کونیکا مینولتا Konica-Minolta bizhub C652
C0104 Tray 3/4 feeder transportation motor failure to turn
• The lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary copyir.com
C0105 Tray 3/4 feeder transportation motor turning at abnormal timing
• The lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary copyir.com
C0202 Tray 1 feeder up/down abnormality
• The tray 1 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started copyir.com
C0204 Tray 2 feeder up/down abnormality
• The tray 2 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started copyir.com
C0206 Tray 3 feeder up/down abnormality
• The tray 3 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started copyir.com
C0208 Tray 4 feeder up/down abnormality
• The tray 4 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started copyir.com
C0216 LCT up/down abnormality
• The Upper limit sensor (PS2) is not blocked even after the set period of time has elapsed after the paper lift-up operation began copyir.com
C0301 Suction fan motor’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary copyir.com
C0351 Paper cooling fan trouble
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary copyir.com
C1003 PK communication error <When FS-526+PK-516 is installed>
• When a communication error is detected between the FS control board (FSCB) and the punch control board (PKDB) copyir.com
C1004 FNS communication error
• When the FS control board (FSCB) is receiving data, a communication error is detected copyir.com
C1005 ZU communication error
• When the ZU control board (ZUCB) is receiving data, a communication error is detected copyir.com
C1081 SD communication error
<When FS-527+SD-509 is installed> • When a communication error is detected between the FS control board (FSCB) and the SD drive board (SDDB) copyir.com
C1102 Main tray Up/Down motor malfunction
<When FS-526 is installed> • The main tray top surface sensor (PS4) is turned neither ON nor OFF even after the set period of time has elapsed while the main tray lift motor (M5) is energized copyir.com • The staple paper exit top surface sensor (PS7) is turned neither ON nor OFF even after the set period of time has elapsed while the main tray lift motor (M5) is energized copyir.com
C1103 Side-staple front adjust drive motor malfunction
<When FS-526 is installed> • The 2 staples alignment motor home sensor/F (PS17) is not turned ON even after the set period of time has elapsed while the Alignment plate motor/F (M11) is energized copyir.com
C1104 Paper exit roller drive motor malfunction
<When FS-526 is installed> • The exit roller motor (M4) lock signal remains set to H for a set period of time while the exit roller motor (M4) is turning copyir.com
C1105 Paper exit auxiliary roller motor malfunction
<When FS-526 is installed> • The paper output roller home sensor (PS10) is turned neither ON nor OFF even after the set period of time has elapsed after the paper output roller motor (M6) is turned ON copyir.com
C1106 Side-staple stapler drive malfunction
<When FS-526 is installed> • The stapler position sensor/1/2/3/4 (PS50/ PS/51/PS52/PS53) is turned neither ON nor OFF even after the set period of time has elapsed after the 2 staples stapler movement motor (M13) is turned ON copyir.com
C1109 Side-staple stapler motor drive malfunction
<When FS-526 is installed>• The home sensor in the staple unit does not turn ON even after the set period of time has elapsed after the side-staple 2 staples stapler motor (M14) turned ON copyir.com
C1110 Center-staple head roller motor malfunction
• The stapler home sensor (PS33) is turned neither ON nor OFF even after the set period of time has elapsed after the staple motor (M24) is turned ON copyir.com
C1112 Center-staple clinch roller motor malfunction
<When FS-526+SD-508 is installed> • The stapler home sensor (PS33) is not turned ON even after the set period of time has elapsed while the clincher motor (M25) is energized copyir.com
C1113 Center-staple lead edge stopper motor malfunction
<When FS-526+SD-508 is installed> • The leading edge stopper home sensor (PS32) is turned neither ON nor OFF even after the set period of time has elapsed after the leading edge stopper motor (M22) is turned ON copyir.com <When FS-527+SD-509 is installed> • The leading edge stopper home sensor (PS45) is turned neither ON nor OFF even after the set period of time has elapsed after the leading edge stopper motor (M20) is turned ON copyir.com
C1114 Center-staple front adjust drive motor malfunction
<When FS-526+SD-508 is installed> • The center staple alignment motor home sensor/F (PS30) is turned neither ON nor OFF even after the set period of time has elapsed after the center staple alignment motor /F (M20) is turned ON copyir.com <When FS-527+SD-509 is installed> • The center staple alignment home sensor/F (PS42) is turned neither ON nor OFF even after the set period of time has elapsed after the center staple alignment motor/F (M24) is turned ON copyir.com
C1115 Center-staple knife drive motor malfunction
<When FS-526+SD-508 is installed> • The center fold knife home sensor (PS34) is not turned ON even after the set period of time has elapsed while the center fold knife motor (M32) is energized copyir.com <When FS-527+SD-509 is installed> • The center fold plate home sensor (PS47) is turned neither ON nor OFF even after the set period of time has elapsed after the center fold plate motor (M26) is turned ON copyir.com
C1116 Center-staple transfer motor malfunction
<When FS-526+SD-508 is installed> • The transport motor (M33) does not reach the specified speed even after the set period of time has elapsed after it starts to operate copyir.com <When FS-527+SD-509 is installed> • The center fold roller motor (M25) does not reach the specified speed even after the set period of time has elapsed after it starts to operate copyir.com
C1124 Sheet feeder up/down drive failure (lower)
<When FS-526+PI-505 is installed> • The tray upper limit sensor /Lw (PS209) or tray lower limit sensor /Lw (PS210) are not turned ON even after the set period of time has elapsed after the tray lift motor /Lw (M202) is energized copyir.com
C1125 Sheet feeder up/down drive failure (upper)
<When FS-526+PI-505 is installed> • The tray lower limit sensor /Up (PS205) or tray upper limit sensor /Up (PS204) are not turned ON even after the set period of time has elapsed after the tray lift motor /Up (M201) is energized copyir.com
C1127 Punch shift motor drive malfunction
<When FS-526+PK-516 is installed> • The PK punch home sensor (PS301) is not turned ON even after the set period of time has elapsed while the punch drive motor (M301) is energized copyir.com
C1130 1st stopper motor drive malfunction
<When FS-526+ZU-606 is installed> • The 1st folding stopper home sensor (PS603) is not turned ON even after the set period of time has elapsed after the 1st stopper motor (M602) starts searching home position copyir.com
C1131 2nd stopper motor drive malfunction
<When FS-526+ZU-606 is installed> • The 2nd stopper home sensor (PS604) is not turned ON even after the set period of time has elapsed after the 2nd stopper motor (M603) starts searching home position copyir.com
C1132 Output OP punch driving motor malfunction
<When FS-526+PK-516 is installed> • The PK punch oscillating home sensor (PS303) is turned neither ON nor OFF even after the set period of time has elapsed while the punch oscillating motor (M302) is energized copyir.com
C1133 Punch shift motor drive malfunction <When FS-526+ZU-606 is installed>
•The punch shift home sensor (PS605) is not turned ON, or is not turned OFF after it is turned ON, even after the set period of time has elapsed after the punch shift motor (M605) starts searching its home position copyir.com
C1134 Main motor cooling fan drive malfunction
<When FS-526+ZU-606 is installed> •Even after the set period of time has elapsed after the main motor cooling fan (FM601) is turned ON, the FM601 EM signal is faulty and the fan is turned OFF; the signal is faulty after each of the following three trials copyir.com
C1135 Punch motor drive malfunction
<When FS-526+ZU-606 is installed> •The punch motor (M604) is not turned OFF even after the set period of time has elapsed after it is turned ON copyir.com
C1136 Punch switchover motor drive malfunction
<When FS-526+ZU-606 is installed> •The punch switchover switch (MS601) is not turned OFF from the ON position, or not turned ON from the OFF position, even after the set period of time has elapsed after the punch switchover motor (M608) is turned ON copyir.com
C1140 Side-staple rear adjust drive motor malfunction
<When FS-526 is installed> • The 2 staples alignment motor home sensor/R (PS18) is not turned ON even after the set period of time has elapsed while the alignment plate motor/R (M12) is energized copyir.com
C1141 Side-staple paddle roller motor malfunction
<When FS-526 is installed> • The paddle motor (M16) lock signal remains set to H for a set period of time while the paddle motor (M16) is turning copyir.com
C1142 Side-staple trailing paddle up-down motor malfunction
<When FS-526 is installed> • The trail edge paddle home sensor (PS20) is turned neither ON nor OFF even after the set period of time has elapsed after the trail edge paddle motor (M15) is turned ON copyir.com
C1143 Side-staple rewinding paddle up-down motor malfunction
<When FS-526 is installed> •The rewind paddle home sensor (PS16) is turned neither ON nor OFF even after the set period of time has elapsed after the rewind paddle motor (M18) is turned ON copyir.com
C1144 Spare stacker board drive motor malfunction
<When FS-526 is installed> • The stacker plate home sensor (PS11) is turned neither ON nor OFF even after the set period of time has elapsed while the stacker plate motor (M17) is energized copyir.com
C1145 End stopper drive motor malfunction
<When FS-526 is installed> • The 2 staples trail edge stopper home sensor (PS22) is turned neither ON nor OFF even after the set period of time has elapsed after the 2 staples trail edge stopper motor (M19) is turned ON copyir.com • The 2 staples trail edge stopper standby sensor/1 (PS23) is turned neither ON nor OFF even after the set period of time has elapsed after the 2 staples trail edge stopper motor (M19) is turned ON copyir.com • The 2 staples trail edge stopper standby sensor/2 (PS42) is turned neither ON nor OFF even after the set period of time has elapsed after the 2 staples trail edge stopper motor (M19) is turned ON copyir.com
C1150 Center-staple rear adjust drive motor malfunction <When FS-526+SD-508 is installed>
• The center staple alignment motor home sensor/R (PS31) is turned neither ON nor OFF even after the set period of time has elapsed after the center staple alignment motor /R (M21) is turned ON copyir.com <When FS-527+SD-509 is installed> • The center staple alignment home sensor/R (PS41) is turned neither ON nor OFF even after the set period of time has elapsed after the center staple alignment motor/R (M23) is turned ON copyir.com
C1151 Center-staple stapler drive motor malfunction
<When FS-526+SD-508 is installed> • The stapler home sensor (PS33) is turned neither ON nor OFF even after the set period of time has elapsed after the center staple motor (M23) is turned ON copyir.com
C1152 Center-staple paper exit motor malfunction
<When FS-526+SD-508 is installed> • The exit motor (M34) lock signal remains set to H for a set period of time while the exit motor (M34) is turning copyir.com
C1153 Center-staple paddle up-down motor malfunction
<When FS-526+SD-508 is installed> • The paddle home sensor/C (PS37) is turned neither ON nor OFF even after the set period of time has elapsed after the center staple paddle lift motor/C (M26) is turned ON copyir.com
C1156 Center-staple paddle roller motor malfunction (trailing edge)
<When FS-526+SD-508 is installed> • The center staple paddle/T (M29) lock signal remains set to L for a set period of time while the center staple paddle/T (M29) is turning copyir.com <When FS-527+SD-509 is installed> • Even after the set period of time has elapsed after the upper paddle motor (M21) starts running, a change of motor lock signal is not detected and neither the paper detection sensor/1 (PS43) nor the paper detection sensor/2 (PS44) is turned ON copyir.com
C1157 Center-staple paddle roller motor malfunction (middle)
<When FS-526+SD-508 is installed> • The center staple paddle/C (M30) lock signal remains set to L for a set period of time while the center staple paddle/C (M30) is turning copyir.com
C1158 Center-staple paddle roller motor malfunction (leading edge)
<When FS-527+SD-509 is installed>• Even after the set period of time has elapsed after the lower paddle motor (M22) starts running, a change of motor lock signal is not detected and neither the paper detection sensor/1 (PS43) nor the paper detection sensor/2 (PS44) is turned ON copyir.com
C1182 Shift motor drive malfunction
<When JS-504 is installed> • The shift home sensor (PS6) is not blocked after the set period of time has elapsed after the shift motor (M2) is turned ON (start of moving to the home position copyir.com) • The shift home sensor (PS6) is not unblocked twice in a row after the set period of time has elapsed after the shift motor (M2) is turned ON (start of moving to the shift position copyir.com) <When FS-527 is installed> • When moving to the front (home) position: The tray 1 shift home sensor (PS25) is not turned ON even after the set period of time has elapsed after the tray 1 shift motor (M16) is turned ON copyir.com • When moving to the rear (shift) position: The tray 1 shift home sensor (PS25) is not turned OFF even after the set period of time has elapsed after the tray 1 shift motor (M16) is turned ON copyir.com
C1190 Alignment plate motor drive malfunction
<When FS-527 is installed> • The alignment plate home sensor (PS17) is turned neither ON nor OFF even after the set period of time has elapsed after the alignment plate motor (M13) is turned ON copyir.com
C1194 Leading edge stopper motor drive malfunction
<When FS-527 is installed> • The leading edge stopper home sensor (PS20) is turned neither ON nor OFF even after the set period of time has elapsed after the leading edge stopper motor (M14) is turned ON copyir.com
C11A1 Tray 2 exit roller pressure/ retraction malfunction
<When FS-527 is installed> • The exit roller pressure sensor (PS12) is turned neither ON nor OFF even after the set period of time has elapsed after the exit roller retraction motor (M9) is turned ON copyir.com
C11A2 Accommodation roller pressure/ retraction malfunction
<When FS-527 is installed> • The accommodation roller pressure sensor (PS13) is turned neither ON nor OFF even after the set period of time has elapsed after the accommodation roller retraction motor (M10) is turned ON copyir.com
C11A7 Tray 3 exit roller pressure/ retraction malfunction
<When JS-603 is installed> • The exit roller pressure sensor (PS12) is turned neither ON nor OFF even after the set period of time has elapsed after the exit roller retraction motor (M9) is turned ON copyir.com
C11B0 Stapler movement drive malfunction
<When FS-527 is installed> •During home position search, neither the stapler home sensor/1 (PS18) nor the stapler home sensor/2 (PS19) is turned ON or OFF even after the set period of time has elapsed after the stapler movement motor (M11) is turned ON copyir.com
C11B2 Staple drive malfunction
<When FS-527 is installed> • The stapler home sensor is turned neither ON nor OFF even after the set period of time has elapsed after the stapler motor is turned ON copyir.com
C11B5 Saddle stapler drive malfunction
C11C0 Punch motor drive malfunction
<When FS-527+PK-517 is installed> •The punch home sensor/1 (PS100) is not turned ON even after the set period of time has elapsed while the punch motor/1 (M100) is energized copyir.com
C11E0 Duplex path switching motor drive malfunction
<When FS-527 is installed> •The duplex path switching sensor (PS3) is turned neither ON nor OFF even after the set period of time has elapsed after the duplex path switching motor (M2) is turned ON copyir.com
C11E0 Finisher route change malfunction
<When JS-504 is installed> •The route change home sensor (PS4) is not blocked after the set period of time has elapsed after the route change motor (M3) is turned ON (start of shifting to the lower tray route copyir.com) •The route change home sensor (PS4) is not unblocked after the set period of time has elapsed after the route change motor (M3) is turned ON (start of shifting to the upper tray route copyir.com)
C11E1 Upper lower path switching motor drive malfunction
<When FS-527 is installed> •The upper lower path switching sensor (PS26) is turned neither ON nor OFF even after the set period of time has elapsed after the upper lower path switching motor (M6) is turned ON copyir.com
C11E2 Tray1 path switching motor drive malfunction
<When FS-527 is installed> • The tray1 path switching home sensor (PS7) is turned neither ON nor OFF even after the set period of time has elapsed after the tray1 path switching motor (M8) is turned ON copyir.com
C2101 PC charge cleaning malfunction
•During backward movement of the cleaner, the charging cleaner home sensor is not blocked after a predetermined period of time has elapsed copyir.com
C2151 Secondary transfer roller pressure welding alienation
• The pressure welding alienation sensor doesn’t turn OFF (retracting) even after the lapse of a given period of time after the 2nd image transfer pressure retraction motor has started rotating during the 2nd image transfer roller is retracting copyir.com • The pressure welding alienation sensor doesn’t turn ON (pressuring) even after the lapse of a given period of time after the 2nd image transfer pressure retraction motor has started rotating during the 2nd image transfer roller is pressuring copyir.com
C2152 Transfer belt pressure welding alienation
• At the completion of transfer belt pressure/ retraction operations, the pressure welding alienation sensor/K or the pressure welding alienation sensor/color is not in the status corresponding to each of the transfer belt pressure/retraction operations copyir.com See the table below copyir.com •Even after a predetermined period of time has elapsed since the transfer belt starts pressure/retraction operation, the pressure welding alienation sensor/K or the pressure welding alienation sensor/color is not in the status corresponding to each of the transfer belt pressure/retraction operations copyir.com See the table below copyir.com Operation Position Sensor status (K: Color) • Color and K retraction – K pressure • Color and K pressure – K K pressure ON (not blocked) :OFF (blocked) pressure • Color and K retraction – Color and K pressure • K pressure – Color and K pressure Color and K pressure ON (not blocked):ON (not blocked) • K pressure – Color and K retraction • Color and K pressure – Color and K Color and K retraction OFF (blocked): OFF (blocked) retraction
C2160 PC charge (C) malfunction
• When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time copyir.com In this case, C2164 is displayed at the first detection and then after the trouble is reset, a leak IU identification process is executed copyir.com Then the trouble code corresponding to the IU color is displayed copyir.com
C2161 PC charge (M) malfunction
C2162 PC charge (Y) malfunction
C2163 PC charge (K) malfunction
C2164 PC charge malfunction
C2204 Waste toner agitating motor’s failure to turn
•The waste toner agitating motor lock sensor continues to be blocked or unblocked for a predetermined period of time when the motor is turning copyir.com
C2253 Color PC drum motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning copyir.com
C2254 Color PC drum motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary copyir.com
C2255 Color developing motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning copyir.com
C2256 Color developing motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary copyir.com
C2257 Cleaner motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning copyir.com
C2258 Cleaner motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary copyir.com
C2259 K developing motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning copyir.com
C225A K developing motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary copyir.com
C225B K PC drum motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning copyir.com
C225C K PC drum motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary copyir.com
C2350 Toner suction fan motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning copyir.com
C2353 IU cooling fan motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning copyir.com
C2354 Rear side cooling fan motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning copyir.com
C2551 Abnormally low toner density detected cyan TCR sensor
• When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper copyir.com
C2552 Abnormally high toner density detected cyan TCR sensor
• TC ratio in the developing unit which is determined by Toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively copyir.com
C2553 Abnormally low toner density detected magenta TCR sensor
• When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper copyir.com
C2554 Abnormally high toner density detected magenta TCR sensor
• TC ratio in the developing unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively copyir.com
C2555 Abnormally low toner density detected yellow TCR sensor
• When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper copyir.com
C2556 Abnormally high toner density detected yellow TCR sensor
• TC ratio in the developing unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively copyir.com
C2557 Abnormally low toner density detected black TCR sensor
• When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper copyir.com
C2558 Abnormally high toner density detected black TCR sensor
• TC ratio in the developing unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively copyir.com
C2559 Cyan TCR sensor adjustment failure
• TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value copyir.com
C255A Magenta TCR sensor adjustment failure
C255B Yellow TCR sensor adjustment failure
C255C Black TCR sensor adjustment failure
C2561 Cyan TCR sensor failure
• Alarm signals for a TCR sensor are detected more than the predetermined number of times copyir.com This detection is used for detecting disconnection of TCR sensor connector copyir.com
C2562 Magenta TCR sensor failure
C2563 Yellow TCR sensor failure
C2564 Black TCR sensor failure
C2650 Main backup media access error
• Contact the responsible people of KMBT before taking some countermeasures copyir.com
C2651 EEPROM access error (IU C)
•The re-written data, which has been read out, checked and founded as error, is read out again and found as error copyir.com • The error was found when reading out the counter value copyir.com
C2652 EEPROM access error (IU M)
C2653 EEPROM access error (IU Y)
C2654 EEPROM access error (DC K)
C2A14 Drum unit/K new release failure
•The status with the new unit is not cleared after the new drum unit/K is set copyir.com
C2A21 Toner cartridge/C new release failure
•The status with the new cartridge is not cleared after the new toner cartridge is set
C2A22 Toner cartridge/M new release failure
C2A23 Toner cartridge/Y new release failure
C2A24 Toner cartridge/K new release failure
C3101 Fusing roller separation failure
• With the fusing roller being retracted, the pulse of the encoder sensor does not change even after the specified period of time has passed after the fusing pressure retraction motor started rotating copyir.com • With the fusing roller being pressed, the encoder pulse sensor does not change even after the specified period of time has passed after the fusing pressure retraction motor started rotating copyir.com • With the pressure roller being pressed, the pressure home sensor did not turn ON (pressed) even after the fusing retraction position sensor counted up the specified number of pulse after the fusing pressure retraction motor started rotating copyir.com
C3102 Fusing roller failure to turn
• When the IH power supply is turned ON, pulse signals are not input either of the heating roller rotation sensor within a predetermined period of time copyir.com
C3201 Fusing motor failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary copyir.com
C3202 Fusing motor turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary copyir.com
C3303 Fusing cooling fan motor/ 1 failure to turn
• The fan motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary copyir.com
C3304 Fusing cooling fan motor/ 2 failure to turn
• The fan motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary copyir.com
C3305 Fusing cooling fan motor/ 3 failure to turn
• The fan motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary copyir.com
C3424 Fusing heaters trouble (soaking side)
• After warm-up operation starts, the soaking roller thermistor does not detect a temperature as high as a predetermined one though a predetermined period of time has elapsed copyir.com
C3425 Fusing heaters trouble (NC sensor)
• After warm-up operation starts, the heating roller temperature sensor/1 does not detect a temperature as high as a predetermined one though a predetermined period of time has elapsed copyir.com
C3721 Fusing abnormally high temperature detection (Center of the heating roller)
• The heating roller temperature sensor/2 continues to detect a temperature higher than a predetermined one for a predetermined period of time copyir.com • The signal is turned ON to activate the hard ratchet in the middle of the heating side copyir.com
C3722 Fusing abnormally high temperature detection (Edge of the heating roller)
• The heating roller temperature sensor/3 continues to detect a temperature higher than a predetermined one for a predetermined period of time copyir.com • The signal is turned ON to activate the hard ratchet at the edges of the heating side copyir.com
C3724 Fusing abnormally high temperature detection (soaking side)
• The soaking roller thermistor/1 continues to detect a temperature higher than a predetermined one for a predetermined period of time copyir.com • The signal is turned ON to activate the hard ratchet on the soaking side copyir.com
C3725 Fusing abnormally high temperature detection (NS sensor)
• The heating roller temperature sensor/1 continues to detect a temperature higher than a predetermined one for a predetermined period of time copyir.com
C3822 Fusing abnormally low temperature detection (Edge of the heating roller)
• The heating roller thermistor/2 continues to detect a temperature lower than a predetermined one for a predetermined period of time copyir.com
C3824 Fusing abnormally low temperature detection (soaking side)
• The soaking roller thermistor/1 continues to detect a temperature lower than a predetermined one for a predetermined period of time copyir.com
C3825 Fusing abnormally low temperature detection (NC sensor)
• The heating roller temperature sensor/1 continues to detect a temperature lower than a predetermined one for a predetermined period of time copyir.com
C3921 Fusing sensor wire breaks detection (Center of the heating roller)
• At the warm-up stage, the heating roller temperature sensor/2 voltage does not decrease by predetermined steps (temperature rise) within a predetermined time copyir.com
C3922 Fusing sensor wire breaks detection (Edge of the heating roller)
• At the warm-up stage, the heating roller temperature sensor/3 voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time copyir.com
C3924 Fusing sensor wire breaks detection (soaking side)
• At the warm-up stage, the soaking roller thermistor/1 voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time copyir.com
C3925 Fusing sensor wire breaks detection (NC sensor)
• At the warm-up stage, the heating roller temperature sensor/1 voltage does not increase by predetermined steps (temperature rise) within a predetermined period of time copyir.com
C392A Fusing sensor contamination (NC sensor)
• While checking the contamination on the heating roller temperature sensor/1, detected temperature of the heating roller thermistor/1 exceeded the detected temperature of the heating roller temperature sensor/1 for over the predetermined value for the predetermined period of time copyir.com
C3B02 IH malfunction (CPU)
• A failure in communication with the fusing CPU continues for a predetermined period of time copyir.com
C3B03 IH malfunction (monitor)
• Though the IH heater is ON, this status cannot be detected mechanically copyir.com (IH heater operation failure) •Though the IH heater is OFF, mechanically, the ON status is detected copyir.com (Malfunction of IH heater operation)
C3B05 IH temperature sensor defect
• While the IH heater was on, IH temperature sensor was disconnected for more than the predetermined period of time copyir.com • While the IH heater was on, short circuit on IH temperature sensor continued for more than the predetermined period of time copyir.com • While the IH heater was on, temperature change occurred within the predetermined period of time with over the predetermined range, and they continued for more than the predetermined period of time copyir.com • While the IH heater was on, temperature around the heat radiator stayed high for over the predetermined period of time copyir.com
C3B06 IH surge error
• While the IH heater was on, IH stopped due to input voltage which exceeded that of surge detection voltage, and the surge detection voltage continued for more than the predetermined period of time copyir.com
C3B07 IH input power error
• While the IH heater was on, input power stayed at the high voltage power detection value or over for more than the predetermined period of time copyir.com • While the IH heater was on, input power was at the low power detection value or under for more than the predetermined period of time copyir.com • While the IH heater was on, input power was at the high voltage detection value or over for more than the predetermined period of time copyir.com • While the IH heater was on, input power was below the low voltage detection value or under for more than the predetermined period of time copyir.com • While the IH heater was on, inverter power stayed at the upper limit value or over for more than the predetermined period of time copyir.com • While the IH heater was on, output voltage halt was detected copyir.com
C3B08 IH input voltage error
• While the IH heater was on, input power was at the high voltage detection value or over for more than the predetermined period of time copyir.com • While the IH heater was on, input voltage was at the low power detection value or under for more than the predetermined period of time copyir.com
C4101 Polygon motor rotation trouble
• The polygon motor fails to turn stably even after the lapse of a given period of time after activating the polygon motor copyir.com • Motor lock signal detects HIGH for a given period time consecutively during the polygon motor is rotating copyir.com
C4301 PH cooling fan motor failure to turn
• The fan motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary copyir.com
C4501 Laser malfunction
• SOS signal is not detected even after the lapse of a given period of time after staring the laser output copyir.com • SOS signal is not detected for a given period of time during printing or IDC sensor adjustment copyir.com
C5104 Transfer belt motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary copyir.com
C5105 Transfer belt motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary copyir.com
C5304 IH cooling fan motor/1’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary copyir.com
C5306 IH cooling fan motor/2’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary copyir.com
C5351 Power supply cooling fan motor/1’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary copyir.com
C5354 Ozone ventilation fan motor’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary copyir.com
C5356 Cooling fan motor’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary copyir.com
C5370 MFP control board cooling fan motor’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary copyir.com
C5372 MFP control board CPU temperature failure
• Temperature failure of CPU on the MFP board was detected copyir.com
C6001 ADF related configuration error 1
• Inconsistency in the configuration is detected with the installed ADF copyir.com
C6002 ADF related configuration error 2
<bizhub C652/C552/C452> • The machine detects an ADF other than DF618 copyir.com <bizhub C652DS/C552DS> • The machine detects an ADF other than DF619 copyir.com
C6102 Drive system home sensor malfunction
• The scanner home sensor is unable to detect the scanner located at its home position copyir.com • The scanner home sensor is unable to detect a scanner even when the scanner motor has been driven to move the scanner over the maximum travelling distance copyir.com • The scanner home sensor detects the scanner when the scanner has moved the maximum travelling distance from the position, at which it blocks the scanner home sensor copyir.com
C6103 Slider over running
• The scanner home sensor detects the scanner at its home position during a period of time that begins with the time when a pre-scan command and a scan preparation command are executed and ends when a home return command is executed copyir.com
C6104 Opposed board home sensor abnormality (initial)
• The back side cleaning sensor (PS9) does not change from H to L even after the lapse of a given period of time after the home position detecting operation is started at the initial operation copyir.com • The back side cleaning sensor (PS9) does not change from L to H even after the lapse of a given period of time after the home position detecting operation is started at the initial operation copyir.com
C6105 Opposed board home sensor abnormality (normal)
• At the time of operation other than the initial operation, the back side cleaning sensor (PS9) error is detected copyir.com
C6301 Optical cooling fan motor’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary copyir.com
C6303 CIS cooling fan motor’s failure to turn
• While the motor is running, the fan lock signal remains HIGH three times for a predetermined period of consecutive time copyir.com
C6704 Image input time out
• Image data is not input from the scanner to the MFP board (MFPB) copyir.com
C6751 CCD clamp/gain adjustment failure
• The adjustment value is 0 or 255 during a CCD clamp adjustment copyir.com • The peak value of the output data is 64 or less during a CCD gain adjustment copyir.com
C6752 ASIC clock input error (front side)
• When starting the scanner, verification on reading and writing the predetermined value for image processing ASIC on CCD board was conducted, and verification failure was detected copyir.com
C6753 ASIC clock input error (back side)
• When starting the scanner, verification on reading and writing the predetermined value for image processing ASIC on CCD board was conducted, and verification failure was detected copyir.com
C6754 CIS clamp adjustment failure
• After the gain adjustment is performed at the start-up, the CIS clamp adjustment value is too high or too low copyir.com
C6755 CIS gain adjustment failure
• After the gain adjustment is performed at the start-up, the peak value of the output data is lower than a given value copyir.com
C6901 DSC board mount failure 1
• When MFP detects that DSC board (front side) is not properly installed copyir.com
C6902, C6903 DSC Bus check NG1
• When DSC bus check (front side) detects an error copyir.com
C6911 DSC board mount failure 2
• When MFP detects that DSC board (back side) is not properly installed copyir.com
C6912, C6913 DSC Bus check NG2
• When DSC bus check (back side) detects an error copyir.com
C6F01 Scanner sequence trouble 1
• The original transport interval becomes shorter than the designed value due to an original transport control error in original reading in ADF copyir.com
C8101 Before reading pressure welding alienation mechanism
•During a pressure motion being performed, the read roller sensor (PS6) output does not change from H to L copyir.com •During a retraction motion being performed, the read roller sensor (PS6) output does not change from L to H copyir.com
C8102 Turn around pressure welding alienation trouble
•During a pressure motion being performed, the reverse roller sensor (PS7) output does not change from H to L copyir.com •During a retraction motion being performed, the reverse roller sensor (PS7) output does not change from L to H copyir.com
C8103 Lift up mechanism trouble (Upward movement)
• The lift up upper sensor (PS16) is not turned ON after a lapse of a given time after the lift-up motor (M6) moves up (is turned forward) copyir.com
C8104 Glass movement trouble
• The glass home sensor (PS203) output does not change from H to L after a lapse of a given time while the original glass moving motor (M202) is working copyir.com • The glass home sensor (PS203) output does not change from L to H after a lapse of a given time while the original glass moving motor (M202) is working copyir.com
C8106 Lift up mechanism failure (Downward movement)
• The lift up lower sensor (PS15) is not turned ON after a lapse of a given time after the lift-up motor (M6) goes down (is turned backward) copyir.com
C8107 Glass cleaning mechanism trouble
• The front side cleaning sensor (PS18) is not turned ON after the set period of time has elapsed after the front side cleaning motor (M8) is turned ON copyir.com
C8302 Cooling fan failure
• While the motor is running, the fan lock signal remains HIGH three times for a predetermined period of consecutive time copyir.com
C8401 EEPROM failure
• EEPROM does not access normally
C9401 Exposure turning on the lamp trouble detection
• The output from the CCD sensor is a predetermined value or less during CCD sensor gain adjustment copyir.com
C9402 Exposure turning on the lamp abnormally detection
• The average output value of the CCD sensor with the scanner at its standby position is a predetermined value or more at the end of a scan job copyir.com
C9403 CIS exposure turning on the lamp trouble detection
• At the CIS gain adjustment, the machine detected that the output of the CIS exposure lamp is lower than the specified value copyir.com
C9404 CIS exposure turning on the lamp abnormally detection
• After a scan job is completed, the machine detected that the average output of the CIS exposure lamp is greater than the specified value copyir.com
CA051 Standard controller configuration failure
• The controller of the printer control board (PRCB) is faulty copyir.com
CA052 Controller hardware error
• A controller hardware error is detected in the network I/F copyir.com
CA053 Controller start failure
• A controller start failure is detected in the controller interface copyir.com
CB001 copyir.com copyir.com copyir.com CB119 FAX Board Error
CD004 copyir.com copyir.com copyir.com CD011 HDD error
CF001 copyir.com copyir.com copyir.com CFF15 MFP Control Board error
یک پاسخ
سلامو اگر ممکنه ترجمه و مورد ممکن برای رفع خطا یا موارد نیاز به سرویس را مشخص کنید تا بتونیم بهتر در مورد تعمیر و نگهداری دستگاهها تصمیم بگیریم.سپاس