04H    Printer control board malfunction
• Communications with the M/C expansion IO G/A (IC on the printer control board) are not properly carried out     copyir.com    1 Check the PRCB connector for proper connection and correct as necessary     copyir.com 2 Change PRCB     copyir.com
05H    Flash ROM malfunction
• Engine firmware upgrading has failed     copyir.com    1 Check the PRCB connector for proper connection and correct as necessary     copyir.com 2 Change PRCB     copyir.com
08H    Main motor malfunction
• The motor lock signal remains HIGH for a predetermined consecutive period of time while the main motor remains energized     copyir.com • The motor lock signal remains LOW for a predetermined consecutive period of time while the main motor remains deenergized     copyir.com    1 Check the M1 connector for proper connection and correct as necessary     copyir.com 2 Check M1 for proper drive coupling and correct as necessary     copyir.com 3 Check the PRCB connector for proper connection and correct as necessary     copyir.com 4 M1 operation check     copyir.com PRCB PJ8PRCB-5 (REM) PRCB PJ8PRCB-8 (LOCK) C-4     copyir.com 5 Change PRCB     copyir.com 6 Change DCPU1     copyir.com
0BH    Ventilation fan motor malfunction
• The fan motor lock signal remains HIGH for a predetermined consecutive period of time while the ventilation fan motor remains energized     copyir.com    1 Check the FM2 connector for proper connection and correct as necessary     copyir.com 2 Check FM2 for proper drive coupling and correct as necessary     copyir.com 3 Check the PRCB connector for proper connection and correct as necessary     copyir.com 4 FM2 operation check     copyir.com PRCB PJ10PRCB-1 (REM) PECB PJ10PRCB-3 (LOCK) C-4     copyir.com 5 Change PRCB     copyir.com 6 Change DCPU1     copyir.com
0CH    Power supply cooling fan motor malfunction
• The fan motor lock signal remains HIGH for a predetermined consecutive period of time while the power supply cooling fan motor remains energized     copyir.com    1 Check the FM1 connector for proper connection and correct as necessary     copyir.com 2 Check FM1 for proper drive coupling and correct as necessary     copyir.com 3 Check the PRCB connector for proper connection and correct as necessary     copyir.com 4 M1 operation check     copyir.com PRCB PJ4PRCB-1 (REM) PRCB PJ4PRCB-3 (LOCK) C-2     copyir.com 5 Change PRCB     copyir.com 6 Change DCPU1     copyir.com
0FH    Duplex cooling fan motor malfunction
101H    Scanner motor malfunction
• A low motor lock signal is not detected even after the lapse of a predetermined period of time after the scanner motor has been started     copyir.com • The motor lock signal remains HIGH for a predetermined consecutive period of time while the scanner motor remains energized     copyir.com    1 Check to see if the lock lever of the Scanner unit is unlocked and unlock the lock lever if it is locked     copyir.com 2 Check the M5 connector for proper connection and correct as necessary     copyir.com 3 Check M5 for proper drive coupling and correct as necessary     copyir.com 4 Check the PRCB connector for proper connection and correct as necessary     copyir.com 5 M5 operation check     copyir.com IPB J9IPB-1 to 4 (Pulse Output) L-10     copyir.com 6 Change PRCB     copyir.com 7 Change DCPU2     copyir.com 8 Change DCPU1     copyir.com
102H    Faulty ir exposure lamp
• The intensity of the light emitted from the exposure lamp of the scanner falls short of the specified value     copyir.com    1 Check the exposure lamp for lighting condition when the power switch is turned ON and, if any faulty symptom is evident, correct the Scanner Unit     copyir.com 2 Check the PRCB connector for proper connection and correct as necessary     copyir.com 3 Change scanner unit     copyir.com 4 Change PRCB     copyir.com
10H    Polygon motor malfunction
• A low motor lock signal is not detected even after the lapse of a predetermined period of time after the polygon motor has been started     copyir.com • The motor lock signal remains HIGH for a predetermined consecutive period of time while the polygon motor remains energized     copyir.com    1 Check the cable and connector for proper connection and correct as necessary     copyir.com 2 Change PH unit     copyir.com 3 Change PRCB     copyir.com
12H    Laser malfunction
• The SOS signal is not detected within a predetermined period of time after the output of a laser has been started     copyir.com • The SOS signal is never detected in the image area     copyir.com    1 Check the cable and connector for proper connection and correct as necessary     copyir.com 2 Change PH unit     copyir.com 3 Change PRCB     copyir.com
14H    2nd image transfer pressure /retraction failure
• The state of the retraction position sensor/2nd image transfer is not changed from the unblocked to blocked state even after the lapse of a predetermined period of time during predrive     copyir.com • The retraction position sensor/2nd image transfer is in the unblocked state even after the lapse of a predetermined period of time during predrive     copyir.com • The retraction position sensor/2nd image transfer is not blocked (roller in the retracted position) within a predetermined period of time after the retraction sequence of the 2nd transfer roller has been started     copyir.com • The retraction position sensor/2nd image transfer is not unblocked (roller in the pressed position) within a predetermined period of time after the pressure sequence of the 2nd transfer roller has been started     copyir.com    1 Check the M1 connector for proper connection and correct as necessary     copyir.com 2 Check M1 for proper drive coupling and correct as necessary     copyir.com 3 Check the SD4 connector for proper connection and correct as necessary     copyir.com 4 Check the PRCB connector for proper connection and correct as necessary     copyir.com 5 PS5 sensor check     copyir.com PRCB PJ14PRCB-3 (ON) J to K-3     copyir.com 6 SD4 operation check     copyir.com PRCB PJ11PRCB-2 (REM) J to K-1     copyir.com 7 M1 operation check     copyir.com PRCB PJ8PRCB-5 (REM) PRCB PJ8PRCB-8 (LOCK) C-4     copyir.com 8 Change PRCB     copyir.com
15H    Cleaning blade pressure /retraction failure
• The state of the retraction position sensor/cleaning blade is not changed from the blocked to unblocked state even after the lapse of a predetermined period of time during predrive     copyir.com • The retraction position sensor/cleaning blade is in the blocked state even after the lapse of a predetermined period of time during predrive     copyir.com • The retraction position sensor/cleaning blade is not unblocked (blade in the retracted position) within a predetermined period of time after the retraction sequence of the cleaning blade has been started     copyir.com • The retraction position sensor/cleaning blade is not blocked (blade in the pressed position) within a predetermined period of time after the pressure sequence of the cleaning blade has been started     copyir.com    1 Check the M1 connector for proper connection and correct as necessary     copyir.com 2 Check M1 for proper drive coupling and correct as necessary     copyir.com 3 Check the SD3 connector for proper connection and correct as necessary     copyir.com 4 Check the PRCB connector for proper connection and correct as necessary     copyir.com 5 PS6 sensor check     copyir.com PRCB PJ9PRCB-11 (ON) C-5     copyir.com 6 SD3 operation check     copyir.com PRCB PJ10PRCB-5 (REM) C-3     copyir.com 7 M1 operation check     copyir.com PRCB PJ8PRCB-5 (REM) PRCB PJ8PRCB-8 (LOCK) C-4     copyir.com 8 Change PRCB     copyir.com
16H    Transfer belt rotation failure
• The belt positioning sensor does not detect the transfer belt position detection hole a second time even after the lapse of a predetermined period of time after it has detected one while the transfer belt is rotated     copyir.com    1 Check the PRCB connector for proper connection and correct as necessary     copyir.com 2 PS4 sensor check     copyir.com PRCB PJ9PRCB-8 (ON) C-5     copyir.com 3 Change transfer belt unit     copyir.com 4 Change PRCB     copyir.com
17H    Rack rotation failure
• The rack positioning sensor is in the blocked state when the rack motor remains deenergized     copyir.com • The rack positioning sensor is not blocked a second time even after the lapse of a predetermined period of time after it has been blocked once while the rack motor remains energized     copyir.com • The rack positioning sensor is unable to detect the deceleration control position after the lapse of a given period of time after the rack motor has started while the rack motor is turning     copyir.com • The count value of the edge of ON signal of the rack positioning sensor during each developing positions are not a predetermined value while the rack motor is turning     copyir.com    1 Check the M2 connector for proper connection and correct as necessary     copyir.com 2 Check M2 for proper drive coupling and correct as necessary     copyir.com 3 Check the PRCB connector for proper connection and correct as necessary     copyir.com 4 PS3 sensor check     copyir.com PRCB PJ5PRCB-11 (ON) C-6 5 M2 operation check     copyir.com PRCB PJ5PRCB-1 to 4 (Pulse Output) C-6 to 7     copyir.com 6 Change PRCB     copyir.com
18H    Heating roller warm-up failure
• The thermistor does not detect a predetermined temperature value even after the lapse of a predetermined period of time after the current warm-up cycle has been started and the current warm-up cycle is thus not completed     copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)     copyir.com 2 Check the fusing unit, DCPU1, and PRCB for proper connection and correct as necessary     copyir.com 3 Check the lever of the safety switch and correct as necessary     copyir.com 4 Change the fusing unit     copyir.com 5 Change PRCB     copyir.com 6 Change DCPU1     copyir.com
19H    Abnormally low heating roller temperature
• The temperature detected by the thermistor remains lower than a predetermined value for a predetermined period of time     copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)     copyir.com 2 Check the fusing unit, DCPU1, and PRCB for proper connection and correct as necessary     copyir.com 3 Check the lever of the safety switch and correct as necessary     copyir.com 4 Change the fusing unit     copyir.com 5 Change PRCB     copyir.com 6 Change DCPU1     copyir.com
1AH    Abnormally high heating roller temperature
• The temperature detected by the thermistor is a predetermined value or higher for a predetermined period of time     copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)     copyir.com 2 Check the fusing unit, DCPU1, and PRCB for proper connection and correct as necessary     copyir.com 3 Check the lever of the safety switch and correct as necessary     copyir.com 4 Change the fusing unit     copyir.com 5 Change PRCB     copyir.com 6 Change DCPU1     copyir.com
1BH    Faulty thermistor
• The condition of a temperature rise of less than 1°C extends continuously for a predetermined period of time that begins when the warm-up cycle is started     copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)     copyir.com 2 Check the fusing unit, DCPU1, and PRCB for proper connection and correct as necessary     copyir.com 3 Check the lever of the safety switch and correct as necessary     copyir.com 4 Change the fusing unit     copyir.com 5 Change PRCB     copyir.com 6 Change DCPU1     copyir.com
21H    Faulty OHP sensor
• It is determined that the OHP sensor is faulty through a check made at the end of the predrive     copyir.com    1 Check the PRCB connector for proper connection and correct as necessary     copyir.com 2 PS2 sensor check     copyir.com PRCB PJ12PRCB-6 (ON) J to K-2     copyir.com 3 Change PRCB     copyir.com
23H    Faulty waste toner near full detection board
• It is determined that the LED and photo receiver are faulty through a check made when a new drum cartridge is detected     copyir.com    1 Check the WTDTB/LED connector for proper connection and correct as necessary     copyir.com 2 Check the PRCB connector for proper connection and correct as necessary     copyir.com 3 Change the drum cartridge     copyir.com 4 Change WTDTB/LED     copyir.com 5 Change PRCB     copyir.com
24H    Faulty fusing thermistor resistor
• The heater lamp remains ON for a predetermined consecutive period of time     copyir.com
29H    Trouble related to security
2AH    Trouble related to security
2BH    Trouble related to security
2CH    Trouble related to security
31H    IR cooling fan motor malfunction
• The fan motor lock signal remains HIGH for a predetermined consecutive period of time while the cooling fan motor remains energized     copyir.com    1 Check the FM3 connector for proper connection and correct as necessary     copyir.com 2 Check FM3 for proper drive coupling and correct as necessary     copyir.com 3 Check the PRCB connector for proper connection and correct as necessary     copyir.com 4 FM3 operation check     copyir.com IPB J22IPB-1 (ON) IPB J22IPB-3 (LOCK) L-9     copyir.com 5 Change PRCB     copyir.com 6 Change DCPU2     copyir.com 7 Change DCPU1     copyir.com