C0000 Main Motor’s failure to turn
• The Lock signal does not go LOW within 1 s after the motor has been energized copyir.com • The Lock signal remains HIGH for continuous 0 copyir.com1 s or more while the motor remains energized copyir.com 1 Main Motor turns after the malfunction has been reset copyir.com NO Correct drive copyir.com 2 Main Motor operation: the voltage across PJ6A-3 on the Master Board and GND is DC5 V (motor deenergized) and DC0 V (motor energized) after the malfunction has been reset copyir.com NO Change Master Board copyir.com 3 The voltage across PJ6A-4 on the Master Board and GND is DC5 V (motor deenergized) and DC0 V (motor energized) after the malfunction has been reset copyir.com YES Change Master Board copyir.com NO Change motor copyir.com
C0045 Fusing Section Cooling Fan Motor’s failure to turn
A voltage of 0 copyir.com3 V or less is detected for a continuous 1 s period while the motor remains energized copyir.com 1 Fusing Section Cooling Fan Motor operation: the voltage across CN7-2 on the Power Supply Board and GND is DC24 V after the malfunction has been reset copyir.com NO Change Power Supply Board copyir.com 2 Fusing Section Cooling Fan Motor operation: the voltage across CN7-1 on the Power Supply Board and GND is DC1 copyir.com2 V (during high-speed rotation) and DC12 V (during low-speed rotation) after the malfunction has been reset copyir.com YES Change motor copyir.com NO Change Power Supply Board copyir.com Change Master Board copyir.com
C0049 PH Section Cooling Fan Motor’s failure to turn
A voltage of 0 copyir.com35 V or less is detected for a continuous 0 copyir.com5 s period while the motor remains energized copyir.com 1 PH Section Cooling Fan Motor operation: the voltage across PJ13A-2 on the Master Board and GND is DC24 V after the malfunction has been reset copyir.com NO Change Master Board copyir.com 2 PH Section Cooling Fan Motor operation: the voltage across PJ13A-1 on the Master Board and GND is DC1 V (motor energized) and DC24 V (motor deenergized) after the malfunction has been reset copyir.com YES Change motor copyir.com NO Change Master Board copyir.com
C0200 HV output failure
• The drum charge monitor voltage is lower than 4 copyir.com5 V when the power switch is turned ON copyir.com • The drum charge monitor voltage remains 4 copyir.com5 V or more when the drum charge output is turned ON copyir.com • The image transfer monitor voltage is 0 copyir.com5 V or more immediately before the image transfer output is turned ON copyir.com • The image transfer monitor voltage does not increase 0 copyir.com5 V or more within 40 ms after the image transfer output is turned ON copyir.com 1 High Voltage Unit operation: the voltage across PJ4A-4 on the Master Board and GND is DC24 V after the malfunction has been reset copyir.com YES Change High Voltage Unit copyir.com 2 Proper connection between the High Voltage Unit and Master Board copyir.com YES Change Master Board copyir.com NO Correct connection copyir.com
C0500 Warm-up failure
• During the period from 12 s to 30 s after the start of the warm-up cycle, a condition of small temperature difference from the temperature at the start of the warm-up cycle is detected for a 50 ms period copyir.com • The temperature detected by the Thermistor does not reach the set level within 120 s after the start of the warm-up cycle copyir.com 1 Fusing Heater Lamp turns ON after the malfunction has been reset copyir.com YES Correct Thermistor for mounting position and/or clean copyir.com 2 Thermistor operation: resistance across CN1-1 and 2 on the Fusing Unit side is infinite, as measured with CN1 disconnected copyir.com YES Change Thermistor copyir.com 3 Thermoswitch and Fusing Heater Lamp operation: there is continuity across CN14-1 and 2 on the Fusing Unit side, as measured with CN14 disconnected copyir.com NO Change Thermoswitch copyir.com Change Fusing Heater Lamp copyir.com 4 The voltage across PJ14A-3 on the Master Board and GND is DC0 V (Fusing Heater Lamp ON) and DC24 V (Fusing Heater Lamp OFF) after the malfunction has been reset copyir.com YES Change Power Supply Board copyir.com Change Fuse 2 of Power Supply Board copyir.com NO Change Master Board copyir.com
C0510 Abnormally low fusing temperature
• The temperature detected by the Thermistor remains lower than 94 °C for a continuous 50 ms period while the copier is in the standby state copyir.com • The temperature detected by the Thermistor remains lower than 110 °C for a continuous 50 ms period during a copy cycle copyir.com 1 Fusing Heater Lamp turns ON after the malfunction has been reset copyir.com YES Correct Thermistor for mounting position and/or clean copyir.com 2 Thermistor operation: resistance across CN1-1 and 2 on the Fusing Unit side is infinite, as measured with CN1 disconnected copyir.com YES Change Thermistor copyir.com 3 Thermoswitch and Fusing Heater Lamp operation: there is continuity across CN14-1 and 2 on the Fusing Unit side, as measured with CN14 disconnected copyir.com NO Change Thermoswitch copyir.com Change Fusing Heater Lamp copyir.com 4 The voltage across PJ14A-3 on the Master Board and GND is DC0 V (Fusing Heater Lamp ON) and DC24 V (Fusing Heater Lamp OFF) after the malfunction has been reset copyir.com YES Change Power Supply Board copyir.com Change Fuse 2 of Power Supply Board copyir.com NO Change Master Board copyir.com
C0520 Abnormally high fusing temperature
The temperature detected by the Thermistor remains higher than 240 °C for a continuous 50 ms period while fusing temperature control is in progress copyir.com 1 Thermistor installed at the correct position copyir.com NO Correct copyir.com 2 Thermistor contaminated copyir.com YES Clean copyir.com 3 The circuit across CN1-1 and 2 on the Fusing Unit side is shorted as checked with CN1 disconnected copyir.com YES Change Thermistor copyir.com NO Change Master Board copyir.com Change Power Supply Board copyir.com
C0650 Scanner Motor’s failure to turn, Scanner Home Position Sensor malfunction
The Scanner Home Position Sensor is not activated within a given period of time after the Scanner Motor has been energized copyir.com 1 Scanner movement after the malfunction has been reset YES To step 4 2 Scanner motion as it is moved manually NO Correct drive coupling copyir.com Install belt copyir.com 3 Proper JP9 connector connection of Control Board YES Change Scanner Motor copyir.com Change Control Board copyir.com NO Correct connections copyir.com 4 Scanner Home Position Sensor operation: the voltage across JP14-1 on the Control Board and GND is DC0 V (sensor unblocked) and DC3 V (sensor blocked) after the malfunction has been reset copyir.com YES Change Control Board copyir.com NO Change sensor copyir.com
C1200 System memory failure
A memory test error is detected during the power-on initialization procedure copyir.com 1 copyir.com Reset the malfunction copyir.com 2 copyir.com If the malfunction is detected again, check the Control Board and Memory Board for proper connections copyir.com 3 copyir.com If connections are okay, change the Control Board and/or Memory Board copyir.com
C1300 Polygon Motor malfunction
• During the period 6 s after the Polygon Motor has been energized, a cluster of 56 or more SOS signals output for a 20 ms period is detected five consecutive times copyir.com • After the lapse of 6 s after the Polygon Motor has been energized, a cluster of below 43 or above 56 SOS signals output for a 20 ms period is detected five consecutive times copyir.com • No SOS signal is detected during the period from the start of laser emission to the deenergization of the Polygon Motor copyir.com 1 copyir.com Reset the malfunction copyir.com 2 copyir.com If the malfunction is detected again, check the harness between, and PJ connections on, the PH Unit and Master Board copyir.com 3 copyir.com If connections are okay, change the PH Unit and Master Board copyir.com
C133B Option communications error
The Controller Board is not detected within 5 s after the start of a print cycle copyir.com 1 copyir.com Reset the malfunction copyir.com 2 copyir.com If the malfunction is detected again, check the Control Board and the controller board copyir.com 3 copyir.com If connections are okay, change the Control Board and the controller board copyir.com
C13F0 SOS detection failure
• During the period 6 s after the Polygon Motor has been energized, a cluster of 56 or more SOS signals output for a 20 ms period is detected five consecutive times copyir.com • After the lapse of 6 s after the Polygon Motor has been energized, a cluster of below 43 or above 56 SOS signals output for a 20 ms period is detected five consecutive times copyir.com • No SOS signal is detected during the period from the start of laser emission to the deenergization of the Polygon Motor copyir.com 1 copyir.com Reset the malfunction copyir.com 2 copyir.com If the malfunction is detected again, check the harness between, and PJ connections on, the PH Unit and Master Board copyir.com 3 copyir.com If connections are okay, change the PH Unit and Master Board copyir.com
C1468 Hardware (EEPROM) malfunction
An EEPROM read/write error occurs during the power-on initialization procedure copyir.com 1 copyir.com Run “FA” of Function copyir.com 2 copyir.com If it has not been checked okay (“FF” appears on the display), change the EEPROM on the Control Board copyir.com If it has been checked okay (“00” appears on the display), change the Control Board itself copyir.com
C14A3 Exposure Lamp malfunction
The intensity level of the Exposure Lamp does not stabilize within a given period of time copyir.com 1 Proper connections between the Scanner, Scanner Interface Board, and Control Board YES Change Scanner Interface Board copyir.com Change Control Board copyir.com Change Scanner copyir.com NO Correct connections copyir.com
C0000 Main Motor’s failure to turn
• The Lock signal does not go LOW within 1 s after the motor has been energized copyir.com • The Lock signal remains HIGH for continuous 0 copyir.com1 s or more while the motor remains energized copyir.com 1 Main Motor turns after the malfunction has been reset copyir.com NO Correct drive copyir.com 2 Main Motor operation: the voltage across PJ6A-3 on the Master Board and GND is DC5 V (motor deenergized) and DC0 V (motor energized) after the malfunction has been reset copyir.com NO Change Master Board copyir.com 3 The voltage across PJ6A-4 on the Master Board and GND is DC5 V (motor deenergized) and DC0 V (motor energized) after the malfunction has been reset copyir.com YES Change Master Board copyir.com NO Change motor copyir.com
C0045 Fusing Section Cooling Fan Motor’s failure to turn
A voltage of 0 copyir.com3 V or less is detected for a continuous 1 s period while the motor remains energized copyir.com 1 Fusing Section Cooling Fan Motor operation: the voltage across CN7-2 on the Power Supply Board and GND is DC24 V after the malfunction has been reset copyir.com NO Change Power Supply Board copyir.com 2 Fusing Section Cooling Fan Motor operation: the voltage across CN7-1 on the Power Supply Board and GND is DC1 copyir.com2 V (during high-speed rotation) and DC12 V (during low-speed rotation) after the malfunction has been reset copyir.com YES Change motor copyir.com NO Change Power Supply Board copyir.com Change Master Board copyir.com
C0049 PH Section Cooling Fan Motor’s failure to turn
A voltage of 0 copyir.com35 V or less is detected for a continuous 0 copyir.com5 s period while the motor remains energized copyir.com 1 PH Section Cooling Fan Motor operation: the voltage across PJ13A-2 on the Master Board and GND is DC24 V after the malfunction has been reset copyir.com NO Change Master Board copyir.com 2 PH Section Cooling Fan Motor operation: the voltage across PJ13A-1 on the Master Board and GND is DC1 V (motor energized) and DC24 V (motor deenergized) after the malfunction has been reset copyir.com YES Change motor copyir.com NO Change Master Board copyir.com
C0200 HV output failure
• The drum charge monitor voltage is lower than 4 copyir.com5 V when the power switch is turned ON copyir.com • The drum charge monitor voltage remains 4 copyir.com5 V or more when the drum charge output is turned ON copyir.com • The image transfer monitor voltage is 0 copyir.com5 V or more immediately before the image transfer output is turned ON copyir.com • The image transfer monitor voltage does not increase 0 copyir.com5 V or more within 40 ms after the image transfer output is turned ON copyir.com 1 High Voltage Unit operation: the voltage across PJ4A-4 on the Master Board and GND is DC24 V after the malfunction has been reset copyir.com YES Change High Voltage Unit copyir.com 2 Proper connection between the High Voltage Unit and Master Board copyir.com YES Change Master Board copyir.com NO Correct connection copyir.com
C0500 Warm-up failure
• During the period from 12 s to 30 s after the start of the warm-up cycle, a condition of small temperature difference from the temperature at the start of the warm-up cycle is detected for a 50 ms period copyir.com • The temperature detected by the Thermistor does not reach the set level within 120 s after the start of the warm-up cycle copyir.com 1 Fusing Heater Lamp turns ON after the malfunction has been reset copyir.com YES Correct Thermistor for mounting position and/or clean copyir.com 2 Thermistor operation: resistance across CN1-1 and 2 on the Fusing Unit side is infinite, as measured with CN1 disconnected copyir.com YES Change Thermistor copyir.com 3 Thermoswitch and Fusing Heater Lamp operation: there is continuity across CN14-1 and 2 on the Fusing Unit side, as measured with CN14 disconnected copyir.com NO Change Thermoswitch copyir.com Change Fusing Heater Lamp copyir.com 4 The voltage across PJ14A-3 on the Master Board and GND is DC0 V (Fusing Heater Lamp ON) and DC24 V (Fusing Heater Lamp OFF) after the malfunction has been reset copyir.com YES Change Power Supply Board copyir.com Change Fuse 2 of Power Supply Board copyir.com NO Change Master Board copyir.com
C0510 Abnormally low fusing temperature
• The temperature detected by the Thermistor remains lower than 94 °C for a continuous 50 ms period while the copier is in the standby state copyir.com • The temperature detected by the Thermistor remains lower than 110 °C for a continuous 50 ms period during a copy cycle copyir.com 1 Fusing Heater Lamp turns ON after the malfunction has been reset copyir.com YES Correct Thermistor for mounting position and/or clean copyir.com 2 Thermistor operation: resistance across CN1-1 and 2 on the Fusing Unit side is infinite, as measured with CN1 disconnected copyir.com YES Change Thermistor copyir.com 3 Thermoswitch and Fusing Heater Lamp operation: there is continuity across CN14-1 and 2 on the Fusing Unit side, as measured with CN14 disconnected copyir.com NO Change Thermoswitch copyir.com Change Fusing Heater Lamp copyir.com 4 The voltage across PJ14A-3 on the Master Board and GND is DC0 V (Fusing Heater Lamp ON) and DC24 V (Fusing Heater Lamp OFF) after the malfunction has been reset copyir.com YES Change Power Supply Board copyir.com Change Fuse 2 of Power Supply Board copyir.com NO Change Master Board copyir.com
C0520 Abnormally high fusing temperature
The temperature detected by the Thermistor remains higher than 240 °C for a continuous 50 ms period while fusing temperature control is in progress copyir.com 1 Thermistor installed at the correct position copyir.com NO Correct copyir.com 2 Thermistor contaminated copyir.com YES Clean copyir.com 3 The circuit across CN1-1 and 2 on the Fusing Unit side is shorted as checked with CN1 disconnected copyir.com YES Change Thermistor copyir.com NO Change Master Board copyir.com Change Power Supply Board copyir.com
C0650 Scanner Motor’s failure to turn, Scanner Home Position Sensor malfunction
The Scanner Home Position Sensor is not activated within a given period of time after the Scanner Motor has been energized copyir.com 1 Scanner movement after the malfunction has been reset YES To step 4 2 Scanner motion as it is moved manually NO Correct drive coupling copyir.com Install belt copyir.com 3 Proper JP9 connector connection of Control Board YES Change Scanner Motor copyir.com Change Control Board copyir.com NO Correct connections copyir.com 4 Scanner Home Position Sensor operation: the voltage across JP14-1 on the Control Board and GND is DC0 V (sensor unblocked) and DC3 V (sensor blocked) after the malfunction has been reset copyir.com YES Change Control Board copyir.com NO Change sensor copyir.com
C1200 System memory failure
A memory test error is detected during the power-on initialization procedure copyir.com 1 copyir.com Reset the malfunction copyir.com 2 copyir.com If the malfunction is detected again, check the Control Board and Memory Board for proper connections copyir.com 3 copyir.com If connections are okay, change the Control Board and/or Memory Board copyir.com
C1300 Polygon Motor malfunction
• During the period 6 s after the Polygon Motor has been energized, a cluster of 56 or more SOS signals output for a 20 ms period is detected five consecutive times copyir.com • After the lapse of 6 s after the Polygon Motor has been energized, a cluster of below 43 or above 56 SOS signals output for a 20 ms period is detected five consecutive times copyir.com • No SOS signal is detected during the period from the start of laser emission to the deenergization of the Polygon Motor copyir.com 1 copyir.com Reset the malfunction copyir.com 2 copyir.com If the malfunction is detected again, check the harness between, and PJ connections on, the PH Unit and Master Board copyir.com 3 copyir.com If connections are okay, change the PH Unit and Master Board copyir.com
C133B Option communications error
The Controller Board is not detected within 5 s after the start of a print cycle copyir.com 1 copyir.com Reset the malfunction copyir.com 2 copyir.com If the malfunction is detected again, check the Control Board and the controller board copyir.com 3 copyir.com If connections are okay, change the Control Board and the controller board copyir.com
C13F0 SOS detection failure
• During the period 6 s after the Polygon Motor has been energized, a cluster of 56 or more SOS signals output for a 20 ms period is detected five consecutive times copyir.com • After the lapse of 6 s after the Polygon Motor has been energized, a cluster of below 43 or above 56 SOS signals output for a 20 ms period is detected five consecutive times copyir.com • No SOS signal is detected during the period from the start of laser emission to the deenergization of the Polygon Motor copyir.com 1 copyir.com Reset the malfunction copyir.com 2 copyir.com If the malfunction is detected again, check the harness between, and PJ connections on, the PH Unit and Master Board copyir.com 3 copyir.com If connections are okay, change the PH Unit and Master Board copyir.com
C1468 Hardware (EEPROM) malfunction
An EEPROM read/write error occurs during the power-on initialization procedure copyir.com 1 copyir.com Run “FA” of Function copyir.com 2 copyir.com If it has not been checked okay (“FF” appears on the display), change the EEPROM on the Control Board copyir.com If it has been checked okay (“00” appears on the display), change the Control Board itself copyir.com
C14A3 Exposure Lamp malfunction
The intensity level of the Exposure Lamp does not stabilize within a given period of time copyir.com 1 Proper connections between the Scanner, Scanner Interface Board, and Control Board YES Change Scanner Interface Board copyir.com Change Control Board copyir.com Change Scanner copyir.com NO Correct connections copyir.com