C0000    Main Motor malfunction
• The Main Motor (M1) Lock signal remains HIGH for a continuous 1   copyir.comsec. period at any time 1 sec. after the Main Motor has started turning.    1 Check M1 connectors for proper connection and correct as necessary. 2 Check M1 for correct drive coupling and correct as necessary. 3 M1 operation check. 4 Change PWB   copyir.comA. 5 Change PU1.
C0044    ADF Cooling Fan Failure (Only when the optional DF is mounted)
• The ADF Fan Motor Lock signal remains set to H for a set period of time while the EDH Fan Motor is turning.    1 Check the motor connectors for paper connection, and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 M3   copyir.comADF operation check. 4 Replace PBA   copyir.comCONT.
C0045    Fusing Cooling Fan Motor malfunction
copyir.com The Fusing Cooling Fan Motor (M3) Lock signal remains HIGH for a continuous 1   copyir.comsec. period while the Fusing Cooling Fan Motor is turning at full speed or decelerated speed.    1 Check M3 connectors for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M3 operation check 4 Change PWB   copyir.comA. 5 Change PU1.
C004E    Power Supply Cooling Fan Motor malfunction
copyir.com The Power Supply Cooling Fan Motor (M4) Lock signal remains HIGH for a continuous 1   copyir.comsec. period while the Power Supply Cooling Fan Motor Remote signal remains ON (for full   copyir.comspeed rotation) or OFF (for decelerated   copyir.comspeed rotation).    1 Check M4 connectors for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M4 operation check 4 Change PWB   copyir.comA. 5 Change PU1.
C0070    Toner Replenishing Motor malfunction
copyir.com The Toner Bottle Home Position Sensor (PC7) outputs a HIGH signal for a continuous 3.5   copyir.comsec. period while the Toner Bottle is turning.
copyir.com The Toner Bottle Home Position Sensor (PC7) outputs a LOW signal for a continuous 2   copyir.comsec. period while the Toner Bottle is turning.    1 Check M6 connectors for proper connection and correct as necessary. 2 Check M6 for correct drive coupling and correct as necessary. 3 M6 operation check 4 PC7 sensor check 5 Change PWB   copyir.comA. 6 Change PU1.
C0210    Abnormal image transfer voltage
copyir.com The image transfer voltage remains more than 100 V continuously for a given period of time while the PC Drum remains stationary.    1 Check the Image Transfer Roller for installation. 2 Change HV1. 3 Change PWB   copyir.comA.
C03FF    Faulty Model Setting
copyir.com “Model Setting” of “Adjust” available from the Service mode is incorrectly set.
C0500    Warm   copyir.comup failure
copyir.com The surface temperature of the Fusing Roller does not reach a given level even after the lapse of a given period of time during a warm   copyir.comup cycle.    1 Check that the Fusing Roller Heater Lamp (H1) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 2 Check that the Fusing Roller Sub Heater Lamp (H2) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 3 Check the Fusing Roller Thermostat (TS1) for operation. <Check procedure> Check the resistance of TS1. TS1 is open   copyir.comcircuited if its resistance is infinity. 4 Check the Fusing Unit Interlock Switch (S2) for operation. <Check procedure> Check continuity across the following terminals when S2 is ON. • Across S2   copyir.com1A and S2   copyir.com1B • Across S2   copyir.com2A and S2   copyir.com2B 5 Check the Fusing Roller Thermistor (TH1) and Fusing Roller Sub Thermistor (TH2) for installation and correct or clean as necessary. 6 Check the Fusing Roller Thermistor (TH1) for operation. <Check procedure> Disconnect CN15 (4P) and check the resistance across CN15   copyir.com2 and 3 on the Thermistor side. TH1 is open   copyir.comcircuited if the resistance is infinity. 7 Check the Fusing Roller Sub Thermistor (TH2) for operation. <Check procedure> Disconnect CN22 (4P) and check the resistance across CN22   copyir.com2 and 3 on the Thermistor side. TH2 is open   copyir.comcircuited if the resistance is infinity. 8 Check the Fusing Roller Heater Lamp (H1) for continuity and correct or replace as necessary. 9 Check the Fusing Roller Sub Heater Lamp (H2) for continuity and correct or replace as necessary. 10 Change PU1. 11 Change PWB   copyir.comA.
C0501    Warm   copyir.comup failure 2 (for the model having two Fusing Roller Heater Lamps)
copyir.com The Fusing Roller Sub Thermistor does not detect a predetermined temperature within 30 sec. after a warm   copyir.comup cycle has been started and thus the warm   copyir.comup cycle is not completed.
copyir.com The surface temperature of the Fusing Roller does not reach a given level even after the lapse of a given period of time during a warm   copyir.comup cycle.    1 Check that the Fusing Roller Heater Lamp (H1) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 2 Check that the Fusing Roller Sub Heater Lamp (H2) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 3 Check the Fusing Roller Thermostat (TS1) for operation. <Check procedure> Check the resistance of TS1. TS1 is open   copyir.comcircuited if its resistance is infinity. 4 Check the Fusing Unit Interlock Switch (S2) for operation. <Check procedure> Check continuity across the following terminals when S2 is ON. • Across S2   copyir.com1A and S2   copyir.com1B • Across S2   copyir.com2A and S2   copyir.com2B 5 Check the Fusing Roller Thermistor (TH1) and Fusing Roller Sub Thermistor (TH2) for installation and correct or clean as necessary. 6 Check the Fusing Roller Thermistor (TH1) for operation. <Check procedure> Disconnect CN15 (4P) and check the resistance across CN15   copyir.com2 and 3 on the Thermistor side. TH1 is open   copyir.comcircuited if the resistance is infinity. 7 Check the Fusing Roller Sub Thermistor (TH2) for operation. <Check procedure> Disconnect CN22 (4P) and check the resistance across CN22   copyir.com2 and 3 on the Thermistor side. TH2 is open   copyir.comcircuited if the resistance is infinity. 8 Check the Fusing Roller Heater Lamp (H1) for continuity and correct or replace as necessary. 9 Check the Fusing Roller Sub Heater Lamp (H2) for continuity and correct or replace as necessary. 10 Change PU1. 11 Change PWB   copyir.comA.
C0510    Fusing failure (abnormally low fusing temperature)
copyir.com The temperature detected by the Fusing Roller Thermistor remains lower than 120°C (105°C for the model having two Fusing Roller Heater Lamps) for a given period of time during the standby state.
copyir.com The temperature detected by the Fusing Roller Thermistor remains lower than 120°C (105°C for the model having two Fusing Roller Heater Lamps) for a given period of time during a print cycle.    1 Check that the Fusing Roller Heater Lamp (H1) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 2 Check that the Fusing Roller Sub Heater Lamp (H2) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 3 Check the Fusing Roller Thermostat (TS1) for operation. <Check procedure> Check the resistance of TS1. TS1 is open   copyir.comcircuited if its resistance is infinity. 4 Check the Fusing Unit Interlock Switch (S2) for operation. <Check procedure> Check continuity across the following terminals when S2 is ON. • Across S2   copyir.com1A and S2   copyir.com1B • Across S2   copyir.com2A and S2   copyir.com2B 5 Check the Fusing Roller Thermistor (TH1) and Fusing Roller Sub Thermistor (TH2) for installation and correct or clean as necessary. 6 Check the Fusing Roller Thermistor (TH1) for operation. <Check procedure> Disconnect CN15 (4P) and check the resistance across CN15   copyir.com2 and 3 on the Thermistor side. TH1 is open   copyir.comcircuited if the resistance is infinity. 7 Check the Fusing Roller Sub Thermistor (TH2) for operation. <Check procedure> Disconnect CN22 (4P) and check the resistance across CN22   copyir.com2 and 3 on the Thermistor side. TH2 is open   copyir.comcircuited if the resistance is infinity. 8 Check the Fusing Roller Heater Lamp (H1) for continuity and correct or replace as necessary. 9 Check the Fusing Roller Sub Heater Lamp (H2) for continuity and correct or replace as necessary. 10 Change PU1. 11 Change PWB   copyir.comA.
C0511    Fusing failure (abnormally low fusing temperature 2)
copyir.com The temperature detected by the Fusing Roller Sub Thermistor remains lower than 105°C for a given period of time during the standby state.
copyir.com The temperature detected by the Fusing Roller Sub Thermistor remains lower than 105°C for a given period of time during a print cycle.    1 Check that the Fusing Roller Heater Lamp (H1) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 2 Check that the Fusing Roller Sub Heater Lamp (H2) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 3 Check the Fusing Roller Thermostat (TS1) for operation. <Check procedure> Check the resistance of TS1. TS1 is open   copyir.comcircuited if its resistance is infinity. 4 Check the Fusing Unit Interlock Switch (S2) for operation. <Check procedure> Check continuity across the following terminals when S2 is ON. • Across S2   copyir.com1A and S2   copyir.com1B • Across S2   copyir.com2A and S2   copyir.com2B 5 Check the Fusing Roller Thermistor (TH1) and Fusing Roller Sub Thermistor (TH2) for installation and correct or clean as necessary. 6 Check the Fusing Roller Thermistor (TH1) for operation. <Check procedure> Disconnect CN15 (4P) and check the resistance across CN15   copyir.com2 and 3 on the Thermistor side. TH1 is open   copyir.comcircuited if the resistance is infinity. 7 Check the Fusing Roller Sub Thermistor (TH2) for operation. <Check procedure> Disconnect CN22 (4P) and check the resistance across CN22   copyir.com2 and 3 on the Thermistor side. TH2 is open   copyir.comcircuited if the resistance is infinity. 8 Check the Fusing Roller Heater Lamp (H1) for continuity and correct or replace as necessary. 9 Check the Fusing Roller Sub Heater Lamp (H2) for continuity and correct or replace as necessary. 10 Change PU1. 11 Change PWB   copyir.comA.
C0520    Fusing failure (abnormally high fusing temperature 2)
copyir.com The temperature detected by the Fusing Roller Thermistor remains higher than 240°C for a given period of time.    1 Check that the Fusing Roller Heater Lamp (H1) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 2 Check that the Fusing Roller Sub Heater Lamp (H2) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 3 Check the Fusing Roller Thermostat (TS1) for operation. <Check procedure> Check the resistance of TS1. TS1 is open   copyir.comcircuited if its resistance is infinity. 4 Check the Fusing Unit Interlock Switch (S2) for operation. <Check procedure> Check continuity across the following terminals when S2 is ON. • Across S2   copyir.com1A and S2   copyir.com1B • Across S2   copyir.com2A and S2   copyir.com2B 5 Check the Fusing Roller Thermistor (TH1) and Fusing Roller Sub Thermistor (TH2) for installation and correct or clean as necessary. 6 Check the Fusing Roller Thermistor (TH1) for operation. <Check procedure> Disconnect CN15 (4P) and check the resistance across CN15   copyir.com2 and 3 on the Thermistor side. TH1 is open   copyir.comcircuited if the resistance is infinity. 7 Check the Fusing Roller Sub Thermistor (TH2) for operation. <Check procedure> Disconnect CN22 (4P) and check the resistance across CN22   copyir.com2 and 3 on the Thermistor side. TH2 is open   copyir.comcircuited if the resistance is infinity. 8 Check the Fusing Roller Heater Lamp (H1) for continuity and correct or replace as necessary. 9 Check the Fusing Roller Sub Heater Lamp (H2) for continuity and correct or replace as necessary. 10 Change PU1. 11 Change PWB   copyir.comA.
C0521    Fusing failure (abnormally high fusing temperature 2)
copyir.com The temperature detected by the Fusing Roller Sub Thermistor remains higher than 240°C for a given period of time.    1 Check that the Fusing Roller Heater Lamp (H1) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 2 Check that the Fusing Roller Sub Heater Lamp (H2) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 3 Check the Fusing Roller Thermostat (TS1) for operation. <Check procedure> Check the resistance of TS1. TS1 is open   copyir.comcircuited if its resistance is infinity. 4 Check the Fusing Unit Interlock Switch (S2) for operation. <Check procedure> Check continuity across the following terminals when S2 is ON. • Across S2   copyir.com1A and S2   copyir.com1B • Across S2   copyir.com2A and S2   copyir.com2B 5 Check the Fusing Roller Thermistor (TH1) and Fusing Roller Sub Thermistor (TH2) for installation and correct or clean as necessary. 6 Check the Fusing Roller Thermistor (TH1) for operation. <Check procedure> Disconnect CN15 (4P) and check the resistance across CN15   copyir.com2 and 3 on the Thermistor side. TH1 is open   copyir.comcircuited if the resistance is infinity. 7 Check the Fusing Roller Sub Thermistor (TH2) for operation. <Check procedure> Disconnect CN22 (4P) and check the resistance across CN22   copyir.com2 and 3 on the Thermistor side. TH2 is open   copyir.comcircuited if the resistance is infinity. 8 Check the Fusing Roller Heater Lamp (H1) for continuity and correct or replace as necessary. 9 Check the Fusing Roller Sub Heater Lamp (H2) for continuity and correct or replace as necessary. 10 Change PU1. 11 Change PWB   copyir.comA.
C0650    Faulty Scanner Home Position Sensor
copyir.com The Scanner Home Position Sensor (PC10) does not go from HIGH to LOW when the Scanner Motor (M5) is energized for a given number of steps after the sequence to bring the Scanner back to its home position has been started at the end of a scan motion and during re   copyir.comshading.
copyir.com The Scanner Home Position Sensor (PC10) does not go from LOW to HIGH when the Scanner Motor (M5) is energized for a given number of steps after a scan motion has been started at the end of a Scanner Home Position Sensor home check scan motion and during re   copyir.comshading.    1 Check M5 connectors for proper connection and correct as necessary. 2 Check M5 for correct drive coupling and correct as necessary. 3 M5 operation check 4 Scanner operation check 5 PC10 sensor check 6 Change PWB   copyir.comC/C.
C0B60    Bin Switching Motor malfunction (Only when the optional JS is mounted)
copyir.com Refer to the option service manual (JS   copyir.com503) for details.
C0B80    Shift Motor malfunction (Only when the optional SF is mounted)
copyir.com Refer to the option service manual (SF   copyir.com501) for details.
C0F32    Faulty ATDC Sensor
copyir.com The measurement taken by the ATDC Sensor (UN1) at a time 2.0 sec. after the Main Motor (M1) has started turning is less than 5% (greater than 4.63 V).
copyir.com The measurement taken by the ATDC Sensor (UN1) at a time 2.0 sec. after the Main Motor (M1) has started turning is 19% or more (1.41 V or less).    1 Check to see if developer is available. 2 Check the ATDC Sensor connectors for proper connection and correct as necessary. 3 Change UN1. 4 Run ?gATDC Auto Adjust. 5 Change PWB   copyir.comA. 6 Change PU1.
C0F33    Improperly adjusted ATDC Sensor
copyir.com The adjustment of the ATDC control voltage is not completed within 1 sec. after sampling has started of the ATDC Sensor (UN1) as part of an operation of ATDC Sensor Automatic Adjustment.
copyir.com The ATDC Sensor control voltage falls outside the range of 5.39 V to 8.15 V during an operation of ATDC Sensor Automatic Adjustment.
C1038    Engine connection failure
Master Board (PWB   copyir.comA) to Control Board (PWB   copyir.comC/C) connection failure
copyir.com There is no acknowledge signal transmitted from the Master Board (PWB   copyir.comA) to Control Board (PWB   copyir.comC/C) for 1.5 sec. or more.
copyir.com An error command signal is transmitted from the Control Board (PWB   copyir.comC/C) to Master Board (PWB   copyir.comA).
copyir.com An error status signal is transmitted from the Master Board (PWB   copyir.comA) to Control Board (PWB   copyir.comC/C).    1 Turn OFF and ON the Power Switch. 2 Check the PWB   copyir.comA connectors for proper connection and correct as necessary. 3 Check the PWB   copyir.comC/C connectors for proper connection and correct as necessary. 4 Check for proper connection between PWB   copyir.comA and PWB   copyir.comC/C and correct as necessary. 5 Change PWB   copyir.comA. 6 Change PWB   copyir.comC/C.
C1200    Faulty ASIC/memory
ASIC/memory (for image and control) fault
A write or read error occurs with SRAM on the Control Board (PWB   copyir.comC/C).    1 Turn OFF and ON the Power Switch. 2 Check memory on PWB   copyir.comC/C for connection and correct as necessary. 3 Change PWB   copyir.comC/C.
C1300    Polygon Motor malfunction
copyir.comStartup failure
copyir.com Lock signal fault: Unstable after the first Lock signal has been detected
copyir.com Lock signal fault: Lock signal out   copyir.comof   copyir.comtiming    1 Turn OFF and ON the Power Switch. 2 Check for proper connection between the PH Unit and Master Board and correct as necessary. 3 Change the PH Unit. 4 Change PWB   copyir.comA.
C133B    Communication with option error
copyir.com It is not possible to communicate with the Printer Board within a predetermined period of time during a print cycle.
C133D    ROM check error
copyir.com An error is detected of the flash ROM chip on the Fax Board when the Power Switch is turned ON.
C13F0    Faulty HSYNC
Laser scanning system malfunction
copyir.com The SOS Sensor does not detect a rising edge of SOS within a given period of time after the Polygon Motor (M2) has started turning and a laser output has been started.
copyir.com The SOS Sensor detects no rising edges of SOS while VIA (image area control) is ON.    1 Turn OFF and ON the Power Switch. 2 Check for proper connection between the PH Unit and Master Board and correct as necessary. 3 Change the PH Unit. 4 Change PWB   copyir.comA.
C1468    Faulty Parameter Chip
Parameter Chip fault
copyir.com Data cannot be written in Parameter Chip.
copyir.com Data stored in Parameter Chip is wrong.    1 Turn OFF the Power Switch and unplug the power cord. Then, plug in the power cord and turn ON the Power Switch again. 2 Check Parameter Chip (U16) on PWB   copyir.comC/C for proper connection and correct as necessary. 3 Change PWB   copyir.comA. 4 Change Parameter Chip.
C14A3    IR fluorescent lamp fault
The Exposure Lamp (LA2) of the Scanner fails to turn ON.
copyir.com The intensity of the Exposure Lamp is a predetermined value or less during shading and re   copyir.comshading.    1 Check that the Exposure Lamp (LA2) turns ON when the Power Switch is turned ON and correct or replace as necessary. 2 Check connectors on PU2 for proper connection and correct as necessary. 3 Check connectors on PWB   copyir.comJ for proper connection and correct as necessary. 4 Change PWB   copyir.comC/C.