کو نیکا مینو لتا magicolor5440dl
0010H Color PC Drum Motor malfunction
• The Color PC Drum Motor does not rotate evenly even after the lapse of a given period of time while it is being started copyir.com • The Motor Lock signal remains HIGH for a given period of consecutive time while the Color PC Drum Motor is being rotated copyir.com 1 Check the M2 connector for proper connection and correct as necessary copyir.com 2 Check M2 for proper drive coupling and correct as necessary copyir.com 3 Check the PWB-A connector for proper connection and correct as necessary copyir.com 4 M2 operation check PWB-A PJ14A-8 (LOCK) PWB-A PJ14A-5 (REM) 11-B copyir.com 5 Change PWB-A copyir.com 6 Change LV copyir.com
0017H Intermediate Transport Motor malfunction
• The Intermediate Transport Motor does not rotate evenly even after the lapse of a given period of time while it is being started copyir.com • The Motor Lock signal remains HIGH for a given period of consecutive time while the Intermediate Transport Motor is being rotated copyir.com 1 Check the M3 connector for proper connection and correct as necessary copyir.com 2 Check M3 for proper drive coupling and correct as necessary copyir.com 3 Check the PWB-A connector for proper connection and correct as necessary copyir.com 4 M3 operation check PWB-A PJ27A-8 (LOCK) PWB-A PJ27A-5 (REM) 2-I copyir.com 5 Change PWB-A copyir.com 6 Change LV copyir.com
0018H Developing Motor/K malfunction
• The Developing Motor/K does not rotate evenly even after the lapse of a given period of time while it is being started copyir.com • The Motor Lock signal remains HIGH for a given period of consecutive time while the Developing Motor/K is being rotated copyir.com 1 Check the M5 connector for proper connection and correct as necessary copyir.com 2 Check M5 for proper drive coupling and correct as necessary copyir.com 3 Check the PWB-A connector for proper connection and correct as necessary copyir.com 4 M5 operation check PWB-A PJ33A-8 (LOCK) PWB-A PJ33A-5 (REM) 11-C copyir.com 5 Change PWB-A copyir.com 6 Change LV copyir.com
001BH Developing Motor/Y,M,C malfunction
• The Developing Motor/Y,M,C does not rotate evenly even after the lapse of a given period of time while it is being started copyir.com • The Motor Lock signal remains HIGH for a given period of consecutive time while the Developing Motor/Y,M,C is being rotated copyir.com 1 Check the M1 connector for proper connection and correct as necessary copyir.com 2 Check M1 for proper drive coupling and correct as necessary copyir.com 3 Check the PWB-A connector for proper connection and correct as necessary copyir.com 4 M1 operation check PWB-A PJ8A-8 (LOCK) PWB-A PJ8A-5 (REM) 11-A/ 5 Change PWB-A copyir.com 6 Change LV copyir.com
0046H Fusing Cooling Fan Motor malfunction
• The Motor Lock signal remains HIGH for a given period of consecutive time while the Fusing Cooling Fan Motor is being rotated copyir.com 1 Check the M11 connector for proper connection and correct as necessary copyir.com 2 Check the fan for possible overload and correct as necessary copyir.com 3 M11 operation check PWB-A PJ21A-3 (LOCK) PWB-A PJ21A-1 (ON) 2-F-E 4 Change PWB-A copyir.com
004CH Ozone Ventilation Fan Motor malfunction
• The Motor Lock signal remains HIGH for a given period of consecutive time while the Ozone Ventilation Fan Motor is being rotated copyir.com 1 Check the M12 connector for proper connection and correct as necessary copyir.com 2 Check the fan for possible overload and correct as necessary copyir.com 3 M12 operation check PWB-A PJ6A-7 (LOCK) PWB-A PJ6A-5 (ON) 14-I copyir.com 4 Change PWB-A copyir.com
004EH LV Cooling Fan Motor malfunction
• The Motor Lock signal remains HIGH for a given period of consecutive time while the LV Cooling Fan Motor is being rotated copyir.com • The Fusing Motor does not rotate evenly even after the lapse of a given period of time while it is being started copyir.com 1 Check the M10 connector for proper connection and correct as necessary copyir.com 2 Check the fan for possible overload and correct as necessary copyir.com 3 M10 operation check PWB-A PJ9A-3 (LOCK) PWB-A PJ9A-1 (ON) 12-J copyir.com 4 Change PWB-A copyir.com
0060H Fusing Motor malfunction
• The Motor Lock signal remains HIGH for a given period of consecutive time while the Fusing Motor is being rotated copyir.com 1 Check the M4 connector for proper connection and correct as necessary copyir.com 2 Check the Fusing Unit driving mechanism for possible overload and correct as necessary copyir.com 3 Check the PWB-A connector for proper connection and correct as necessary copyir.com 4 M4 operation check PWB-A PJ19A-8 (LOCK) PWB-A PJ19A-5 (REM) 2-B-C 5 Change PWB-A copyir.com
0094H 2nd image transfer pressure/ retraction failure
• The Retraction Position Sensor/2nd Image Transfer is not activated (retracted position) within a given period of time after the retraction sequence of the 2nd Transfer Roller has been started copyir.com • The Retraction Position Sensor/2nd Image Transfer is not deactivated (pressed position) within a given period of time after the pressure sequence of the 2nd Transfer Roller has been started copyir.com 1 Check the M3 connector for proper connection and correct as necessary copyir.com 2 Check the CL5 connector for proper connection and correct as necessary copyir.com 3 Check M3 for proper drive coupling and correct as necessary copyir.com 4 Check CL5 for proper drive coupling and correct as necessary copyir.com 5 Check the PWB-A connector for proper connection and correct as necessary copyir.com 6 PC10 sensor check PWB-A PJ10A-6 (ON) 7-A copyir.com 7 CL5 operation check PWB-A PJ10A-8 (ON) 7-A copyir.com 8 M3 operation check PWB-A PJ27A-8 (LOCK) PWB-A PJ27A-5 (REM) 2-I copyir.com 9 Change PWB-A copyir.com
0096H 1st image transfer pressure/ retraction failure
• The Retraction Position Sensor/1st Image Transfer is not activated (retracted position) within a given period of time after the Intermediate Transport Motor has started rotating copyir.com • The Retraction Position Sensor/1st Image Transfer is not deactivated (pressed position) within a given period of time after the Intermediate Transport Motor has started rotating copyir.com 1 Check the M3 connector for proper connection and correct as necessary copyir.com 2 Check the CL4 connector for proper connection and correct as necessary copyir.com 3 Check M3 for proper drive coupling and correct as necessary copyir.com 4 Check CL4 for proper drive coupling and correct as necessary copyir.com 5 Check the PWB-A connector for proper connection and correct as necessary copyir.com 6 PC9 sensor check PWB-A PJ7A-13 (ON) 7-B-C copyir.com 7 CL4 operation check PWB-A PJ7A-10 (ON) 7-B copyir.com 8 M3 operation check PWB-A PJ27A-8 (LOCK) PWB-A PJ27A-5 (REM) 2-I copyir.com 9 Change PWB-A copyir.com
0300H Polygon Motor malfunction
• The Polygon Motor does not rotate evenly even after the lapse of a given period of time after it has been started copyir.com • The Motor Lock signal remains HIGH for a given period of consecutive time while the Polygon Motor is being rotated copyir.com 1 Check the cable and connector for proper connection and correct as necessary copyir.com 2 Change PH Unit copyir.com 3 Change PWB-A copyir.com
0310H Laser malfunction
• The SOS signal is not detected within a given period of time after the output of the laser has been started copyir.com 1 Check the cable and connector for proper connection and correct as necessary copyir.com 2 Change PH Unit copyir.com 3 Change PWB-A copyir.com
0500H Heating Roller warm-up failure
• The Heating Roller Thermistor does not detect the specified temperature and the warm-up cycle is not completed even after the lapse of a given period of time after the cycle has been started copyir.com 1 Check the Fusing Unit for correct installation (whether it is secured in position) copyir.com 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary copyir.com 3 Change Fusing Unit copyir.com 4 Change PWB-A copyir.com 5 Change LV copyir.com
0501H Fusing Pressure Roller warm-up failure
• The Fusing Pressure Roller Thermistor does not detect the specified temperature and the warm-up cycle is not completed even after the lapse of a given period of time after the cycle has been started copyir.com 1 Check the Fusing Unit for correct installation (whether it is secured in position) copyir.com 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary copyir.com 3 Change Fusing Unit copyir.com 4 Change PWB-A copyir.com 5 Change LV copyir.com
0510H Abnormally low Heating Roller temperature
• The temperature detected by the Heating Roller Thermistor remains lower than the specified value for a given period of time or longer copyir.com 1 Check the Fusing Unit for correct installation (whether it is secured in position) copyir.com 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary copyir.com 3 Change Fusing Unit copyir.com 4 Change PWB-A copyir.com 5 Change LV copyir.com
0511H Abnormally low Fusing Pressure Roller temperature
• The temperature detected by the Fusing Pressure Roller Thermistor remains lower than the specified value for a given period of time or longer copyir.com 1 Check the Fusing Unit for correct installation (whether it is secured in position) copyir.com 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary copyir.com 3 Change Fusing Unit copyir.com 4 Change PWB-A copyir.com 5 Change LV copyir.com
0520H Abnormally high Heating Roller temperature
• The temperature detected by the Heating Roller Thermistor remains higher than the specified value for a given period of time or longer copyir.com 1 Check the Fusing Unit for correct installation (whether it is secured in position) copyir.com 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary copyir.com 3 Change Fusing Unit copyir.com 4 Change PWB-A copyir.com 5 Change LV copyir.com
0521H Abnormally high Fusing Pressure Roller temperature
• The temperature detected by the Fusing Pressure Roller Thermistor remains higher than the specified value for a given period of time or longer copyir.com 1 Check the Fusing Unit for correct installation (whether it is secured in position) copyir.com 2 Check the Fusing Unit, LV, and PWB-A for proper connection and correct as necessary copyir.com 3 Change Fusing Unit copyir.com 4 Change PWB-A copyir.com 5 Change LV copyir.com
13D0H Parameter Chip failure
• Data, which has been written, is read, checked, and found faulty; rewriting of the data is then executed and the data is checked to be found faulty during re-reading copyir.com • A count value is found faulty during reading copyir.com • Parameter Chip is detected to be not mounted during initial mounting detecting sequence copyir.com • Found to be access failure copyir.com 1 Unplug the power cord and plug it in, then turn OFF and ON the Power Switch copyir.com 2 Check Parameter Chip (IC15) on PWB-A for proper connection and correct as necessary copyir.com 3 Change PWB-A copyir.com 4 Change Parameter Chip copyir.com
13E2H Flash ROM write error
• Flash ROM writing is found faulty during a check copyir.com 1 Change PWB-A copyir.com
13E3H Flash ROM device fault
• An erase error occurs during erasing of data in Flash ROM copyir.com 1 Change PWB-A copyir.com
C002 RAM error 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer copyir.com) 2 Check connection state of the extension memory and correct as necessary copyir.com 3 Check the PWB-P connector for proper connection and correct as necessary copyir.com 4 Changethe extension memory copyir.com 5 Change PWB-P copyir.com
C003 RAM error 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer copyir.com) 2 Check connection state of the extension memory and correct as necessary copyir.com 3 Check the PWB-P connector for proper connection and correct as necessary copyir.com 4 Changethe extension memory copyir.com 5 Change PWB-P copyir.com
C013 MAC address 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer copyir.com) 2 Check the PWB-P connector for proper connection and correct as necessary copyir.com 3 Change PWB-P copyir.com
C015 BOOT ROM error 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer copyir.com) 2 Check the PWB-P connector for proper connection and correct as necessary copyir.com 3 Change PWB-P copyir.com
C022 NVRAM error 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer copyir.com) 2 Check the PWB-P connector for proper connection and correct as necessary copyir.com 3 Change PWB-P copyir.com
C025 Controller ROM error 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer copyir.com) 2 Check the PWB-P connector for proper connection and correct as necessary copyir.com 3 If this error message is displayed after update of firmware, conduct the firmware update procedures again copyir.com 4 Change PWB-P copyir.com
C026 Controller ROM error 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer copyir.com) 2 Check the PWB-P connector for proper connection and correct as necessary copyir.com 3 If this error message is displayed after update of firmware, conduct the firmware update procedures again copyir.com 4 Change PWB-P copyir.com
C027 Controller ROM error 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer copyir.com) 2 Check the PWB-P connector for proper connection and correct as necessary copyir.com 3 If this error message is displayed after update of firmware, conduct the firmware update procedures again copyir.com 4 Change PWB-P copyir.com
C050 Hard disk access error 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer copyir.com) 2 Check the HDD connector for proper connection and correct as necessary copyir.com 3 Check the PWB-P connector for proper connection and correct as necessary copyir.com 4 Change HDD copyir.com 5 Change PWB-P copyir.com
C051 Hard disk full error 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer copyir.com) 2 Delete the job hold in PROOF/PRINT MENU to increase the available range for user space copyir.com 3 Check the HDD connector for proper connection and correct as necessary copyir.com 4 Format HDD with “SYS DEFAULT MENU/HDD FORMAT copyir.com 5 Change HDD copyir.com
C060 Firmware Update error 1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer copyir.com) 2 Check the cable that has been used for update of the firmware for proper connection and correct as necessary copyir.com 3 Update the firmware again copyir.com 4 Check the PWB-P connector for proper connection and correct as necessary copyir.com 5 Change PWB-P copyir.com
