کونیکا مینولتا Konica-Minolta bizhub 223
C0001 LCT Communication Failure
– Due to a software malfunction, etc copyir.com, the time on the watchdog timer has run out and a reset is performed copyir.com
C0202 Tray 1 Elevator Failure
– The Lift-Up Sensor is not unblocked even after the set period of time has elapsed after the paper lift up operation for the drawer has begun copyir.com 1 Check the motor and sensor connectors for proper connection, and correct as necessary copyir.com 2 Check the connector of each motor for proper drive coupling, and correct as necessary copyir.com 3 Check the PU1 connector for proper connection and correct as necessary copyir.com 4 PC6 I/O check copyir.com 5 PC12 I/O check copyir.com 6 PC114-PF I/O check copyir.com 7 PC123-PF I/O check copyir.com 8 M7 operation check copyir.com 9 M8 operation check copyir.com 10 M124-PF operation check copyir.com 11 M125-PF operation check copyir.com 12 Change PWB-A copyir.com 13 Change PWB-C2 copyir.com 14 Change PU1 copyir.com
C0204 Tray 2 Elevator Failure
– The Lift-Up Sensor is not unblocked even after the set period of time has elapsed after the paper lift up operation for the drawer has begun copyir.com 1 Check the motor and sensor connectors for proper connection, and correct as necessary copyir.com 2 Check the connector of each motor for proper drive coupling, and correct as necessary copyir.com 3 Check the PU1 connector for proper connection and correct as necessary copyir.com 4 PC6 I/O check copyir.com 5 PC12 I/O check copyir.com 6 PC114-PF I/O check copyir.com 7 PC123-PF I/O check copyir.com 8 M7 operation check copyir.com 9 M8 operation check copyir.com 10 M124-PF operation check copyir.com 11 M125-PF operation check copyir.com 12 Change PWB-A copyir.com 13 Change PWB-C2 copyir.com 14 Change PU1 copyir.com
C0206 Tray 3 Elevator Failure
– The Lift-Up Sensor is not unblocked even after the set period of time has elapsed after the paper lift up operation for the drawer has begun copyir.com 1 Check the motor and sensor connectors for proper connection, and correct as necessary copyir.com 2 Check the connector of each motor for proper drive coupling, and correct as necessary copyir.com 3 Check the PU1 connector for proper connection and correct as necessary copyir.com 4 PC6 I/O check copyir.com 5 PC12 I/O check copyir.com 6 PC114-PF I/O check copyir.com 7 PC123-PF I/O check copyir.com 8 M7 operation check copyir.com 9 M8 operation check copyir.com 10 M124-PF operation check copyir.com 11 M125-PF operation check copyir.com 12 Change PWB-A copyir.com 13 Change PWB-C2 copyir.com 14 Change PU1 copyir.com
C0208 Tray 4 Elevator Failure
– The Lift-Up Sensor is not unblocked even after the set period of time has elapsed after the paper lift up operation for the drawer has begun copyir.com 1 Check the motor and sensor connectors for proper connection, and correct as necessary copyir.com 2 Check the connector of each motor for proper drive coupling, and correct as necessary copyir.com 3 Check the PU1 connector for proper connection and correct as necessary copyir.com 4 PC6 I/O check copyir.com 5 PC12 I/O check copyir.com 6 PC114-PF I/O check copyir.com 7 PC123-PF I/O check copyir.com 8 M7 operation check copyir.com 9 M8 operation check copyir.com 10 M124-PF operation check copyir.com 11 M125-PF operation check copyir.com 12 Change PWB-A copyir.com 13 Change PWB-C2 copyir.com 14 Change PU1 copyir.com
C0209 LCT Elevator Motor Failure
– The Elevator Motor Pulse Sensor (PC10-LCT) cannot detect both edges of H/L even after the set period of time has elapsed while the Elevator Motor (M5-LCT) is turning backward/forward (raise/lower) copyir.com
C0211 Bypass Lifting Motion Failure
– The Bypass Lift Sensor (PC29) is not blocked or unblocked even after the set period of time has elapsed after the Bypass Pick-Up Solenoid (SL3) is energized after the manual feed paper take-up operation has begun copyir.com 1 Check the SL3 connector for proper connection and correct as necessary copyir.com 2 Check cam position copyir.com copyir.com 3 PC29 I/O check PWB-A copyir.com 4 SL3 operation check copyir.com 5 Change PWB-A copyir.com
C0212 LCT Ejection Failure
– See PC-407 sevice manual
C0213 LCT Shift Gate Malfunction
– See PC-407 sevice manual
C0214 LCT Shifting Failure
– See PC-407 sevice manual
C0215 LCT Shift Motor Malfunction
– See PC-407 sevice manual
C0701 Manual Paper Size Detection Adjustment Failure
– The control value of the Manual Paper Size Detection Unit does not fall within the specified range when an adjustment is made of manual paper size detection copyir.com 1 Check the VR1 connector for proper connection and correct as necessary copyir.com 2 Readjust the VR1 copyir.com 3 Replace VR1 copyir.com 4 Change PWB-A copyir.com
C1080 Exit Option Communication Failure
– The connection status of a finishing option is changed after the copier has been turned on copyir.com 1 Turn OFF the Main Power Switch, wait for 10 sec copyir.com or more, and turn ON the Main Power Switch copyir.com 2 Check the PWB-A FN and the PWB-A for proper connection, and correct as necessary copyir.com 3 Change PWB-A FN copyir.com 4 Change PWB-A copyir.com
C1183 Elevator Motor Ascent/Descent Drive Failure
– See FS-530/ PU-501/ OT-602 service manual copyir.com
C1190 Aligning Plate 1 Drive Failure
– See FS-530/ PU-501/ OT-602 service manual copyir.com
C1191 Aligning Plate 2 Drive Failure
– See FS-530/ PU-501/ OT-602 service manual copyir.com
C11A0 Paper-Lifter Drive Failure
C11A1 Exit Roller Pressure/Retraction Failure
– See FS-530/ PU-501/ OT-602 service manual copyir.com
C11A2 Saddle Exit Roller Pressure/ Retraction Failure
-See SD-507 service manual copyir.com
C11A3 Shutter Drive Failure
– See FS-530/PU-501/OT-602 service manual copyir.com
C11A4 Saddle Exit Motor Failure
– See SD-507 service manual copyir.com
C11A5 Saddle In & Out Guide Motor Failure
– – See SD-507 service manual copyir.com
C11A6 Saddle Layable Guide Motor Drive Failure
– See SD-507 service manual copyir.com
C11B0 Staple Unit CD Drive Failure
– See FS-530/PU-501/OT-602 service manual copyir.com
C11B2 Staple Drive Failure
– See FS-530/PU-501/OT-602 service manual copyir.com
C11B5 Saddle Staple 1 Drive Failure
– See SD-507 service manual copyir.com
C11B6 Saddle Staple 2 Drive Failure
– See SD-507 service manual copyir.com
C11C0 Punch Cam Motor Unit Failure
– See FS-530/PU-501/OT-602 service manual copyir.com
C11D0 Crease Motor Drive Failure
– See SD-507 service manual copyir.com
C2211 IU Motor Failure
– The IU Motor Lock signal remains set to H for a set period of time while the IU Motor is turning copyir.com
– The IU Motor Lock signal remains set to L for a set period of time while the IU Motor remains stopped copyir.com 1 Check the M2 connector for proper connection and correct as necessary copyir.com 2 Check the M2 for proper drive coupling, and correct as necessary copyir.com 3 Check the PWB-A connector for proper connection and correct as necessary copyir.com 4 M2 operation check PWB-A PJ28A-11 (REM) M-4 5 Change PWB-A copyir.com 6 Change PU1 copyir.com
C2351 Toner Suction Fan Motor Failure
– The Toner Suction Fan Motor Lock signal remains set to H for a set period of time while the Toner Suction Fan Motor is turning copyir.com
– The Toner Suction Fan Motor Lock signal remains set to L for a set period of time while the Toner Suction Fan Motor remains stopped copyir.com 1 Check the M11 connector for proper connection and correct as necessary copyir.com 2 Check the fan for possible overload, and correct as necessary copyir.com 3 Check the PWB-A connector for proper connection and correct as necessary copyir.com 4 M11 operation check PWB-A PJ5A-13 (REM) D-14 5 Change PWB-A copyir.com 6 Change PU1 copyir.com
C2431 IU Fuse Blowing Failure
– The fuse is not blown even after the lapse of a predetermined period of time copyir.com 1 Check the UN2 connector for proper connection and correct as necessary copyir.com 2 Remove the Developing Unit from the IU, and then replace UN2 copyir.com 3 Run F8 copyir.com 4 Change PWB-A copyir.com 5 Change PU1N copyir.com
C2557 ATDC Sensor Failure
– The scanning value of the ATDC Sensor is less than 7 % while the IU Motor is turning copyir.com
– The scanning value of the ATDC Sensor is more than 19 % while the IU Motor is turning copyir.com 1 Check the UN2 connector for proper connection and correct as necessary copyir.com 2 Remove the Developing Unit from the IU, and then replace UN2 copyir.com 3 Run F8 copyir.com 4 Change PWB-A copyir.com 5 Change PU1N copyir.com
C255C ATDC Adjustment Failure
– The adjustment of the ATDC control voltage could not be completed in the set period of time when function F8 is run copyir.com
– The ATDC control voltage was not within the range of 5 copyir.com39 V to 8 copyir.com15 V when function F8 is run copyir.com 1 Check the UN2 connector for proper connection and correct as necessary copyir.com 2 Remove the Developing Unit from the IU, and then replace UN2 copyir.com 3 Run F8 copyir.com 4 Change PWB-A copyir.com 5 Change PU1N copyir.com
C2654 EEPROM Failure
– An EEPROM where no initial data is written is detected 1 Disconnect and then connect the power cord copyir.com Turn OFF the Main Power Switch, wait for 10 sec copyir.com or more, and turn ON the Main Power Switch copyir.com 2 Check the EEPROM on the Mechanical Control Board for proper connection, and correct as necessary copyir.com 3 Change PWB-A copyir.com 4 Change EEPROM copyir.com
C2702 Abnormal Image Transfer Voltage
– The image transfer voltage exceeds 100 V for the set period of time while the IU Motor remains stopped copyir.com 1 Check the installation of the Transfer Roller copyir.com 2 Change HV1
C3451 Fusing Warm-Up Failure (Main)
– The Fusing Roller Thermistor does not detect the required temperature within 30 sec copyir.com after a warmup cycle has begun; therefore, the copier does not complete the warm-up cycle copyir.com
– The temperature of the Fusing Rollers does not reach the required level even after the set period of time has elapsed during a warm-up cycle copyir.com 1 Check that the H1 comes on when the Main Power Switch is set to ON, and correct or replace as necessary copyir.com 2 Check that the H2 comes on when the Main Power Switch is set to ON, and correct or replace as necessary copyir.com 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary copyir.com 4 Check the operation of the TH1 copyir.com Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity copyir.com 5 Check the operation of the TH2 copyir.com Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity copyir.com 6 Check the continuity of the H1 copyir.com Correct or replace as necessary copyir.com 7 Check the continuity of the H2 copyir.com Correct or replace as necessary copyir.com 8 Change PU1 copyir.com 9 Change PWB-A copyir.com
C3452 Fusing Warm-Up Failure (Sub)
– The Fusing Roller Sub Thermistor does not detect the required temperature within 30 sec copyir.com after a warm-up cycle has begun; therefore, the copier does not complete the warm-up cycle copyir.com
– The temperature of the Fusing Rollers does not reach the required level even after the set period of time has elapsed during a warm-up cycle copyir.com 1 Check that the H1 comes on when the Main Power Switch is set to ON, and correct or replace as necessary copyir.com 2 Check that the H2 comes on when the Main Power Switch is set to ON, and correct or replace as necessary copyir.com 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary copyir.com 4 Check the operation of the TH1 copyir.com Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity copyir.com 5 Check the operation of the TH2 copyir.com Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity copyir.com 6 Check the continuity of the H1 copyir.com Correct or replace as necessary copyir.com 7 Check the continuity of the H2 copyir.com Correct or replace as necessary copyir.com 8 Change PU1 copyir.com 9 Change PWB-A copyir.com
C3751 High Fuser Temperature Failure (Main)
– The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature above 240 °C when the Main Power Switch is set to ON copyir.com 1 Check that the H1 comes on when the Main Power Switch is set to ON, and correct or replace as necessary copyir.com 2 Check that the H2 comes on when the Main Power Switch is set to ON, and correct or replace as necessary copyir.com 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary copyir.com 4 Check the operation of the TH1 copyir.com Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity copyir.com 5 Check the operation of the TH2 copyir.com Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity copyir.com 6 Check the continuity of the H1 copyir.com Correct or replace as necessary copyir.com 7 Check the continuity of the H2 copyir.com Correct or replace as necessary copyir.com 8 Change PU1 copyir.com 9 Change PWB-A copyir.com
C3752 High Fuser Temperature Failure (Sub)
– The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature above 240 °C when the Main Power Switch is set to ON copyir.com 1 Check that the H1 comes on when the Main Power Switch is set to ON, and correct or replace as necessary copyir.com 2 Check that the H2 comes on when the Main Power Switch is set to ON, and correct or replace as necessary copyir.com 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary copyir.com 4 Check the operation of the TH1 copyir.com Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity copyir.com 5 Check the operation of the TH2 copyir.com Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity copyir.com 6 Check the continuity of the H1 copyir.com Correct or replace as necessary copyir.com 7 Check the continuity of the H2 copyir.com Correct or replace as necessary copyir.com 8 Change PU1 copyir.com 9 Change PWB-A copyir.com
C3851 Low Fuser Temperature Failure (Main)
– The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below 105 °C during standby copyir.com
– The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below 105 °C during printing copyir.com 1 Check that the H1 comes on when the Right-Side Door is opened, then closed, and correct or replace as necessary copyir.com 2 Check that the H2 comes on when the Right-Side Door is opened, then closed, and correct or replace as necessary copyir.com 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary copyir.com 4 Check the operation of the TH1 copyir.com Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity copyir.com 5 Check the operation of the TH2 copyir.com Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity copyir.com 6 Check the continuity of the H1 copyir.com Correct or replace as necessary copyir.com 7 Check the continuity of the H2 copyir.com Correct or replace as necessary copyir.com 8 Change PU1 copyir.com 9 Change PWB-A copyir.com
C3852 Low Fuser Temperature Failure (Sub)
– The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below 105 °C during standby copyir.com
– The Fusing Roller Thermistor and Fusing Roller Sub Thermistor are detected to be at a temperature below 105 °C during printing copyir.com 1 Check that the H1 comes on when the Right-Side Door is opened, then closed, and correct or replace as necessary copyir.com 2 Check that the H2 comes on when the Right-Side Door is opened, then closed, and correct or replace as necessary copyir.com 3 Check the installation of the TH1 and the TH2, and correct or clean as necessary copyir.com 4 Check the operation of the TH1 copyir.com Remove CN80 (4P), and then check that the resistance across CN80-2 and -3 on the Thermistor is infinity copyir.com 5 Check the operation of the TH2 copyir.com Remove CN81 (4P), and then check that the resistance across CN81-2 and -3 on the Thermistor is infinity copyir.com 6 Check the continuity of the H1 copyir.com Correct or replace as necessary copyir.com 7 Check the continuity of the H2 copyir.com Correct or replace as necessary copyir.com 8 Change PU1 copyir.com 9 Change PWB-A copyir.com
C4001 Main body Communication Failure
Communications with the Mechanical Control Board and the MFBS Board/MFBS2 Board fail copyir.com 1 Check the MFBS/MFBS2 connector for proper connection, and correct as necessary copyir.com 2 Check the PWB-A connector for proper connection, and correct as necessary copyir.com 3 Check the flat cable between MFBS/MFBS2 and PWB-A for proper connection, and correct as necessary copyir.com 4 Turn OFF the Main Power Switch, wait for 10 sec copyir.com or more, and turn ON the Main Power Switch copyir.com 5 Change MFBS/MFBS2 copyir.com 6 Change PWB-A copyir.com
C4002 HSYNC Detection Failure
– No SOS falling edges are detected within the set period of time after laser emission began while the Polygon Motor is turning copyir.com
– No SOS falling edges are detected while VIA remains ON copyir.com 1 Turn OFF the Main Power Switch, wait for 10 sec copyir.com or more, and turn ON the Main Power Switch copyir.com 2 Check the PH and the PWB-A connectors for proper connection, and correct as necessary copyir.com 3 Change PH copyir.com 4 Change PWB-A copyir.com
C4101 Polygon Motor Failure
– The Polygon Motor Lock signal could not be detected within the set period of time after the Polygon Motor is energized copyir.com (Faulty start detection)
– No First Lock signals are detected during the 1- second period that starts 1 second after a First Lock signal copyir.com (Faulty lock signal detection)
– The Polygon Motor Lock signal could not be detected after the set period of time has elapsed while the Polygon Motor is turning copyir.com (Out-of-timing lock detection)
– The Polygon Motor Lock signal is set to ON for longer than the set period of time while the Polygon Motor remains stopped copyir.com (Abnormal lock detection) 1 Check the PH connector for proper connection, and correct as necessary copyir.com 2 Change PH copyir.com 3 Change PWB-A copyir.com
C4721 Main Body G/A Communication Failure
– Communications with the gate array for expansion I/O (the IC mounted on the Mechanical Control Board) fail copyir.com 1 Turn OFF the Main Power Switch, wait for 10 sec copyir.com or more, and turn ON the Main Power Switch copyir.com 2 Check each control board and the PWB-A for proper connection, and correct as necessary copyir.com 3 Change PWB-A copyir.com
C5102 Main Motor Failure
– The Transport Motor Lock signal remains set to H for a set period of time while the Transport Motor is turning copyir.com 1 Check the M1 connector for proper connection, and correct as necessary copyir.com 2 Check the M1 for proper drive coupling, and correct as necessary copyir.com 3 Check the PWB-A connector for proper connection and correct as necessary copyir.com 4 M1 operation check PWB-A PJ28A-4 (REM) M-4 5 Change PWB-A copyir.com 6 Change PU1 copyir.com
C5351 Power Supply Cooling Fan Motor Failure
– The Power Supply Cooling Fan Motor Lock signal remains set to H for a set period of time while the Power Supply Cooling Fan Motor is turning copyir.com
– The Power Supply Cooling Fan Motor Lock signal remains set to L for a set period of time while the Power Supply Cooling Fan Motor remains stopped copyir.com 1 Check the M4 connectors for proper connection, and correct as necessary copyir.com 2 Check the fan for possible overload, and correct as necessary copyir.com 3 M4 operation check PWB-A PJ33A-1 (REM) D-5 4 Change PU1 copyir.com
C5352 Cooling Fan Motor Failure
– The Cooling Fan Motor Lock signal remains set to H for a set period of time while the Cooling Fan Motor is turning copyir.com
– The Cooling Fan Motor Lock signal remains set to L for a set period of time while the Cooling Fan Motor remains stopped 1 Check the M5 connectors for proper connection, and correct as necessary copyir.com 2 Check the fan for possible overload, and correct as necessary copyir.com 3 M5 operation check copyir.com 4 Change PWB-A copyir.com
C5353 IU Cooling Fan Motor Failure
– The IU Cooling Fan Motor Lock signal remains set to H for a set period of time while the IU Cooling Fan Motor is turning copyir.com
– The IU Cooling Fan Motor Lock signal remains set to L for a set period of time while the IU Cooling Fan Motor remains stopped copyir.com 1 Check the M6 connectors for proper connection, and correct as necessary copyir.com 2 Check the fan for possible overload, and correct as necessary copyir.com 3 M6 operation check copyir.com 4 Change PWB-A copyir.com
C7001 Engine connection error
– The system fails in checking initial engine connection when the Power Switch is turned ON copyir.com
– The system succeeded in checking initial connection when the Power Switch was turned ON; then it fails in rechecking initial connection through the execution of a software reset when a communications error occurs during operation copyir.com 1 Check the connection between Mechanical Control Board and BCRS Board copyir.com 2 Reset the malfunction and turn OFF and ON the Power Switch copyir.com 3 Change BCRS copyir.com 4 Change PWB-A copyir.com
C8301 ADF Fan Motor Failure
– See DF-620 service manual copyir.com
C9701 ADF Document Size Failure Adjustment
– See DF-620 service manual copyir.com
CA052 MIO Device Failure
– The MIO device does not operate properly 1 Turn OFF the Main Power Switch, wait for 10 sec copyir.com or more, and turn ON the Main Power Switch copyir.com 2 Check the BCRS connectors for proper connection, and correct as necessary copyir.com 3 Change BCRS copyir.com
CC153 Flash ROM Failure
– The Flash ROM data was determined to be faulty when the unit was turned on copyir.com 1 Turn OFF the Main Power Switch, wait for 10 sec copyir.com or more, and turn ON the Main Power Switch copyir.com 2 The firmware data is overwritten copyir.com 3 Change PWB-A copyir.com
CC155 Exit Option Flash ROM Failure
– See FS-530/PU-501/OT-602 service manual copyir.com
CD004 HDD error
– When error occurs during deletion of HDD data copyir.com 1 Turn OFF the Main Power Switch, wait for 10 sec copyir.com or more, and turn ON the Main Power Switch copyir.com 2 Check theHard Disk connector for proper connection and correct as necessary copyir.com 3 Reinstall the Hard Disk copyir.com 4 Change Hard Disk copyir.com 5 Change MFBS/MFBS2 copyir.com