C05    Communication problem between main boards
C06    Battery/memory problem
C21    Main motor drive
C22    Duplex motor drive
C23    Paper feed motor drive
C24    Duplex motor drive
C25    Paper feed motor drive
C31    Open exposure lamp     copir.com
C32    Exposure lamp stays on
C35    Scan motor or scan motor board or fuser     copir.com
C37    Scan sensor not actuated or not deactuated at proper time
C41    Lens motor     copir.com
C51    Charge corona
C52    Transfer/separator corona       copir.com
C53    Bias is less then 100 volts
C55    Drum surface voltage is too high     copir.com
C56    Drum surface voltage is too low
C61    Fuser lamp closest to exit end stays off
C62    Fuser lamp closest to drum stays off        copir.com
C63    Fuser lamp(s) stays on
C65    High fuser temperature
C66    Open fuser thermistor        copir.com
C71    Blank lamp problem
C72    Drum thermistor shorted
C73    Drum thermistor open     copir.com
C74    High DV unit temperature or shorted DV thermistor
C75    Open DV thermistor      copir.com