کو نیکا مینو لتا magicolor7450ii

0001    Main Motor turning at abnormal timing
• The Motor Lock signal remains LOW for a predetermined continuous period of time while the Motor remains stationary     copyir.com    1 M1 operation check PWB-M CNDM1-5 (REM) PWB-M CNDM1-8 (LOCK) K to L-2     copyir.com 2 Change PWB-M     copyir.com 3 Change PU1     copyir.com
0018    Color PC Drum Motor’s failure to turn
• The Motor Lock signal remains HIGH for a predetermined continuous period of time while the Motor is turning     copyir.com    1 Check the connector of motor for proper connection and correct as necessary     copyir.com 2 Check the connector of motor for proper drive coupling and correct as necessary     copyir.com 3 Check the PWB-M connector for proper connection and correct as necessary     copyir.com 4 M2 operation check PWB-M CNDM3-5 (REM) PWB-M CNDM3-8 (LOCK) C-23     copyir.com 5 Change PWB-M     copyir.com
0019    Color PC Drum Motor’s turning at abnormal timing
• The Motor Lock signal remains LOW for a predetermined continuous period of time while the Motor remains stationary    1 M2 operation check PWB-M CNDM3-5 (REM) PWB-M CNDM3-8 (LOCK) C-23     copyir.com 2 Change PWB-M     copyir.com
001A    Color Developing Motor’s failure to turn
• The Motor Lock signal remains HIGH for a predetermined continuous period of time while the Motor is turning     copyir.com    1 Check the connector of motor for proper connection and correct as necessary     copyir.com 2 Check the connector of motor for proper drive coupling and correct as necessary     copyir.com 3 Check the PU1 connector for proper connection and correct as necessary     copyir.com 4 Check the PWB-M connector for proper connection and correct as necessary     copyir.com 5 M3 operation check PWB-M CNDM2-5 (REM) PWB-M CNDM2-8 (LOCK) C-22     copyir.com 6 Change PU1     copyir.com 7 Change PWB-M     copyir.com
001B    Color Developing Motor’s turning at abnormal timing
• The Motor Lock signal remains LOW for a predetermined continuous period of time while the Motor remains stationary     copyir.com    1 M3 operation check PWB-M CNDM2-5 (REM) PWB-M CNDM2-8 (LOCK) C-22     copyir.com 2 Change PU1     copyir.com 3 Change PWB-M     copyir.com
0040    Suction Fan Motor’s failure to turn
• The Fan Lock signal remains HIGH for a predetermined continuous period of time while the Motor remains stationary     copyir.com    1 Check the connector of motor for proper connection and correct as necessary     copyir.com 2 Change the Right Door Assy     copyir.com 3 Change PWB-M     copyir.com
0043    Cooling Fan Motor/1’s failure to turn
• The Fan Lock signal remains HIGH for a predetermined continuous period of time while the Motor remains stationary     copyir.com    1 Check the connector of motor for proper connection and correct as necessary     copyir.com 2 Check the fan for possible overload and correct as necessary     copyir.com 3 M12 operation check PWB-M CNDM2-15 (ON) PWB-M CNDM2-16 (LOCK) C-22     copyir.com 4 Change PWB-M7     copyir.com
0046    Fusing Cooling Fan Motor/1’s failure to turn
• The Fan Lock signal remains HIGH for a predetermined continuous period of time while the Motor remains stationary     copyir.com    1 Check the connector of motor for proper connection and correct as necessary     copyir.com 2 Check the fan for possible overload and correct as necessary     copyir.com 3 M11 operation check PWB-M CNDM1-12 (ON) PWB-M CNDM1-14 (LOCK) K to L-1 to 2     copyir.com 4 Change PWB-M     copyir.com
0048    Fusing Cooling Fan Motor/2’s failure to turn
• The Fan Lock signal remains HIGH for a predetermined continuous period of time while the Motor remains stationary    1 Check the connector of motor for proper connection and correct as necessary     copyir.com 2 Check the fan for possible overload and correct as necessary     copyir.com 3 M13 operation check PWB-M CNDM1-14 (ON) PWB-M CNDM1-17 (LOCK) K to L-1     copyir.com 4 Change PWB-M     copyir.com
004C    Ozone Ventilation Fan Motor’s failure to turn
• The Fan Lock signal remains HIGH for a predetermined continuous period of time while the Motor remains stationary     copyir.com    1 Check the connector of motor for proper connection and correct as necessary     copyir.com 2 Check the fan for possible overload and correct as necessary     copyir.com 3 M14 operation check PWB-M CNLP-9 (ON) PWB-M CNLP-11 (LOCK) C-11     copyir.com 4 Change PWB-M     copyir.com
004E    Power Supply Cooling Fan Motor/1’s failure to turn
• The Fan Lock signal remains HIGH for a predetermined continuous period of time while the Motor remains stationary     copyir.com    1 Check the connector of motor for proper connection and correct as necessary     copyir.com 2 Check the fan for possible overload and correct as necessary     copyir.com 3 M8 operation check PWB-M CNLV-2 (ON) PWB-M CNLV-3 (LOCK) C-27     copyir.com 4 Change PU1     copyir.com
004F    Cooling Fan Motor 2’s failure to turn
• The Fan Lock signal remains HIGH for a predetermined continuous period of time while the Motor remains stationary     copyir.com    1 Check the connector of motor for proper connection and correct as necessary     copyir.com 2 Check the fan for possible overload and correct as necessary     copyir.com 3 M22 operation check PWB-M CNR2FAN-4 (ON) PWB-M CNR2FAN-6 (LOCK) L-22     copyir.com 4 Change PWB-M     copyir.com
0094    2nd Image Transfer Roller Separation
• The 2nd Image Transfer Pressure Position Sensor doesn’t turn ON (Retracting) even after the lapse of a given period of time after the 2nd Image Transfer Pressure/Retraction Motor has started rotating during the 2nd Image Transfer Roller is retracting     copyir.com • The 2nd Image Transfer Pressure Position Sensor doesn’t turn OFF (Pressuring) even after the lapse of a given period of time after the 2nd Image Transfer Pressure/Retraction Motor has started rotating during the 2nd Image Transfer Roller is pressuring     copyir.com    1 Check the connector of motor for proper connection and correct as necessary     copyir.com 2 Change the Right Door Assy 3 Change PWB-M     copyir.com
0096    Transfer Belt Separation
• The 1st Image Transfer Pressure/Retraction Position Sensor doesn’t turn ON (Retracting) even after the lapse of a given period of time after the 1st Image Transfer Pressure/Retraction Clutch has turned ON during the Transfer Belt is retracting     copyir.com • The 1st Image Transfer Pressure/Retraction Position Sensor doesn’t turn OFF (Pressuring) even after the lapse of a given period of time after the 1st Image Transfer Pressure/Retraction Clutch has turned ON during the Transfer Belt is pressuring     copyir.com    1 Check the M1 connector for proper connection and correct as necessary     copyir.com 2 PC6 I/O check, Sensor check 3 CL3 operation check PWB-M CNDM1-11 (ON) K to L-2     copyir.com 4 M1 operation check PWB-M CNDM1-5 (REM) PWB-M CNDM1-8 (LOCK) K to L-2     copyir.com 5 Change PWB-M     copyir.com
0301    Polygon Motor/C failure to turn
• The Polygon motor fails to turn stably even after the lapse of a given period of time after activating the Polygon motor     copyir.com • Motor Lock signal detects H for a given period time consecutively during the Polygon motor is rotating     copyir.com    1 Check the connector for proper connection and correct as necessary     copyir.com 2 Change PH Unit     copyir.com 3 Change PWB-D     copyir.com 4 Change PWB-M7     copyir.com
0302    Polygon Motor/M failure to turn
• The Polygon motor fails to turn stably even after the lapse of a given period of time after activating the Polygon motor     copyir.com • Motor Lock signal detects H for a given period time consecutively during the Polygon motor is rotating     copyir.com    1 Check the connector for proper connection and correct as necessary     copyir.com 2 Change PH Unit     copyir.com 3 Change PWB-D     copyir.com 4 Change PWB-M7     copyir.com
0303    Polygon Motor/Y failure to turn
• The Polygon motor fails to turn stably even after the lapse of a given period of time after activating the Polygon motor     copyir.com • Motor Lock signal detects H for a given period time consecutively during the Polygon motor is rotating     copyir.com    1 Check the connector for proper connection and correct as necessary     copyir.com 2 Change PH Unit     copyir.com 3 Change PWB-D     copyir.com 4 Change PWB-M7     copyir.com
0304    Polygon Motor/K failure to turn
• The Polygon motor fails to turn stably even after the lapse of a given period of time after activating the Polygon motor     copyir.com • Motor Lock signal detects H for a given period time consecutively during the Polygon motor is rotating     copyir.com    1 Check the connector for proper connection and correct as necessary     copyir.com 2 Change PH Unit     copyir.com 3 Change PWB-D     copyir.com 4 Change PWB-M7     copyir.com
0311    Laser malfunction (Cyan)
• SOS signal is not detected even after the lapse of a given period of time after staring the laser output     copyir.com • SOS signal is not detected for a given period of time during printing or IDC sensor adjustment     copyir.com    1 Check the connector for proper connection and correct as necessary     copyir.com 2 Change PH Unit     copyir.com 3 Change PWB-D     copyir.com 4 Change PWB-M7     copyir.com
0312    Laser malfunction (Magenta)
• SOS signal is not detected even after the lapse of a given period of time after staring the laser output     copyir.com • SOS signal is not detected for a given period of time during printing or IDC sensor adjustment     copyir.com    1 Check the connector for proper connection and correct as necessary     copyir.com 2 Change PH Unit     copyir.com 3 Change PWB-D     copyir.com 4 Change PWB-M7     copyir.com
0313    Laser malfunction (Yellow)
• SOS signal is not detected even after the lapse of a given period of time after staring the laser output     copyir.com • SOS signal is not detected for a given period of time during printing or IDC sensor adjustment     copyir.com    1 Check the connector for proper connection and correct as necessary     copyir.com 2 Change PH Unit     copyir.com 3 Change PWB-D     copyir.com 4 Change PWB-M7     copyir.com
0314    Laser malfunction (Black)
• SOS signal is not detected even after the lapse of a given period of time after staring the laser output     copyir.com • SOS signal is not detected for a given period of time during printing or IDC sensor adjustment     copyir.com    1 Check the connector for proper connection and correct as necessary     copyir.com 2 Change PH Unit     copyir.com 3 Change PWB-D     copyir.com 4 Change PWB-M7     copyir.com
0500    Heating Roller warm-up failure
• The Heating Roller Thermistor/1 (TH1) and the Heating Roller Thermistor/2 (TH3) fails to raise a given degree of temperature even after the lapse of a given period of time after the Heating Roller Heater lamp/1 (H1) is turned ON     copyir.com • The detected temperature of the Heating Roller Thermistor/1 (TH1) is lower for a given level of degree than one of the Fusing Pressure Roller Thermistor/1 (TH2) after the Front Door is opened or closed, the Main Power Switch is turned ON or TROUBLE RESET is implemented     copyir.com • The counter value of zero cross signal input is not updated for a given period of time     copyir.com    1 Check the Fusing Unit for correct installation (whether it is secured in position)     copyir.com 2 Check the Fusing Unit, PWB-M and PU1 for proper connection and correct or change as necessary     copyir.com 3 Change Fusing Unit     copyir.com 4 Change PWB-M     copyir.com 5 Change PU1     copyir.com
0501    Fusing Pressure Roller warm-up failure
• The Fusing Pressure Roller Thermistor/1 (TH2) fails to raise a given degree of temperature even after the lapse of a given period of time after the Fusing Pressure Heater Lamp (H3) is turned ON     copyir.com • The detected temperature of the Fusing Pressure Roller Thermistor/1 (TH2) is lower for a given level of degree than one of the Heating Roller Thermistor/1 (TH1) after the Front Door is opened or closed, the Main Power Switch is turned ON or TROUBLE RESET is implemented     copyir.com    1 Check the Fusing Unit for correct installation (whether it is secured in position)     copyir.com 2 Check the Fusing Unit, PWB-M and PU1 for proper connection and correct or change as necessary     copyir.com 3 Change Fusing Unit     copyir.com 4 Change PWB-M     copyir.com 5 Change PU1     copyir.com
0510    Abnormally low Heating Roller temperature
• The temperature of the Heating Roller Thermistor/1 (TH1) is lower than a given level of degree for 1 second or more uninterruptedly during Ready mode, Low Power mode or printing     copyir.com • The temperature of the Heating Roller Thermistor/2 (TH3) is lower than a given level of degree for 1 second or more uninterruptedly during Ready mode, Low Power mode or printing     copyir.com    1 Check the Fusing Unit for correct installation (whether it is secured in position)     copyir.com 2 Check the Fusing Unit, PWB-M and PU1 for proper connection and correct or change as necessary     copyir.com 3 Change Fusing Unit     copyir.com 4 Change PWB-M     copyir.com 5 Change PU1     copyir.com
0511    Abnormally low Fusing Pressure Roller temperature
• The temperature of the Fusing Pressure Roller Thermistor /1 (TH2) is lower than a given level of degree for 1 second or more uninterruptedly during Ready mode, Low Power mode or printing     copyir.com    1 Check the Fusing Unit for correct installation (whether it is secured in position)     copyir.com 2 Check the Fusing Unit, PWB-M and PU1 for proper connection and correct or change as necessary     copyir.com 3 Change Fusing Unit     copyir.com 4 Change PWB-M     copyir.com 5 Change PU1     copyir.com
0520    Abnormally high Heating Roller temperature
• The temperatures of the Heating Roller Thermistor/1 (TH1) and the Heating Roller Thermistor/2 (TH3) are higher than a given level of degree for 1 second or more uninterruptedly     copyir.com • The Heater Relay is OFF     copyir.com    1 Check the Fusing Unit for correct installation (whether it is secured in position)     copyir.com 2 Check the Fusing Unit, PWB-M and PU1 for proper connection and correct or change as necessary     copyir.com 3 Change Fusing Unit     copyir.com 4 Change PWB-M     copyir.com 5 Change PU1     copyir.com
0521    Abnormally high Fusing Pressure Roller temperature
• The temperature of the Fusing Pressure Roller Thermistor/1 (TH2) is higher than a given level of degree for 1 second or more uninterruptedly before the Heater temperature control starts     copyir.com • The temperature of the Fusing Pressure Roller Thermistor/1 (TH2) is higher than a given level of degree for 1 second or more uninterruptedly after the Heater temperature control starts     copyir.com    1 Check the Fusing Unit for correct installation (whether it is secured in position)     copyir.com 2 Check the Fusing Unit, PWB-M and PU1 for proper connection and correct or change as necessary     copyir.com 3 Change Fusing Unit     copyir.com 4 Change PWB-M     copyir.com 5 Change PU1     copyir.com
0900    Tray 4 Elevator failure
• The Lift-Up Sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started     copyir.com    1 Check the M3 connector for proper connection and correct as necessary     copyir.com 2 Check the connector of M3 for proper drive coupling and correct as necessary     copyir.com 3 PC7 I/O check, Sensor check PWB-Z PJ6Z PC-3 (ON) V-21 to 22     copyir.com 4 M3 operation check PWB-Z PJ4Z PC-4 to 5 Q-24     copyir.com 5 Change PWB-Z     copyir.com
0910    Tray 3 Elevator failure
• The Lift-Up Sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started     copyir.com    1 Check the M3 connector for proper connection and correct as necessary     copyir.com 2 Check the connector of M3 for proper drive coupling and correct as necessary     copyir.com 3 PC7 I/O check, Sensor check PWB-Z PJ6Z PC-3 (ON) V-21 to 22     copyir.com 4 M3 operation check PWB-Z PJ4Z PC-4 to 5 Q-24     copyir.com 5 Change PWB-Z     copyir.com
0950    Tray 5 Elevator failure
• The Lift-Up Sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started     copyir.com    1 Check the M3 connector for proper connection and correct as necessary     copyir.com 2 Check the connector of M3 for proper drive coupling and correct as necessary     copyir.com 3 PC7 I/O check, Sensor check PWB-Z PJ6Z PC-3 (ON) V-21 to 22     copyir.com 4 M3 operation check PWB-Z PJ4Z PC-4 to 5 Q-24     copyir.com 5 Change PWB-Z     copyir.com
0960    Manual Tray Rise Descent Error
• The Bypass Lift-Up Sensor is not blocked even when the Tray 2 Vertical Transport Motor has turned for a given number of pulses after the sequence to move the Paper Lifting Plate from the standby position to the feed position was started     copyir.com • The Bypass Lift-Up Sensor is not unblocked even when the Tray 2 Vertical Transport Motor has turned for a given number of pulses after the sequence to move the Paper Lifting Plate from the feed position to the standby position was started     copyir.com    1 Check the M2 connector for proper connection and correct as necessary     copyir.com 2 Check the connector of M2 for proper drive coupling and correct as necessary     copyir.com 3 PC14 I/O check, Sensor check PWB-M CNTRY1-10 (ON) C-10     copyir.com 4 M2 operation check PWB-Z PJ5Z PC-5 to 8 Q-22     copyir.com 5 Change PWB-Z     copyir.com
0F30    Abnormally low toner density detected Cyan TCR Sensor
• TC ratio in the developing machine, which is determined by Toner replenishing amount control mechanism, is 5 % or less for a given number of times consecutively     copyir.com    1 Perform image troubleshooting procedure if image density is low     copyir.com 2 Clean the TCR Sensor window on the underside of the Imaging Unit if dirty 3 M6, M7 operation check PWB-M CNDM2-10 to 13 (M6) PWB-M CNDM3-10 to 13 (M7) C-22 C-23     copyir.com 4 Reinstall Imaging Unit     copyir.com 5 Change Imaging Unit     copyir.com 6 Change PWB-M     copyir.com 7 Change PWB-P     copyir.com
0F31    Abnormally high toner density detected Cyan TCR Sensor
• TC ratio in the developing machine, which is determined by Toner replenishing amount control mechanism, is 12 % or more for a given number of times consecutively    1 Clean the TCR Sensor window on the underside of the Imaging Unit if dirty     copyir.com 2 Reinstall Imaging Unit     copyir.com 3 Change Imaging Unit     copyir.com 4 Change PWB-M     copyir.com 5 Change PWB-P     copyir.com
0F32    Abnormally low toner density detected Magenta TCR Sensor
• TC ratio in the developing machine, which is determined by Toner replenishing amount control mechanism, is 5 % or less for a given number of times consecutively     copyir.com    1 Perform image troubleshooting procedure if image density is low     copyir.com 2 Clean the TCR Sensor window on the underside of the Imaging Unit if dirty 3 M6, M7 operation check PWB-M CNDM2-10 to 13 (M6) PWB-M CNDM3-10 to 13 (M7) C-22 C-23     copyir.com 4 Reinstall Imaging Unit     copyir.com 5 Change Imaging Unit     copyir.com 6 Change PWB-M     copyir.com 7 Change PWB-P     copyir.com
0F33    Abnormally high toner density detected Magenta TCR Sensor
• TC ratio in the developing machine, which is determined by Toner replenishing amount control mechanism, is 12 % or more for a given number of times consecutively     copyir.com    1 Clean the TCR Sensor window on the underside of the Imaging Unit if dirty     copyir.com 2 Reinstall Imaging Unit     copyir.com 3 Change Imaging Unit     copyir.com 4 Change PWB-M     copyir.com 5 Change PWB-P     copyir.com
0F34    Abnormally low toner density detected Yellow TCR Sensor
• TC ratio in the developing machine, which is determined by Toner replenishing amount control mechanism, is 5 % or less for a given number of times consecutively     copyir.com    1 Perform image troubleshooting procedure if image density is low     copyir.com 2 Clean the TCR Sensor window on the underside of the Imaging Unit if dirty 3 M6, M7 operation check PWB-M CNDM2-10 to 13 (M6) PWB-M CNDM3-10 to 13 (M7) C-22 C-23     copyir.com 4 Reinstall Imaging Unit     copyir.com 5 Change Imaging Unit     copyir.com 6 Change PWB-M     copyir.com 7 Change PWB-P     copyir.com
0F35    Abnormally high toner density detected Yellow TCR Sensor
• TC ratio in the developing machine, which is determined by Toner replenishing amount control mechanism, is 12 % or more for a given number of times consecutively     copyir.com    1 Clean the TCR Sensor window on the underside of the Imaging Unit if dirty     copyir.com 2 Reinstall Imaging Unit     copyir.com 3 Change Imaging Unit     copyir.com 4 Change PWB-M     copyir.com 5 Change PWB-P     copyir.com
0F36    Abnormally low toner density detected Black TCR Sensor
• TC ratio in the developing machine, which is determined by Toner replenishing amount control mechanism, is 4 % or less for a given number of times consecutively     copyir.com    1 Perform image troubleshooting procedure if image density is low     copyir.com 2 Clean the TCR Sensor window on the underside of the Imaging Unit if dirty     copyir.com 3 M7 operation check PWB-M CNDM3-10 to 13 C-23     copyir.com 4 Reinstall Imaging Unit     copyir.com 5 Change Imaging Unit /K     copyir.com 6 Change PWB-M     copyir.com 7 Change PWB-P     copyir.com
0F37    Abnormally high toner density detected Black TCR Sensor
• TC ratio in the developing machine, which is determined by Toner replenishing amount control mechanism, is 12 % or more for a given number of times consecutively     copyir.com    1 Correct the TCR connection on the underside of the Imaging Unit if faulty     copyir.com 2 Reinstall Imaging Unit     copyir.com 3 Change Imaging Unit     copyir.com 4 Change PWB-M     copyir.com 5 Change PWB-P     copyir.com
0F3A    Cyan TCR Sensor adjustment failure
• TCR Sensor automatic adjustment does not function properly, failing to adjust to an appropriate value     copyir.com    1 Clean the TCR Sensor window on the underside of the Imaging Unit if dirty     copyir.com 2 M6, M7 operation check PWB-M CNDM2-10 to 13 (M6) PWB-M CNDM3-10 to 13 (M7) C-22 C-23     copyir.com 3 Reinstall Imaging Unit     copyir.com 4 Change Imaging Unit     copyir.com 5 Change PWB-M     copyir.com 6 Change PWB-P     copyir.com
0F3B    Magenta TCR Sensor adjustment failure
• TCR Sensor automatic adjustment does not function properly, failing to adjust to an appropriate value     copyir.com    1 Clean the TCR Sensor window on the underside of the Imaging Unit if dirty     copyir.com 2 M6, M7 operation check PWB-M CNDM2-10 to 13 (M6) PWB-M CNDM3-10 to 13 (M7) C-22 C-23     copyir.com 3 Reinstall Imaging Unit     copyir.com 4 Change Imaging Unit     copyir.com 5 Change PWB-M     copyir.com 6 Change PWB-P     copyir.com
0F3C    Yellow TCR Sensor adjustment failure
• TCR Sensor automatic adjustment does not function properly, failing to adjust to an appropriate value     copyir.com    1 Clean the TCR Sensor window on the underside of the Imaging Unit if dirty     copyir.com 2 M6, M7 operation check PWB-M CNDM2-10 to 13 (M6) PWB-M CNDM3-10 to 13 (M7) C-22 C-23     copyir.com 3 Reinstall Imaging Unit     copyir.com 4 Change Imaging Unit     copyir.com 5 Change PWB-M     copyir.com 6 Change PWB-P     copyir.com
0F3D    Black TCR Sensor adjustment failure
• TCR Sensor automatic adjustment does not function properly, failing to adjust to an appropriate value     copyir.com    1 Clean or correct each contact of the Imaging Unit if faulty     copyir.com 2 M7 operation check PWB-M CNDM3-10 to 13 C-23     copyir.com 3 Reinstall Imaging Unit /K     copyir.com 4 Change Imaging Unit /K     copyir.com 5 Change PWB-M     copyir.com 6 Change PWB-P     copyir.com
13B0    RTC failure
• When correct access to the RTC Board is failed during access     copyir.com    1 Check the connector for proper connection and correct as necessary     copyir.com 2 Change PWB-R     copyir.com 3 Change PWB-M     copyir.com
13C8    Transfer Unit New Article Release
• A new installation is not detected when a new Transfer Cleaner Unit (Image Transfer Belt Unit) is installed     copyir.com    1 Reinstall Unit     copyir.com 2 Change PWB-MD     copyir.com
13CA    Fusing Unit New Article Release
• A new installation is not detected when a new Fusing Unit is installed     copyir.com    1 Check the Fusing Unit for correct installation (whether it is secured in position)     copyir.com 2 Check the Fusing Unit, PWB-M for proper connection and correct or change as necessary     copyir.com 3 Reinstall Fusing Unit     copyir.com 4 Change Fusing Unit     copyir.com 5 Change PWB-M     copyir.com
13D0    Trouble related to Security
13D1    Cyan Imaging Unit EEPROM access error
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error     copyir.com • The error was found when reading out the counter value     copyir.com    1 Clean the connection between the Imaging Unit and the machine if dirty     copyir.com 2 Reinstall Imaging Unit     copyir.com 3 Change Imaging Unit     copyir.com 4 Change PWB-M     copyir.com
13D2    Magenta Imaging Unit EEPROM access error
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error     copyir.com • The error was found when reading out the counter value     copyir.com    1 Clean the connection between the Imaging Unit and the machine if dirty     copyir.com 2 Reinstall Imaging Unit     copyir.com 3 Change Imaging Unit     copyir.com 4 Change PWB-M     copyir.com
13D3    Yellow Imaging Unit EEPROM access error
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error     copyir.com • The error was found when reading out the counter value     copyir.com    1 Clean the connection between the Imaging Unit and the machine if dirty     copyir.com 2 Reinstall Imaging Unit     copyir.com 3 Change Imaging Unit     copyir.com 4 Change PWB-M     copyir.com
13D4    Black Imaging Unit EEPROM access error
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error     copyir.com • The error was found when reading out the counter value     copyir.com    1 Clean the connection between the Imaging Unit and the machine if dirty     copyir.com 2 Reinstall Imaging Unit     copyir.com 3 Change Imaging Unit     copyir.com 4 Change PWB-M     copyir.com
13D9    Cyan Toner Cartridge EEPROM access error
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error     copyir.com • The error was found when reading out the counter value     copyir.com    1 Clean the connection between the Toner Cartridge and the machine if dirty     copyir.com 2 Reinstall Toner Cartridge     copyir.com 3 Change Toner Cartridge     copyir.com 4 Change PWB-M     copyir.com
13DA    Magenta Toner Cartridge EEPROM access error
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error     copyir.com • The error was found when reading out the counter value     copyir.com    1 Clean the connection between the Toner Cartridge and the machine if dirty     copyir.com 2 Reinstall Toner Cartridge     copyir.com 3 Change Toner Cartridge     copyir.com 4 Change PWB-M     copyir.com
13DB    Yellow Toner Cartridge EEPROM access error
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error     copyir.com • The error was found when reading out the counter value     copyir.com    1 Clean the connection between the Toner Cartridge and the machine if dirty     copyir.com 2 Reinstall Toner Cartridge     copyir.com 3 Change Toner Cartridge     copyir.com 4 Change PWB-M     copyir.com
13DC    Black Toner Cartridge EEPROM access error
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error     copyir.com • The error was found when reading out the counter value     copyir.com    1 Clean the connection between the Toner Cartridge and the machine if dirty     copyir.com 2 Reinstall Toner Cartridge     copyir.com 3 Change Toner Cartridge     copyir.com 4 Change PWB-M     copyir.com
13E2    Flash ROM write error
• Flash ROM writing is found faulty during a check     copyir.com    1 Change PWB-M     copyir.com
3000    Main Motor’s failure to turn
• The Motor Lock signal remains HIGH for a predetermined continuous period of time while the Motor is turning     copyir.com    1 Check the M1 connector for proper connection and correct as necessary     copyir.com 2 Check M1 for proper drive coupling and correct as necessary     copyir.com 3 Check the PWB-M connector for proper connection and correct as necessary     copyir.com 4 M1 operation check PWB-M CNDM1-5 (REM) PWB-M CNDM1-8 (LOCK) K to L-2     copyir.com 5 Change PWB-M     copyir.com 6 Change PU1     copyir.com
C002    RAM (standard) error at startup
• RAM error at Standard Memory is detected during printer start-up     copyir.com    1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer     copyir.com) 2 Check connection state of the extension memory and correct as necessary     copyir.com 3 Check the PWB-P connector for proper connection and correct as necessary     copyir.com 4 Change the extension memory     copyir.com 5 Change PWB-P     copyir.com
C003    RAM (option) error at startup
• RAM error at Extension Memory is detected during printer start-up     copyir.com    1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer     copyir.com) 2 Check connection state of the extension memory and correct as necessary     copyir.com 3 Check the PWB-P connector for proper connection and correct as necessary     copyir.com 4 Change the extension memory     copyir.com 5 Change PWB-P     copyir.com
C013    MAC address error at startup (MAC address is invalid)
• Invalid Mac address is detected during printer start-up     copyir.com    1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer     copyir.com) 2 Check the PWB-P connector for proper connection and correct as necessary     copyir.com 3 Change PWB-P     copyir.com
C015    Boot ROM error at startup
• Boot ROM error is detected during printer start-up     copyir.com    1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer     copyir.com) 2 Check the PWB-P connector for proper connection and correct as necessary     copyir.com 3 Change PWB-P     copyir.com
C022    NVRAM access error
• Correct access to NVRAM is failed during the printer starting     copyir.com    1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer     copyir.com) 2 Check the PWB-P connector for proper connection and correct as necessary     copyir.com 3 Change PWB-P     copyir.com
C025    Controller ROM error
• Lead error of destination setting file is detected during the printer starting     copyir.com
C026    Controller ROM error
• Flash ROM access error is detected during the printer starting     copyir.com    1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer     copyir.com) 2 Check the PWB-P connector for proper connection and correct as necessary     copyir.com 3 If this error message is displayed after update of firmware, conduct the firmware update procedures again     copyir.com 4 Change PWB-P     copyir.com
C027    Controller ROM error
• Final check sum error is detected during the printer starting     copyir.com    1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer     copyir.com) 2 Check the PWB-P connector for proper connection and correct as necessary     copyir.com 3 If this error message is displayed after update of firmware, conduct the firmware update procedures again     copyir.com 4 Change PWB-P     copyir.com
C050    HDD access error
• When correct access to the Hard Disk Kit is failed during access     copyir.com    1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer     copyir.com) 2 Check the HDD connector for proper connection and correct as necessary     copyir.com 3 Check the PWB-P connector for proper connection and correct as necessary     copyir.com 4 Change HDD     copyir.com 5 Change PWB-P     copyir.com
C051    HDD full error
• Range for user space is full during access to the Hard Disk Kit     copyir.com    1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer     copyir.com) 2 Check the HDD connector for proper connection and correct as necessary     copyir.com 3 Change HDD     copyir.com
C052    Compact Flash access error
• When correct access to the Compact Flash is failed during access     copyir.com    1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer     copyir.com) 2 Check the Compact Flash for proper connection and correct as necessary     copyir.com 3 Check the PWB-P connector for proper connection and correct as necessary     copyir.com 4 Change Compact Flash     copyir.com 5 Change PWB-P     copyir.com
C053    Compact Flash full error
• Range for user space is full during access to the Compact Flash     copyir.com    1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer     copyir.com) 2 Check the Compact Flash for proper connection and correct as necessary     copyir.com 3 Change Compact Flash     copyir.com
C054    Compact Flash uninstallation
• Compact Flash is not installed while accessing to the Compact Flash     copyir.com    1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer     copyir.com) 2 Check the Compact Flash for proper connection and correct as necessary     copyir.com 3 Check the PWB-P connector for proper connection and correct as necessary     copyir.com 4 Change Compact Flash     copyir.com 5 Change PWB-P     copyir.com
C060    Firmware update error
• Firmware update fails to complete correctly during update     copyir.com    1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer     copyir.com) 2 Check the cable that has been used for update of the firmware for proper connection and correct as necessary     copyir.com 3 Update the firmware again     copyir.com 4 Check the PWB-P connector for proper connection and correct as necessary     copyir.com 5 Change PWB-P     copyir.com
C061    Hold job error/No Duplex unit
• The Duplex Option is not installed, but it is required for printing the job held in the HDD     copyir.com    1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer     copyir.com) 2 Return to the same state as the device configuration when job was held     copyir.com 3 Check the options that are mounted on the printer for proper connection and correct as necessary     copyir.com 4 Check the PWB-M connector for proper connection and correct as necessary     copyir.com 5 Delete the job hold in [PROOF/PRINT MENU]     copyir.com
C062    Hold job error/No Tray 3
• Tray 3 is not set when the tray 3 is required for printing of the job hold in HDD     copyir.com    1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer     copyir.com) 2 Return to the same state as the device configuration when job was held     copyir.com 3 Check the options that are mounted on the printer for proper connection and correct as necessary     copyir.com 4 Check the PWB-M connector for proper connection and correct as necessary     copyir.com 5 Delete the job hold in [PROOF/PRINT MENU]     copyir.com
C063    Hold job error/No Tray 4
• Tray 4 is not set when the tray 4 is required for printing of the job hold in HDD     copyir.com    1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer     copyir.com) 2 Return to the same state as the device configuration when job was held     copyir.com 3 Check the options that are mounted on the printer for proper connection and correct as necessary     copyir.com 4 Check the PWB-M connector for proper connection and correct as necessary     copyir.com 5 Delete the job hold in [PROOF/PRINT MENU]     copyir.com
C064    Hold job error/No Memory
• Expansion memory is not set when the expansion memory is required for printing of the job hold in HDD     copyir.com    1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer     copyir.com) 2 Return to the same state as the device configuration when job was held     copyir.com 3 Check the options that are mounted on the printer for proper connection and correct as necessary     copyir.com 4 Check the PWB-M connector for proper connection and correct as necessary     copyir.com 5 Delete the job hold in [PROOF/PRINT MENU]     copyir.com
C065    Hold job error/No Tray 5
• Tray 5 is not set when the tray 5 is required for printing of the job hold in HDD     copyir.com    1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer     copyir.com) 2 Return to the same state as the device configuration when job was held     copyir.com 3 Check the options that are mounted on the printer for proper connection and correct as necessary     copyir.com 4 Check the PWB-M connector for proper connection and correct as necessary     copyir.com 5 Delete the job hold in [PROOF/PRINT MENU]     copyir.com
FFFF    Interface Communication error
• Correct communication is failed when receiving/sending the command between PWB-A and PWB-P     copyir.com    1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer     copyir.com) 2 Check the PWB-P connector for proper connection and correct as necessary 3 Check the PWB-M connector for proper connection and correct as necessary     copyir.com 4 Change PWB-M     copyir.com
C064    Hold job error/No Memory
• Expansion memory is not set when the expansion memory is required for printing of the job hold in HDD     copyir.com    1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer     copyir.com) 2 Return to the same state as the device configuration when job was held     copyir.com 3 Check the options that are mounted on the printer for proper connection and correct as necessary     copyir.com 4 Check the PWB-M connector for proper connection and correct as necessary     copyir.com 5 Delete the job hold in [PROOF/PRINT MENU]     copyir.com
C065    Hold job error/No Tray 5
• Tray 5 is not set when the tray 5 is required for printing of the job hold in HDD     copyir.com    1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer     copyir.com) 2 Return to the same state as the device configuration when job was held     copyir.com 3 Check the options that are mounted on the printer for proper connection and correct as necessary     copyir.com 4 Check the PWB-M connector for proper connection and correct as necessary     copyir.com 5 Delete the job hold in [PROOF/PRINT MENU]     copyir.com
FFFF    Interface Communication error
• Correct communication is failed when receiving/sending the command between PWB-A and PWB-P     copyir.com    1 Turn OFF the Power Switch of the printer and turn it ON again (Restart of the printer     copyir.com) 2 Check the PWB-P connector for proper connection and correct as necessary 3 Check the PWB-M connector for proper connection and correct as necessary     copyir.com 4 Change PWB-M     copyir.com