کو نیکا مینو لتا magicolor1690mf
- Transport motor malfunction
• The motor lock signal remains HIGH for a predetermined consecutive period of time while the transport motor remains energized copyir copyir.comcom 1 Check the M1 connector for proper connection and correct as necessary copyir copyir.comcom 2 Check M1 for proper drive coupling and correct as necessary copyir copyir.comcom 3 Check the PRCB connector for proper connection and correct as necessary copyir copyir.comcom 4 M1 operation check PRCB PJ8-1 to 6 C-2 copyir copyir.comcom 5 Change M1 copyir copyir.comcom 6 Change PRCB copyir copyir.comcom 7 Change DCPU copyir copyir.comcom
001B Developing motor malfunction
• The developing motor does not rotate evenly even after the lapse of a given period of time while it is being started copyir copyir.comcom • The motor lock signal remains HIGH for a given period of consecutive time while the developing motor is being rotated copyir copyir.comcom 1 Check the developing motor connector for proper connection and correct as necessary copyir copyir.comcom 2 Check the PRCB connector for proper connection and correct as necessary copyir copyir.comcom 3 M3 operation check PRCB PJ5-1 to 4 C-12 copyir copyir.comcom 4 Change M3 copyir copyir.comcom 5 Change PRCB copyir copyir.comcom 6 Change DCPU copyir copyir.comcom
0045 Exit tray cooling fan motor malfunction 1 Check the FM4 connector for proper connection and correct as necessary copyir copyir.comcom 2 Check the fan for possible overload and correct as necessary copyir copyir.comcom 3 FM4 operation check PRCB PJ24-4 (REM) PRCB PJ24-6 (LOCK) C-13 copyir copyir.comcom 4 Change FM4 copyir copyir.comcom 5 Change MFPB copyir copyir.comcom
004A Duplex cooling fan motor malfunction
004C Ozone ventilation fan motor malfunction
• The ozone ventilation fan motor does not rotate evenly even after the lapse of a given period of time while it is being started copyir copyir.comcom • The motor lock signal remains HIGH for a given period of consecutive time while the ozone ventilation fan motor is being rotated copyir copyir.comcom 1 Check the FM2 connector for proper connection and correct as necessary copyir copyir.comcom 2 Check the fan for possible overload and correct as necessary copyir copyir.comcom 3 FM2 operation check PRCB PJ16-1 (REM) PRCB PJ16-3 (LOCK) C-4 copyir copyir.comcom 4 Change FM2 copyir copyir.comcom 5 Change PRCB copyir copyir.comcom
004E DC power supply fan motor malfunction
• The DC power supply fan motor does not rotate evenly even after the lapse of a given period of time while it is being started copyir copyir.comcom • The motor lock signal remains HIGH for a given period of consecutive time while the DC power supply fan motor is being rotated copyir copyir.comcom 1 Check the FM1 connector for proper connection and correct as necessary copyir copyir.comcom 2 Check the fan for possible overload and correct as necessary copyir copyir.comcom 3 FM1 operation check HV CN2-1 (REM) HV CN2-3 (LOCK) B-4 to 5 copyir copyir.comcom 4 Change FM1 copyir copyir.comcom 5 Change PRCB copyir copyir.comcom
0092 Transfer belt rotation failure
• The belt positioning sensor does not detect the transfer belt position detection hole a second time even after the lapse of a predetermined period of time after it has detected one while the transfer belt is rotated copyir copyir.comcom 1 Check the PRCB connector for proper connection and correct as necessary copyir copyir.comcom 2 PS6 sensor check copyir copyir.comcom 3 Change imaging cartridge copyir copyir.comcom 4 Change PRCB copyir copyir.comcom
0094 2nd image transfer pressure / retraction failure
• The 2nd image transfer retraction position sensor is not activated (retracted position) within a given period of time after the retraction sequence of the 2nd transfer roller has been started copyir copyir.comcom • The 2nd image transfer retraction position sensor is not deactivated (pressed position) within a given period of time after the pressure sequence of the 2nd transfer roller has been started copyir copyir.comcom 1 Check the M1 connector for proper connection and correct as necessary copyir copyir.comcom 2 Check the SD4 connector for proper connection and correct as necessary copyir copyir.comcom 3 Check M1 for proper drive coupling and correct as necessary copyir copyir.comcom 4 Check SD4 for proper drive coupling and correct as necessary copyir copyir.comcom 5 Check the PRCB connector for proper connection and correct as necessary copyir copyir.comcom 6 PS3 sensor check PRCB PJ12-3 (ON) C-2 copyir copyir.comcom 7 SD4 operation check PRCB PJ10-6 (REM) C-9 copyir copyir.comcom 8 M1 operation check PRCB PJ8-1 to 6 C-2 copyir copyir.comcom 9 Change M1 copyir copyir.comcom 10 Change SD4 copyir copyir.comcom 11 Change PRCB copyir copyir.comcom
0300 Polygon motor malfunction
• The polygon motor does not rotate evenly even after the lapse of a given period of time after it has been started copyir copyir.comcom • The motor lock signal remains HIGH for a given period of consecutive time while the polygon motor is being rotated copyir copyir.comcom 1 Check the cable and connector for proper connection and correct as necessary copyir copyir.comcom 2 Change PH unit copyir copyir.comcom 3 Change PRCB copyir copyir.comcom
0310 Laser malfunction
• The SOS signal is not detected within a given period of time after the output of the laser has been started copyir copyir.comcom 1 Check the cable and connector for proper connection and correct as necessary copyir copyir.comcom 2 Change PH unit copyir copyir.comcom 3 Change PRCB copyir copyir.comcom
0500 Fuser warm-up failure
• The thermistor /1 does not detect the specified temperature and the warm-up cycle is not completed even after the lapse of a given period of time after the cycle has been started copyir copyir.comcom 1 Change fuser unit copyir copyir.comcom 2 1 copyir copyir.comcom Main switch is turned ON copyir copyir.comcom 2 copyir copyir.comcom Open the top cover copyir copyir.comcom 3 copyir copyir.comcom Press the following ten keys in this order 2-6-2-3-7 copyir copyir.comcom 4 copyir copyir.comcom Main switch is turned OFF/ON copyir copyir.comcom 3 Change PRCB copyir copyir.comcom 4 Change DCPU copyir copyir.comcom
0502 Thermistor open-circuit failure
• The temperature detected by the thermistor does not reach a predetermined level even after the lapse of a given period time after the warm-up cycle has been started copyir copyir.comcom 1 Check the fuser unit for correct installation (whether it is secured in position) copyir copyir.comcom 2 Check the fuser unit, DCPU, and PRCB for proper connection and correct as necessary copyir copyir.comcom 3 Change fuser unit copyir copyir.comcom 4 Change PRCB copyir copyir.comcom 5 Change DCPU copyir copyir.comcom
0503 Thermistor resistance failure
• The difference between the temperature detected by thermistor/1 and that detected by thermistor/2 exceeds a predetermined value copyir copyir.comcom 1 Change fuser unit copyir copyir.comcom 2 1 copyir copyir.comcom Main switch is turned ON copyir copyir.comcom 2 copyir copyir.comcom Open the top cover copyir copyir.comcom 3 copyir copyir.comcom Press the following ten keys in this order 2-6-2-3-7 copyir copyir.comcom 4 copyir copyir.comcom Main switch is turned OFF/ON copyir copyir.comcom 3 Change PRCB copyir copyir.comcom 4 Change DCPU copyir copyir.comcom
0510 Abnormally low fuser temperature
• The temperature detected by the thermistor /1 remains lower than the specified value for a given period of time or longer copyir copyir.comcom 1 Check the fuser unit for correct installation (whether it is secured in position) copyir copyir.comcom 2 Check the fuser unit, DCPU, and PRCB for proper connection and correct as necessary copyir copyir.comcom 3 Change fuser unit copyir copyir.comcom 4 Change PRCB copyir copyir.comcom 5 Change DCPU copyir copyir.comcom
0520 Abnormally high fuser temperature
• The temperature detected by the thermistor /1 remains higher than the specified value for a given period of time or longer copyir copyir.comcom • The heater lamp remains ON for a given period of time or longer copyir copyir.comcom 1 Check the fuser unit for correct installation (whether it is secured in position) copyir copyir.comcom 2 Check the fuser unit, DCPU, and PRCB for proper connection and correct as necessary copyir copyir.comcom 3 Change fuser unit copyir copyir.comcom 4 Change PRCB copyir copyir.comcom 5 Change DCPU copyir copyir.comcom
0650 Scanner home sensor abnormalities 1 Check to see if the lock lever of the Scanner unit is unlocked and unlock the lock lever if it is locked copyir copyir.comcom 2 Check the M101 connector for proper connection and correct as necessary copyir copyir.comcom 3 Check M101 for proper drive coupling and correct as necessary copyir copyir.comcom 4 Check the PRCB connector for proper connection and correct as necessary copyir copyir.comcom 5 M101 operation check copyir copyir.comcom MFPB P2-1 to 4 1680MF: J-12 1690MF: J-6 copyir copyir.comcom 6 Change PRCB copyir copyir.comcom 7 Change DCPU copyir copyir.comcom
0F51 Waste toner full sensor malfunction
• It is determined that the LED and photo receiver are faulty through a check made when a new imaging cartridge is detected copyir copyir.comcom 1 Check the PRCB connector for proper connection and correct as necessary copyir copyir.comcom 2 PS7 sensor check copyir copyir.comcom 3 Change imaging cartridge copyir copyir.comcom 4 Change PRCB copyir copyir.comcom
1038 Engine connect error 1 Turn OFF and ON the power switch copyir copyir.comcom 2 Check the PRCB connector for proper connection and correct as necessary copyir copyir.comcom 3 Check the MFPB connector for proper connection and correct as necessary copyir copyir.comcom 4 Check for proper connection between PRCB and MFPB and correct as necessary copyir copyir.comcom 5 Change MFPB copyir copyir.comcom 6 Change PRCB copyir copyir.comcom
13C0 Print control board malfunction
• A communication error occurs in print control board (PRCB) copyir copyir.comcom 1 Reboot the main body copyir copyir.comcom 2 Change PRCB copyir copyir.comcom
13DD Backup data error
• The printer determines that EEPROM is yet to be mounted when the main power switch is turned ON copyir copyir.comcom 1 Check the cable and connector for proper connection and correct as necessary copyir copyir.comcom 2 Change PRCB copyir copyir.comcom 3 Change MFPB copyir copyir.comcom
13E2 Engine flash ROM write error
• Flash ROM writing is found faulty during a check copyir copyir.comcom 1 Check the cable and connector for proper connection and correct as necessary copyir copyir.comcom 2 Change PRCB copyir copyir.comcom 3 Change MFPB copyir copyir.comcom
13F0 Engine control failure
• An undefined malfunction occurs in the engine section (PRCB, etc copyir copyir.comcom) copyir copyir.comcom 1 Check the cable and connector for proper connection and correct as necessary copyir copyir.comcom 2 Change PRCB copyir copyir.comcom 3 Change MFPB copyir copyir.comcom
14A3 IR lamp malfunction 1 Check the exposure lamp for lighting condition when the power switch is turned ON and, if any faulty symptom is evident, correct the Scanner Unit copyir copyir.comcom 2 Check the MFPB connector for proper connection and correct as necessary copyir copyir.comcom 3 Change scanner unit copyir copyir.comcom 4 Change MFPB copyir copyir.comcom
3C00 Trouble related to security
3C10 Trouble related to security
3C40 Trouble related to security
3FFF Flash ROM write error 1 Check the cable and connector for proper connection and correct as necessary copyir copyir.comcom 2 Identify the specific firmware that is responsible for the error copyir copyir.comcom 3 Rewrite the firmware copyir copyir.comcom 4 Unplug parameter chip from PRCB and then plug it back in copyir copyir.comcom 5 Change PRCB copyir copyir.comcom 6 Change MFPB copyir copyir.comcom - Scanner home sensor abnormalities 1 Check to see if the lock lever of the Scanner unit is unlocked and unlock the lock lever if it is locked copyir.com 2 Check the M101 connector for proper connection and correct as necessary copyir.com 3 Check M101 for proper drive coupling and correct as necessary copyir.com 4 Check the PRCB connector for proper connection and correct as necessary copyir.com 5 M101 operation check copyir.com MFPB P2-1 to 4 1680MF: J-12 1690MF: J-6 copyir.com 6 Change PRCB copyir.com 7 Change DCPU copyir.com
0F51 Waste toner full sensor malfunction
• It is determined that the LED and photo receiver are faulty through a check made when a new imaging cartridge is detected copyir.com 1 Check the PRCB connector for proper connection and correct as necessary copyir.com 2 PS7 sensor check copyir.com 3 Change imaging cartridge copyir.com 4 Change PRCB copyir.com
1038 Engine connect error 1 Turn OFF and ON the power switch copyir.com 2 Check the PRCB connector for proper connection and correct as necessary copyir.com 3 Check the MFPB connector for proper connection and correct as necessary copyir.com 4 Check for proper connection between PRCB and MFPB and correct as necessary copyir.com 5 Change MFPB copyir.com 6 Change PRCB copyir.com
13C0 Print control board malfunction
• A communication error occurs in print control board (PRCB) copyir.com 1 Reboot the main body copyir.com 2 Change PRCB copyir.com
13DD Backup data error
• The printer determines that EEPROM is yet to be mounted when the main power switch is turned ON copyir.com 1 Check the cable and connector for proper connection and correct as necessary copyir.com 2 Change PRCB copyir.com 3 Change MFPB copyir.com
13E2 Engine flash ROM write error
• Flash ROM writing is found faulty during a check copyir.com 1 Check the cable and connector for proper connection and correct as necessary copyir.com 2 Change PRCB copyir.com 3 Change MFPB copyir.com
13F0 Engine control failure
• An undefined malfunction occurs in the engine section (PRCB, etc copyir.com) copyir.com 1 Check the cable and connector for proper connection and correct as necessary copyir.com 2 Change PRCB copyir.com 3 Change MFPB copyir.com
14A3 IR lamp malfunction 1 Check the exposure lamp for lighting condition when the power switch is turned ON and, if any faulty symptom is evident, correct the Scanner Unit copyir.com 2 Check the MFPB connector for proper connection and correct as necessary copyir.com 3 Change scanner unit copyir.com 4 Change MFPB copyir.com
3C00 Trouble related to security
3C10 Trouble related to security
3C40 Trouble related to security
3FFF Flash ROM write error 1 Check the cable and connector for proper connection and correct as necessary copyir.com 2 Identify the specific firmware that is responsible for the error copyir.com 3 Rewrite the firmware copyir.com 4 Unplug parameter chip from PRCB and then plug it back in copyir.com 5 Change PRCB copyir.com 6 Change MFPB copyir.com