 3 Replace PRCB copyir.com
C0106 Tray 3/LCT paper feed motor turning at abnormal timing
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary copyir.com • The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary copyir.com When PC-110 or PC-210 is installed: 1 Check the connector between M111-PCCB CN5 for proper connection and correct as necessary copyir.com 2 Check the connector of M111 for proper drive coupling and correct as necessary copyir.com 3 M111 operation check PCCB CN5-5 (CW/CCW) PC-110/PC-210 4-C copyir.com 4 Replace M111 copyir.com 5 Replace PCCB copyir.com
When PC-410 is installed: 1 Check the connector between M131-PCCB CN5 for proper connection and correct as necessary copyir.com 2 Check the connector of M131 for proper drive coupling and correct as necessary copyir.com 3 M131 operation check PCCB CN5-5 (CW/CCW) PC-410 5-J 4 Replace M131 copyir.com 5 Replace PCCB copyir.com
C0107 Tray 3/LCT vertical transport motor turning at abnormal timing
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary copyir.com • The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary copyir.com When PC-110 or PC-210 is installed: 1 Check the connector between M112-PCCB CN5 for proper connection and correct as necessary copyir.com 2 Check the connector of M112 for proper drive coupling and correct as necessary copyir.com 3 M112 operation check PCCB CN5-13 (CW/CCW) PC-110/PC-210 3 to 4-C copyir.com 4 Replace M112 copyir.com 5 Replace PCCB copyir.com
When PC-410 is installed: 1 Check the connector between M132-PCCB CN5 for proper connection and correct as necessary copyir.com 2 Check the connector of M132 for proper drive coupling and correct as necessary copyir.com 3 M132 operation check PCCB CN5-13 (CW/CCW) PC-410 4-J copyir.com 4 Replace M132 copyir.com 5 Replace PCCB copyir.com
C0108 Tray 4 paper feed motor turning at abnormal timing
<When PC-210 is installed> • The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary copyir.com • The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary copyir.com 1 Check the connector between M121-PCCB CN9 for proper connection and correct as necessary copyir.com 2 Check the connector of M121 for proper drive coupling and correct as necessary copyir.com 3 M121 operation check PCCB CN9-5 (CW/CCW) PC-210 6-K copyir.com 4 Replace M121 copyir.com 5 Replace PCCB
C0109 Tray 4 vertical transport motor turning at abnormal timing
<When PC-210 is installed> • The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary copyir.com • The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary copyir.com 1 Check the connector between M122-PCCB CN9 for proper connection and correct as necessary copyir.com 2 Check the connector of M122 for proper drive coupling and correct as necessary copyir.com 3 M122 operation check PCCB CN9-13 (CW/CCW) PC-210 6-K copyir.com 4 Replace M122 copyir.com 5 Replace PCCB copyir.com
C0202 Tray 1 feeder up/down abnormality
The tray 1 upper limit sensor (PS22) is not blocked even after the lapse of a given period of time after the lifting motion has been started copyir.com 1 Check the connector between M12-PRCB CN25 for proper connection and correct as necessary copyir.com 2 Check the connector of M12 for proper drive coupling and correct as necessary copyir.com 3 Check the connector between PS25-relay CN30- PRCB CN26 for proper connection and correct as necessary copyir.com 4 PS25 I/O check, sensor check PRCB CN26-3 (ON) copyir.com 5 M12 operation check PRCB CN25-5 (REM) copyir.com 6 Replace M12 copyir.com 7 PRCB ICP5 conduction check copyir.com 8 Replace PRCB copyir.com
C0204 Tray 2 feeder up/down abnormality
The tray 2 upper limit sensor (PS22) is not blocked even after the lapse of a given period of time after the lifting motion has been started copyir.com 1 Check the connector between M13-PRCB CN20 for proper connection and correct as necessary copyir.com 2 Check the connector of M13 for proper drive coupling and correct as necessary copyir.com 3 Check the connector between PS22-relay CN40- PRCB CN19 for proper connection and correct as necessary copyir.com 4 PS22 I/O check, sensor check PRCB CN19-9 (ON) copyir.com 5 M13 operation check PRCB CN20-5 (REM) copyir.com 6 Replace M13 copyir.com 7 PRCB ICP4 conduction check copyir.com 8 Replace PRCB copyir.com
C0206 Tray 3 lift-up failure
The tray 3 upper limit sensor (PS116) is not blocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began copyir.com 1 Check the connector between M113-PCCB CN6 for proper connection and correct as necessary copyir.com 2 Check the connector of M113 for proper drive coupling and correct as necessary copyir.com 3 Check the connector between PS116-relay CN24- PCCB CN4 for proper connection and correct as necessary copyir.com 4 PS116 I/O check, sensor check PCCB CN4-3 (ON) copyir.com 5 M113 operation check PCCB CN6-8 to 9 copyir.com 6 Replace M113 copyir.com 7 Replace PCCB copyir.com 8 Replace MFPB copyir.com
C0208 Tray 4 lift-up failure
The tray 4 upper limit sensor (PS126) is not blocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began copyir.com 1 Check the connector between M123-PCCB CN8 for proper connection and correct as necessary copyir.com 2 Check the connector of M123 for proper drive coupling and correct as necessary copyir.com 3 Check the connector between PS126-relay CN47- PCCB CN7 for proper connection and correct as necessary copyir.com 4 PS126 I/O check, sensor check PCCB CN7-3 copyir.com 5 M123 operation check PCCB CN8-8 to 9 copyir.com 6 Replace M123 copyir.com 7 Replace PCCB copyir.com 8 Replace MFPB copyir.com
C0210 LCT lift failure
• The main tray upper limit sensor (PS136) is not blocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began copyir.com • The shifter stop / lower limit position sensor (PS138) is not unblocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began copyir.com • The main tray upper limit sensor (PS136) is not blocked even after the set period of time has elapsed after the paper lift-up operating copyir.com • The main tray upper limit sensor (PS136) is not unblocked even after the set period of time has elapsed after the paper lift-down operation began copyir.com • The shifter stop / lower limit position sensor (PS138) is not blocked even after the set period of time has elapsed after the paper lift-down operation began copyir.com 1 Check the connector between M134-PCCB CN10 for proper connection and correct as necessary copyir.com 2 Check the connector of M134 for proper drive coupling and correct as necessary copyir.com 3 Check the connector between PS136-relay CN1- PCCB CN4 for proper connection and correct as necessary copyir.com 4 Check the connector between PS138-relay CN16- PCCB CN14 for proper connection and correct as necessary copyir.com 5 PS136 I/O check, sensor check PCCB CN4-3 (ON) PC-410 8-J copyir.com 6 PS138 I/O check, sensor check PCCB CN14-6 (ON) PC-410 4-J copyir.com 7 M134 operation check PCCB CN10-1 to 2 PC-410 6-J copyir.com 8 Replace M134 copyir.com 9 PCCB IC2 conduction check copyir.com 10 Replace PCCB copyir.com
C0211 Manual feed up/down abnormality
• Paper does not unblock the bypass lift-up position sensor (PS26) even after the transport motor (M1) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position copyir.com • The bypass lift-up position sensor (PS26) is not blocked even after the transport motor (M1) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position copyir.com 1 Check the connector between M1-PRCB CN31 for proper connection and correct as necessary copyir.com 2 Check the connector of M1 for proper drive coupling and correct as necessary copyir.com 3 Check the connector between PS26-relay CN19- PRCB CN27 for proper connection and correct as necessary copyir.com 4 Check the connector between SD1-relay CN21-relay CN19-PRCB CN27 for proper connection and correct as necessary copyir.com 5 PS26 I/O check, sensor check PRCB CN27-13 (ON) 4-C copyir.com 6 SD1 operation check PRCB CN27-10 (ON) 4-C 7 copyir.com M1 operation check PRCB CN31-2 (REM) PRCB CN31-5 (LOCK) copyir.com 8 Replace M1 copyir.com 9 PRCB ICP5 conduction check copyir.com 10 Replace PRCB copyir.com
C0214 LCT shift failure
• The shifter stop / lower limit position sensor (PS138) is not blocked even after the set period of time has elapsed after the shift operation began (shift to the right) copyir.com • The shifter home sensor (PS139) is not unblocked even after the set period of time has elapsed after the shift operation began (shift to the right) copyir.com • The shifter stop / lower limit position sensor (PS138) is not unblocked even after the set period of time has elapsed after the return operation began (shift to the left) copyir.com • The shifter home sensor (PS139) is not blocked even after the set period of time has elapsed after the return operation began (shift to the left) copyir.com 1 Check the connector between M133-PCCB CN10 for proper connection and correct as necessary copyir.com 2 Check the connector of M133 for proper drive coupling and correct as necessary copyir.com 3 Check the connector between PS138-relay CN16- PCCB CN14 for proper connection and correct as necessary copyir.com 4 Check the connector between PS139-relay CN16- PCCB CN14for proper connection and correct as necessary copyir.com 5 PS138 I/O check, sensor check PCCB CN14-6 (ON) PC-410 4-J copyir.com 6 PS139 I/O check, sensor check PCCB CN14-3 (ON) PC-410 4-J copyir.com 7 M133 operation check PCCB CN10-3 to 4 PC-410 6-J copyir.com 8 Replace M133 copyir.com 9 PCCB IC2 conduction check copyir.com 10 Replace PCCB copyir.com
C1004 FNS communication error
<When FS-533 or FS-534 is installed> When the FS control board (FSCB) is receiving data, a communication error is detected copyir.com
<When JS-506 is installed> When the JS control board (JSCB) is receiving data, a communication error is detectedce M121 copyir.com 1 Turn OFF the main power switch, disconnect and then connect the power cord copyir.com Wait for 10 sec copyir.com or more after connect the power cord, and turn ON the main power switch copyir.com 2 Rewrite the firmware copyir.com 3 Replace FSCB (FS-533/FS-534) When JS-506 is installed Step Action Control signal Location of electrical components 1 Turn OFF the main power switch, disconnect and then connect the power cord copyir.com Wait for 10 sec copyir.com or more after connect the power cord, and turn ON the main power switch copyir.com 2 Rewrite the firmware copyir.com 3 Replace JSCB copyir.com
C1081 SD communication error
<When FS-534+SD-511 is installed> When a communication error is detected between the FS control board (FSCB) and the SD control board (SDDB) copyir.com 1 Turn OFF the main power switch, disconnect and then connect the power cord copyir.com Wait for 10 sec copyir.com or more after connect the power cord, and turn ON the main power switch copyir.com 2 Rewrite the firmware copyir.com 3 Replace SDDB copyir.com 4 Replace FSCB copyir.com
C1102 Main tray up/down motor’s drive malfunction
<When FS-533 is installed> • While the exit tray is being lifted, the stapler movement motor (M107) is not unblocked after the set period of time has elapsed after the tray lift up motor (M109) is turned ON copyir.com • While the exit tray is being lowered, the stapler movement motor (M107) is not blocked after the set period of time has elapsed after the tray lift up motor (M109) is turned ON
<When FS-534 is installed> • While the exit tray is being lifted, the main tray upper position sensor (PS26/PS27) is not blocked and the main tray upper position detect switch (SW2) is not turned ON, even after the main tray up/down motor (M11) turns by the set number of times copyir.com • While the exit tray is being lowered, the main tray full detection sensor (PS29) is not blocked after the set period of time has elapsed after the main tray up/down motor (M11) is turned ON copyir.comc When FS-533 is installed: 1 Check the connector between M109-FSCB CN108 for proper connection and correct as necessary copyir.com 2 Check the connector of M109 for proper drive coupling and correct as necessary copyir.com 3 Check the connector between PS107-FSCB CN110 for proper connection and correct as necessary copyir.com 4 PS107 I/O check, sensor check FSCB CN110 FS-533 7-D to E 5 M109 operation check FSCB CN108 FS-533 10-E copyir.com 6 Replace M109 copyir.com 7 FSCB CP109 conduction check copyir.com 8 Replace FSCB copyir.com
When FS-534 is installed: 1 Check the motor and sensor connectors for proper connection, and correct as necessary copyir.com 2 Check the connector of M11 for proper drive coupling, and correct as necessary copyir.com 3 PS26 I/O check, sensor check FSCB J14<A>-5 (ON) FS-534 2-C copyir.com 4 PS27 I/O check, sensor check FSCB J14<B>-8 (ON) FS-534 3-C copyir.com 5 PS29 I/O check, sensor check FSCB J14<A>-8 (ON) FS-534 4-C copyir.com 6 SW2 operation check copyir.com 7 M11 operation check FSCB J9<A>-9 to 10 FS-534 10-C to D copyir.com 8 Replace M11 copyir.com 9 Replace FSCB copyir.com
C1103 Alignment plate motor/Fr’s malfunction
<When FS-533 is installed> • The alignment plate home sensor/F (PS108) is not unblocked after the set period of time has elapsed after the plate drive starts from the home position copyir.com • The alignment plate home sensor/F (PS108) is not blocked after the set period of time has elapsed after the alignment motor/F (M105) is turned ON to return the plate to the home position copyir.com
<When FS-534 is installed> • The alignment plate/F home sensor (PS12) is not unblocked after the set period of time has elapsed after the plate drive starts from the home position copyir.com • The alignment plate/F home sensor (PS12) is not blocked after the set period of time has elapsed after the alignment motor/front (M7) is turned ON to return the plate to the home position copyir.com • The alignment plate/F does not reach the specified position within the set period of time When FS-533 is installed: 1 Check the connector between M105-FSCB CN102 for proper connection and correct as necessary copyir.com 2 Check the connector of M105 for proper drive coupling and correct as necessary copyir.com 3 Check the connector between PS108-FSCB CN102 for proper connection and correct as necessary copyir.com 4 PS108 I/O check, sensor check FSCB CN102 FS-533 7-J copyir.com 5 M105 operation check FSCB CN102 FS-533 7-J copyir.com 6 Replace M105 copyir.com 7 FSCB CP105 conduction check copyir.com 8 Replace FSCB copyir.com
When FS-534 is installed: 1 Check the connector between M7-FSCB J4 for proper connection and correct as necessary copyir.com 2 Check the connector of M7 for proper drive coupling, and correct as necessary copyir.com 3 Check the connector between PS12-FSCB J4 for proper connection and correct as necessary copyir.com 4 PS12 I/O check, sensor check FSCB J4<B>-4 (ON) FS-534 13-C copyir.com 5 M7 operation check FSCB J4<A>-5 to 8 FS-534 11-C to D copyir.com 6 Replace M7 copyir.com 7 Replace FSCB copyir.com
C1105 Bundle eject motor’s drive malfunction
<When FS-534 is installed> • The gripper home position sensor (PS18) does not block even after the set period of time has elapsed after the gripper position detection sensor (PS19) unblocked copyir.com • The gripper position detection sensor (PS19) does not block even after the set period of time has elapsed after it unblock • The gripper position detection sensor (PS19) does not block even after the set period of time has elapsed after the gripper home position sensor (PS18) unblocked copyir.com • The gripper home position sensor (PS18) does not block even after the set period of time has elapsed after the bundle eject motor (M10) unblocked copyir.com • The gripper home position sensor (PS18) and the gripper position detection sensor (PS19) are blocked at the same time copyir.com 1 Check the motor and sensor connectors for proper connection, and correct as necessary copyir.com 2 Check the connector of M10 for proper drive coupling, and correct as necessary copyir.com 3 PS18 I/O check, sensor check FSCB J13-13 (ON) FS-534 7-C copyir.com 4 PS19 I/O check, sensor check FSCB J12-3 (ON) FS-534 7-C copyir.com 5 M10 operation check FSCB J13-1 to 2 FS-534 8-C to D copyir.com 6 Replace M10 copyir.com 7 Replace FSCB copyir.com
C1106 Stapler movement motor’s malfunction
<When FS-533 is installed> • The stapler home sensor (PS110) is not unblocked after the laps of given time after it started operating from the home position copyir.com • The stapler home sensor (PS110) is not unblocked after the laps of give time after the stapler movement motor (M107) turned ON when it returned to the home position copyir.com
<When FS-534 is installed> • The stapler home position sensor (Rear) (PS23) is not blocked or unblocked even after the set period of time has elapsed after the side stapler movement motor (M13) turned ON copyir.com • The stapler does not reach the specified position within the set period of time copyir.com J When FS-533 is installed: 1 Check the connector between M107-STREYB CN123 for proper connection, and correct as necessary copyir.com 2 Check the connector of M107 for proper drive coupling, and correct as necessary copyir.com 3 Check the connector between PS110-FSCB CN110 for proper connection, and correct as necessary copyir.com 4 PS110 I/O check, sensor check FSCB CN110 FS-533 8-D to E copyir.com 5 M107 operation check STREYB CN123-5 to 8 FS-533 5-L copyir.com 6 Replace M107 copyir.com 7 Replace STREYB copyir.com 8 FSCB CP107 conduction check copyir.com 9 Replace FSCB copyir.com
When FS-534 is installed: 1 Check the connector between M13-relay CN3-FSCB J11 for proper connection, and correct as necessary copyir.com 2 Check the connector of M13 for proper drive coupling, and correct as necessary copyir.com 3 Check the connector between PS23-relay CN3-FSCB J11 for proper connection, and correct as necessary copyir.com 4 PS23 I/O check, sensor check FSCB J11<B>-3 (ON) FS-534 4-C copyir.com 5 M13 operation check FSCB J11<A>-1 to 4 FS-534 4-C to D copyir.com 6 Replace M13 copyir.com 7 Replace FSCB copyir.com
C1109 Stapler motor’s drive malfunction
<When FS-533 is installed> The stapler home sensor (PS110) is not blocked even after the set period of time has elapsed after the stapler motor turned ON copyir.com
<When FS-534 is installed> • The stapler home position sensor (Rear) (PS23) is not blocked or unblocked even after the set period of time has elapsed after the stapler motor (M14) turned ON copyir.com • The stapler position sensor (Center) (PS24) is blocked, when the stapler motor (M14) is running copyir.com When FS-533 is installed: 1 Check the connector between the stapler unit- STREYB CN122 and CN123 for proper connection and correct as necessary copyir.com 2 Check the connector of the stapler unit for proper drive coupling and correct as necessary copyir.com 3 Check the connector between PS110-FSCB CN110 for proper connection and correct as necessary copyir.com 4 PS110 I/O check, sensor check FSCB CN110 FS-533 8-D to E copyir.com 5 Replace the stapler unit copyir.com 6 Replace STREYB copyir.com 7 Replace FSCB copyir.com
When FS-534 is installed: 1 Check the connector between the stapler unit-relay CN4-FSCB J11 for proper connection and correct as necessary copyir.com 2 Check the connector of the stapler unit for proper drive coupling, and correct as necessary copyir.com 3 Check the connector between PS23-relay CN3-FSCB J11 for proper connection and correct as necessary copyir.com 4 Check the connector between PS24-relay CN3-FSCB J11 for proper connection and correct as necessary copyir.com 5 PS23 I/O check, sensor check FSCB J11<B>-3 (ON) FS-534 4-C copyir.com 6 PS24 I/O check, sensor check FSCB J11<B>-6 (ON) FS-534 4 to 5-C copyir.com 7 Replace the stapler unit copyir.com 8 Replace FSCB copyir.com
C1112 Stapler motor’s malfunction
<When FS-534+SD-511 is installed> • The stapler home sensor is not turned ON even after the set period of time has elapsed while the stapler motor is energized copyir.com • The stapler home sensor is not turned OFF even after the set period of time has elapsed after the stapler home sensor is turned ON copyir.com 1 Check the connector between the staple unit-SDDB J4 for proper connection and correct as necessary copyir.com 2 Check the connector of the staple unit for proper drive coupling and correct as necessary copyir.com 3 Replace the staple unit copyir.com 4 Replace SDDB copyir.com 5 Replace FSCB copyir.com
C1113 Center-staple lead edge stopper motor malfunction
<When FS-534+SD-511 is installed> The stopper home sensor (PS6) is not blocked or unblocked even after the set period of time has elapsed after the stopper drive motor (M4) is turned ON copyir.com 1 Check the connector between M4-SDDB J10 for proper connection and correct as necessary copyir.com 2 Check the connector of M4 for proper drive coupling, and correct as necessary copyir.com 3 Check the connector between PS6-SDDB J10 for proper connection, and correct as necessary copyir.com 4 PS6 I/O check, sensor check SDDB J10-5 (ON) SD-511 2-G copyir.com 5 M4 operation check SDDB J10-6 to 9 SD-511 1 to 2-F to G copyir.com 6 Replace M4 copyir.com 7 Replace SDDB copyir.com 8 Replace FSCB copyir.com
C1114 Center-staple front adjust drive motor malfunction
<When FS-534+SD-511 is installed> The alignment home sensor (PS4) is not blocked or unblocked even after the set period of time has elapsed after the alignment motor (M3) is turned ON copyir.com 1 Check the connector between M3-relay CN10-SDDB J7 for proper connection and correct as necessary copyir.com 2 Check the connector of M3 for proper drive coupling, and correct as necessary copyir.com 3 Check the connector between PS4-relay CN10-SDDB J7 for proper connection, and correct as necessary copyir.com 4 PS4 I/O check, sensor check SDDB J7-6 (ON) SD-511 6-F copyir.com 5 M3 operation check SDDB J7 7 to 10 SD-511 5-F to G copyir.com 6 Replace M3 copyir.com 7 Replace SDDB copyir.com 8 Replace FSCB copyir.com
C1115 Center-staple knife drive motor malfunction
<When FS-534+SD-511 is installed> The center fold knife home sensor (PS8) is not blocked or unblocked even after the set period of time has elapsed after the center fold knife motor (M9) is turned ON copyir.com 1 Check the connector between M9-SDDB J11 for proper connection and correct as necessary copyir.com 2 Check the connector of M9 for proper drive coupling, and correct as necessary copyir.com 3 Check the connector between PS8-relay CN10-SDDB J7 for proper connection, and correct as necessary copyir.com 4 PS8 I/O check, sensor check SDDB J7-3 (ON) SD-511 6-G copyir.com 5 M9 operation check SDDB J11 11 to 20 SD-511 1 to 2-B copyir.com 6 Replace M9 copyir.com 7 Replace SDDB copyir.com 8 Replace FSCB copyir.com
C1132 Punch drive motor’s malfunction
<When FS-533+PK-519 is installed> • The puncher drive cam sensor (PS203) or puncher home sensor (PS204) is not blocked or unblocked even after the set period of time has elapsed while the punch motor (M201) is energized copyir.com • The punch motor sensor (PS202) does not turn ON after the punch motor (M201) stopped copyir.com • The holes with other marketing area is set in [Service Mode] – [Finisher] – [Punch Option Setting]
<When FS-534+PK-520 is installed> The punch home sensor (PS1) is not blocked or unblocked even after the set period of time has elapsed while the punch drive motor (M1) is energized copyir.com When FS-533+PK-519 is installed: 1 Check the number of the holes in [Service Mode] – [Finisher] – [Punch Option Setting] copyir.com 2 Check the connector between M201-PKCB CN203 for proper connection, and correct as necessary copyir.com 3 Check the connector of M201 for proper drive coupling, and correct as necessary copyir.com 4 Check the connector between PS202-PKCB CN204 for proper connection, and correct as necessary copyir.com 5 Check the connector between PS203-PKCB CN204 copyir.com for proper connection, and correct as necessary copyir.com 6 Check the connector between PS204-PKCB CN204 for proper connection, and correct as necessary copyir.com 7 PS202 I/O check, sensor check PKCB CN204 FS-533 (PK-519) 5-C copyir.com 8 PS203 I/O check, sensor check PKCB CN204 FS-533 (PK-519) 6-C copyir.com 9 PS204 I/O check, sensor check PKCB CN204 FS-533 (PK-519) 6-C copyir.com 10 M201 operation check PKCB CN203-1 to 2 FS-533 (PK-519) 4-C copyir.com 11 Replace M201 copyir.com 12 PKCB F201 conduction check copyir.com 13 Replace PKCB copyir.com 14 Replace FSCB copyir.com
When FS-534+PK-520 is installed: 1 Check the connector between M1-relay CN351-FSCB J7 for proper connection, and correct as necessary copyir.com 2 Check the connector of M1 for proper drive coupling, and correct as necessary copyir.com 3 Check the connector between PS1-FSCB J7 for proper connection, and correct as necessary copyir.com 4 PS1 I/O check, sensor check FSCB J7-5 (ON) FS-534 (PK-520) 7-K copyir.com 5 M1 operation check FSCB J7 7 to 8 FS-534 (PK-520) 7-K 6 Replace M1 copyir.com 7 Replace FSCB copyir.com
C1140 Alignment plate motor/Rr’s malfunction
<When FS-533 is installed> • The alignment plate home sensor/R (PS109) is not unblocked after the set period of time has elapsed after the plate drive starts from the home position copyir.com • The alignment plate home sensor/R (PS109) is not blocked after the set period of time has elapsed when the plate returns to the home position copyir.com
<When FS-534 is installed> The alignment plate/R home sensor (PS13) is not blocked or unblocked even after the set period of time has elapsed while the alignment motor/Rr (M8) is energized copyir.com When FS-533 is installed: 1 Check the connector between M106-FSCB CN102 for proper connection and correct as necessary copyir.com 2 Check the connector of M106 for proper drive coupling and correct as necessary copyir.com 3 Check the connector between PS109-relay CN106- FSCB CN102 for proper connection and correct as necessary copyir.com 4 PS109 I/O check, sensor check FSCB CN102 FS-533 7-J 5 M106 operation check FSCB CN102 FS-533 8-J 6 Replace M106 copyir.com 7 FSCB CP105 conduction check copyir.com 8 Replace FSCB copyir.com
When FS-534 is installed: 1 Check the connector between M8-FSCB J12 for proper connection, and correct as necessary copyir.com 2 Check the connector of M8 for proper drive coupling, and correct as necessary copyir.com 3 Check the connector between PS13-FSCB J9 for proper connection, and correct as necessary copyir.com 4 PS13 I/O check, sensor check FSCB J9<B>-9 (ON) FS-534 9-C copyir.com 5 M8 operation check FSCB J12-13 to 16 FS-534 5~6-C to D 6 Replace M8 copyir.com 7 Replace FSCB copyir.com
C1141 Paddle motor’s drive malfunction
<When FS-534 is installed> The upper paddle homeposition detection sensor (PS14) is not blocked or unblocked even after the set period of time has elapsed while the FNS paddle motor (M5) is turning copyir.com 1 Check the connector between M5-FSCB J4 for proper connection, and correct as necessary copyir.com 2 Check the connector of M5 for proper drive coupling, and correct as necessary copyir.com 3 Check the connector between PS14-FSCB J4 for proper connection, and correct as necessary copyir.com 4 PS14 I/O check, sensor check FSCB J4<B>-7 (ON) FS-534 13-C copyir.com 5 M5 operation check FSCB J4<A>-5 to 8 FS-534 12-C to D copyir.com 6 Replace M5 copyir.com 7 Replace FSCB copyir.com
C1144 Pre-eject drive motor’s malfunction
<When FS-534 is installed> • The pre-eject home sensor (PS21) is not blocked or unblocked even after the set period of time has elapsed after the pre-eject drive motor (M9) is turned ON copyir.com • The pre-eject away sensor (PS22) is not blocked or unblocked even after the set period of time has elapsed after the pre-eject drive motor (M9) is turned ON copyir.comk 1 Check the connector between M9-relay CN7<A>- FSCB J13 for proper connection, and correct as necessary copyir.com 2 Check the connector of M9 for proper drive coupling, and correct as necessary copyir.com 3 Check the connector between PS21-relay CN8-relay CN7<B>-FSCB J12 for proper connection, and correct as necessary copyir.com 4 Check the connector between PS22-relay CN8-relay CN7<B>-FSCB J12 for proper connection, and correct as necessary copyir.com 5 PS21 I/O check, sensor check FSCB J12-6 (ON) FS-534 6-C copyir.com 6 PS22 I/O check, sensor check FSCB J12-9 (ON) FS-534 6-C copyir.com 7 M9 operation check FSCB J13-3 to 4 FS-534 8-C to D copyir.com 8 Replace M9 copyir.com 9 Replace FSCB copyir.com
C1145 Trailing edge stopper motor’s malfunction
<When FS-534 is installed> The trailing edge stopper home position detection sensor (PS20) is not blocked or unblocked even after the set period of time has elapsed after the trailing edge stopper motor (M6) is turned ON copyir.com 1 Check the connector between M6-FSCB J5 for proper connection, and correct as necessary copyir.com 2 Check the connector of M6 for proper drive coupling, and correct as necessary copyir.com 3 Check the connector between PS20-relay CN22-FSCB J5 for proper connection, and correct as necessary copyir.com 4 PS20 I/O check, sensor check FSCB J5-9 (ON) FS-534 9-K copyir.com 5 M6 operation check FSCB J5-13 to 16 FS-534 9-K copyir.com 6 Replace M6 copyir.com 7 Replace FSCB copyir.com
C1156 Center-staple paddle roller motor malfunction (trailing edge)
<When FS-534+SD-511 is installed> The paddle home sensor (PS5) is not blocked or unblocked even after the set period of time has elapsed while the SD paddle motor (M7) is energized copyir.com 1 Check the connector between M7-SDDB J8 for proper connection and correct as necessary copyir.com 2 Check the connector of M7 for proper drive coupling, and correct as necessary copyir.com 3 Check the connector between PS5-SDDB J8 for proper connection and correct as necessary copyir.com – – 5 PS5 I/O check, sensor check SDDB J8-3 (ON) SD-511 3 to 4-G copyir.com 7 M7 operation check SDDB J8 4 to 7 SD-511 3-F to G copyir.com 8 Replace M7 copyir.com 9 Replace SDDB copyir.com 10 Replace FSCB copyir.com
C1182 Shift motor drive malfunction
<When JS-506 is installed> • The tray shift home sensor (PS1) is not unblocked after the set period of time has elapsed after the tray shift motor (M1) is turned ON (start of moving to the home position copyir.com) • The tray shift home sensor (PS1) is not blocked after the set period of time has elapsed after the tray shift motor (M1) is turned ON (start of moving to the shift position copyir.com) 1 Check the connector between M1-JSCB CN208 for proper connection and correct as necessary copyir.com 2 Check the connector of M1 for proper drive coupling, and correct as necessary copyir.com – – 3 Check the connector between PS1-JSCB CN208 for proper connection and correct as necessary copyir.com 4 PS1 I/O check, sensor check JSCB CN208-5 (ON) JS-506 5-C copyir.com 5 M1 operation check JSCB CN208 1 (DRV) JS-506 4 to 5-C copyir.com 6 Replace M1 copyir.com 7 JSCB ICP3 conduction check copyir.com 8 Replace JSCB copyir.com
C1184 Paper discharge control motor’s malfunction
<When FS-534 is installed> The paper delivery control sensor (PS28) is not blocked or unblocked even after the set period of time has elapsed while the paper receiving control motor (M12) is energized copyir.com 1 Check the connector between M12-relay CN1-FRCB J14 for proper connection, and correct as necessary copyir.com 2 Check the connector of M12 for proper drive coupling, and correct as necessary copyir.com 3 Check the connector between PS28-relay CN1-FRCB J14 for proper connection, and correct as necessary copyir.com 4 PS28 I/O check, sensor check FSCB J14<B>-3 (ON) FS-534 2~3-C copyir.com 5 M12 operation check FSCB J14<A>-9 to 12 FS-534 2-C to D copyir.com 6 Replace M12 copyir.com 7 Replace FSCB copyir.com
C1195 Paper discharge control motor’s malfunction
<When FS-534+SD-511 is installed> The curl cover detection sensor (PS2) is not blocked or unblocked even after the set period of time has elapsed after the paper discharge control motor (M2) is turned ON copyir.com 1 Check the connector between M2-relay CN3-relay CN2-SDDB J5 for proper connection, and correct as necessary copyir.com 2 Check the connector of M2 for proper drive coupling, and correct as necessary copyir.com 3 Check the connector between PS2-relay CN3-relay CN2-SDDB J5 for proper connection, and correct as necessary copyir.com 4 PS2 I/O check, sensor check SDDB J5 3 (ON) SD-511 3-B 5 M2 operation check SDDB J5 4 to 7 SD-511 3-B copyir.com 6 Replace M2 copyir.com 7 Replace SDDB copyir.com 8 Replace FSCB copyir.com
C1196 Center fold roller motor’s malfunction
<When FS-534+SD-511 is installed> The guide home sensor (PS7) is not blocked or unblocked even after the set period of time has elapsed after the center fold roller motor (M8) is turned ON copyir.com 1 Check the connector between M8-SDDB J8 for proper connection, and correct as necessary copyir.com 2 Check the connector of M8 for proper drive coupling, and correct as necessary copyir.com 3 Check the connector between PS7-SDDB J9 for proper connection, and correct as necessary copyir.com 4 PS7 I/O check, sensor check SDDB J9-6 (ON) SD-511 4-G copyir.com 5 M8 operation check SDDB J10 6 to 9 SD-511 1 to 2-F to G copyir.com 6 Replace M8 copyir.com 7 Replace SDDB copyir.com 8 Replace FSCB copyir.com
C1197 Tri-folding guide motor’s malfunction
<When FS-534+SD-511 is installed> The tri-folding gate home sensor (PS11) is not blocked or unblocked even after the set period of time has elapsed while the tri-folding guide motor (M6) is energized copyir.com 1 Check the connector between M6-SDDB J9 for proper connection, and correct as necessary copyir.com – – 2 Check the connector of M6 for proper drive coupling, and correct as necessary copyir.com 3 Check the connector between PS11-SDDB J8 for proper connection, and correct as necessary copyir.com 4 PS11 I/O check, sensor check SDDB J8-10 (ON) SD-511 3-G copyir.com 5 M6 operation check SDDB J9 7 to 10 SD-511 4-F to G copyir.com 6 Replace M6 copyir.com 7 Replace SDDB copyir.com 8 Replace FSCB copyir.com
C11A1 Exit roller pressure/ retraction malfunction
<When FS-533 is installed> The pick up roller position sensor (PS105) is turned neither ON nor OFF even after the set period of time has elapsed after the exit roller lift up motor (M104) is turned ON copyir.com 1 Check the connector between M104-FSCB CN109 for proper connection and correct as necessary copyir.com 2 Check the connector of M104 for proper drive coupling, and correct as necessary copyir.com 3 Check the connector between PS105-FSCB CN110 for proper connection and correct as necessary copyir.com 4 PS105 I/O check, sensor check FSCB CN110 FS-533 7-D to E copyir.com 5 M104 operation check FSCB CN109 FS-533 9-D to E copyir.com 6 Replace M104 copyir.com 7 FSCB CP104 conduction check copyir.com 8 Replace FSCB copyir.com
C11A2 Accommodation roller pressure/ retraction malfunction
<When FS-534 is installed> The receiving roller retraction sensor (PS11) is not blocked or unblocked even after the set period of time has elapsed after the receiving roller retraction motor (M4) is turned ON copyir.com 1 Check the connector between M4-FSCB J4 for proper connection and correct as necessary copyir.com 2 Check the connector of M4 for proper drive coupling, and correct as necessary copyir.com 3 Check the connector between PS11-FSCB J4 for proper connection, and correct as necessary copyir.com 4 PS11 I/O check, sensor check FSCB J4<B>-16 (ON) FS-534 13-C copyir.com 5 M4 operation check FSCB J4<A>-1 to 4 FS-534 11-C to D copyir.com 6 Replace M4 copyir.com 7 Replace FSCB copyir.com
C11E1 Paper exit switching drive malfunction
<When FS-534 is installed> The exchange folded knife home position sensor (PS30) is not blocked or unblocked even after the set period of time has elapsed after the FNS entry transport motor (M2) is turned ON copyir.com 1 Check the connector between M2-FSCB J9 for proper connection and correct as necessary copyir.com 2 Check the connector of M2 for proper drive coupling, and correct as necessary copyir.com 3 Check the connector between PS30-FSCB J4 for proper connection, and correct as necessary copyir.com 4 PS30 I/O check, sensor check FSCB J4<A>-15 (ON) FS-534 12-C copyir.com 5 M2 operation check FSCB J9<A>-1 to 4 FS-534 10 to 11-B to C copyir.com 6 Replace M2 copyir.com 7 Replace FSCB copyir.com
C1402 FS nonvolatile memory error
<When FS-533 is installed> When the main power switch is turned ON, malfunctioning of the nonvolatile memory on the FS control board (FSCB) is detected copyir.com 1 Disconnect and then connect the power cord copyir.com Turn OFF the main power switch, wait for 10 sec copyir.com or more, and turn ON the main power switch copyir.com 2 Rewrite the firmware copyir.com 3 Replace FSCB copyir.com
C2152 Transfer belt pressure welding alienation
• The 1st transfer pressure sensor (PS39) does not detect “switch from retraction to pressure” within a given period time after 1st transfer pressure clutch (CL5) has stared engagement copyir.com • The 1st transfer pressure sensor (PS39) is unblocked after the laps of given time after the 1st transfer pressure clutch (CL5) turned OFF when the pressing operation is finished copyir.com • The 1st transfer pressure sensor (PS39) does not detect “switch from pressure to retraction” within a given period time after 1st transfer pressure clutch (CL5) has stared engagement copyir.com • The 1st transfer pressure sensor (PS39) is blocked after the lamps of given time after the 1st transfer pressure clutch (CL5) turned OFF when the release operation is finished copyir.com 1 Check the connector between M3-PRCB CN2 for proper connection and correct as necessary copyir.com 2 Check the connector of M3 for proper drive coupling and correct as necessary copyir.com 3 Check the connector between PS39-relay CN113- PRCB CN13 for proper connection and correct as necessary copyir.com 4 Check the connector between CL5-relay CN118-PRCB CN13 for proper connection and correct as necessary copyir.com 5 PS39 I/O check, sensor check PRCB CN13-7 (ON) 24-C copyir.com 6 CL5 operation check PRCB CN13-14 (ON) 23 to 24-C copyir.com 7 M3 operation check PRCB CN2-9 (REM) PRCB CN2-12 (LOCK) 27-I to J copyir.com 8 Replace M3 copyir.com 9 PRCB ICP3 conduction check copyir.com 10 Replace PRCB copyir.com
C2253 PC motor’s failure to turn
The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning copyir.com 1 Check the connector between M2-PRCB CN31 for proper connection and correct as necessary copyir.com 2 Check the M2 connector for proper drive coupling and correct as necessary copyir.com 3 M2 operation check PRCB CN31-9 (REM) PRCB CN31-12 (LOCK) 4 Replace M2 copyir.com 5 Replace PRCB copyir.com
C2254 PC motor’s turning at abnormal timing
The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary copyir.com 1 Check the connector between M2-PRCB CN31 for proper connection and correct as necessary copyir.com 2 Check the M2 connector for proper drive coupling and correct as necessary copyir.com 3 M2 operation check PRCB CN31-9 (REM) PRCB CN31-12 (LOCK) 4 Replace M2 copyir.com 5 Replace PRCB copyir.com
C2255 Developing motor’s failure to turn
The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning copyir.com 1 Check the connector between M21-PRCB CN32 for proper connection and correct as necessary copyir.com 2 Check the M21 connector for proper drive coupling and correct as necessary copyir.com 3 M21 operation check PRCB CN32-2 (REM) PRCB CN32-5 (LOCK) copyir.com bizhub C224 25-I to J 4 Replace M21 copyir.com 5 Replace PRCB copyir.com
C2256 Developing motor’s turning at abnormal timing
The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary copyir.com 1 Check the connector between M21-PRCB CN32 for proper connection and correct as necessary copyir.com 2 Check the M21 connector for proper drive coupling and correct as necessary copyir.com 3 M21 operation check PRCB CN32-2 (REM) PRCB CN32-5 (LOCK) copyir.com bizhub C224 25-I to J 4 Replace M21 copyir.com 5 Replace PRCB copyir.com
C2355 Transfer belt cleaner cooling fan motor’s failure to turn
The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning copyir.com 1 Check the connector between FM2-relay CN115- PRCB CN13 for proper connection and correct as necessary copyir.com 2 Check the fan for possible overload and correct as necessary copyir.com 3 FM2 operation check PRCB CN13-8 (REM) PRCB CN13-10 (LOCK) 24-C copyir.com 4 Replace FM2 copyir.com 5 PRCB ICP3 conduction check copyir.com 6 Replace PRCB copyir.com
C2411 Developing unit/C new article release
The status with the new unit is not cleared after the new developing unit is set copyir.com 1 Reinstall developing unit copyir.com 2 Check the connector between developing unit-FRB CN13, CN14, CN15, CN16 for proper connection and correct as necessary copyir.com 3 Check the connector between FRB CN1, CN3-PRCB CN7, CN9 for proper connection and correct as necessary copyir.com 4 Replace the developing unit copyir.com 5 Replace FRB copyir.com 6 Replace PRCB copyir.com
C9403 CIS LED lighting failure
<When DF-701 is installed> At the CIS gain adjustment, the machine detected that the output of the CIS LED is lower than the specified value copyir.com 1 Correct the harness connection between CIS and DSIPB if faulty copyir.com 2 Correct the harness connection between CIS and CISPU if faulty copyir.com 3 Replace CIS copyir.com 4 CISPU F1, F2 conduction check copyir.com 5 Replace CISPU copyir.com 6 Replace DSIPB copyir.com 7 Replace MFPB copyir.com
C9404 CIS LED lighting abnormally
<When DF-701 is installed> After a scan job is completed, the machine detected that the average output of the CIS LED is greater than the specified value copyir.com 1 Correct the harness connection between CIS and DSIPB if faulty copyir.com 2 Correct the harness connection between CIS and CISPU if faulty copyir.com 3 Replace CIS copyir.com 4 CISPU F1, F2 conduction check copyir.com 5 Replace CISPU copyir.com 6 Replace DSIPB copyir.com 7 Replace MFPB copyir.com
CA051 Standard controller configuration failure
The controller of the MFP board (MFPB) is faulty copyir.com
CA052 Controller hardware error
A controller hardware error is detected in the network interface copyir.com 1 Check to see if the following setting has been correctly made: [Service Mode] – [System 2] – [Image Controller Setting] copyir.com If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more copyir.com 2 Check the connectors of the MFPB for proper connection and correct as necessary copyir.com 3 Replace MFPB copyir.com
CA053 Controller start failure
A controller start failure is detected in the controller interface copyir.com 1 Check to see if the following setting has been correctly made: [Service Mode] – [System 2] – [Image Controller Setting] copyir.com If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more copyir.com 2 Check the connectors of the MFPB for proper connection and correct as necessary copyir.com 3 Replace MFPB copyir.com
CB001 copyir.com copyir.com copyir.com CB119 FAX board error
CB120 copyir.com copyir.com copyir.com CB196 Controller error
CC001 Vendor connection failure
CC151 copyir.com copyir.com copyir.com CC165 ROM contents error
CD004 copyir.com copyir.com copyir.com CD047 Hard disk error