کونیکا مینولتا Konica-Minolta bizhub 284e

ایرادات دستگاهای کونیکا مینولتا  براساس کد می باشد شرکت کپی ایران در نظر داردتمامی سرویس منالها و رفع ایرادادت را در اختیار شما عزیزان قرار دهد

 

 

C0002    Paper feed communication error
When the printer control board (PRCB) is receiving data, a communication error is detected    copyir.com    1 Turn OFF the main power switch, disconnect and then connect the power cord    copyir.com Wait for 10 sec    copyir.com or more after connect the power cord, and turn ON the main power switch    copyir.com 2 Rewrite the firmware    copyir.com 3 Replace PRCB    copyir.com
C0106    Tray 3/LCT paper feed motor turning at abnormal timing
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary    copyir.com • The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary    copyir.com    When PC-110 or PC-210 is installed: 1 Check the connector between M111-PCCB CN5 for proper connection and correct as necessary    copyir.com 2 Check the connector of M111 for proper drive coupling and correct as necessary    copyir.com 3 M111 operation check PCCB CN5-5 (CW/CCW) PC-110/PC-210 4-C    copyir.com 4 Replace M111    copyir.com 5 Replace PCCB    copyir.com
When PC-410 is installed: 1 Check the connector between M131-PCCB CN5 for proper connection and correct as necessary    copyir.com 2 Check the connector of M131 for proper drive coupling and correct as necessary    copyir.com 3 M131 operation check PCCB CN5-5 (CW/CCW) PC-410 5-J 4 Replace M131    copyir.com 5 Replace PCCB    copyir.com
C0107    Tray 3/LCT vertical transport motor turning at abnormal timing
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary    copyir.com • The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary    copyir.com    When PC-110 or PC-210 is installed: 1 Check the connector between M112-PCCB CN5 for proper connection and correct as necessary    copyir.com 2 Check the connector of M112 for proper drive coupling and correct as necessary    copyir.com 3 M112 operation check PCCB CN5-13 (CW/CCW) PC-110/PC-210 3 to 4-C    copyir.com 4 Replace M112    copyir.com 5 Replace PCCB    copyir.com
When PC-410 is installed: 1 Check the connector between M132-PCCB CN5 for proper connection and correct as necessary    copyir.com 2 Check the connector of M132 for proper drive coupling and correct as necessary    copyir.com 3 M132 operation check PCCB CN5-13 (CW/CCW) PC-410 4-J    copyir.com 4 Replace M132    copyir.com 5 Replace PCCB    copyir.com
C0108    Tray 4 paper feed motor turning at abnormal timing
<When PC-210 is installed> • The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary    copyir.com • The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary    copyir.com    1 Check the connector between M121-PCCB CN9 for proper connection and correct as necessary    copyir.com 2 Check the connector of M121 for proper drive coupling and correct as necessary    copyir.com 3 M121 operation check PCCB CN9-5 (CW/CCW) PC-210 6-K    copyir.com 4 Replace M121    copyir.com 5 Replace PCCB
C0109    Tray 4 vertical transport motor turning at abnormal timing
<When PC-210 is installed> • The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary    copyir.com • The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary    copyir.com    1 Check the connector between M122-PCCB CN9 for proper connection and correct as necessary    copyir.com 2 Check the connector of M122 for proper drive coupling and correct as necessary    copyir.com 3 M122 operation check PCCB CN9-13 (CW/CCW) PC-210 6-K    copyir.com 4 Replace M122    copyir.com 5 Replace PCCB    copyir.com
C0202    Tray 1 feeder up/down abnormality
The tray 1 upper limit sensor (PS22) is not blocked even after the lapse of a given period of time after the lifting motion has been started    copyir.com    1 Check the connector between M12-PRCB CN25 for proper connection and correct as necessary    copyir.com 2 Check the connector of M12 for proper drive coupling and correct as necessary    copyir.com 3 Check the connector between PS25-relay CN30- PRCB CN26 for proper connection and correct as necessary    copyir.com 4 PS25 I/O check, sensor check PRCB CN26-3 (ON)    copyir.com 5 M12 operation check PRCB CN25-5 (REM)    copyir.com 6 Replace M12    copyir.com 7 PRCB ICP5 conduction check    copyir.com 8 Replace PRCB    copyir.com
C0204    Tray 2 feeder up/down abnormality
The tray 2 upper limit sensor (PS22) is not blocked even after the lapse of a given period of time after the lifting motion has been started    copyir.com    1 Check the connector between M13-PRCB CN20 for proper connection and correct as necessary    copyir.com 2 Check the connector of M13 for proper drive coupling and correct as necessary    copyir.com 3 Check the connector between PS22-relay CN40- PRCB CN19 for proper connection and correct as necessary    copyir.com 4 PS22 I/O check, sensor check PRCB CN19-9 (ON)    copyir.com 5 M13 operation check PRCB CN20-5 (REM)    copyir.com 6 Replace M13    copyir.com 7 PRCB ICP4 conduction check    copyir.com 8 Replace PRCB    copyir.com
C0206    Tray 3 lift-up failure
The tray 3 upper limit sensor (PS116) is not blocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began    copyir.com    1 Check the connector between M113-PCCB CN6 for proper connection and correct as necessary    copyir.com 2 Check the connector of M113 for proper drive coupling and correct as necessary    copyir.com 3 Check the connector between PS116-relay CN24- PCCB CN4 for proper connection and correct as necessary    copyir.com 4 PS116 I/O check, sensor check PCCB CN4-3 (ON)    copyir.com 5 M113 operation check PCCB CN6-8 to 9    copyir.com 6 Replace M113    copyir.com 7 Replace PCCB    copyir.com 8 Replace MFPB    copyir.com
C0208    Tray 4 lift-up failure
The tray 4 upper limit sensor (PS126) is not blocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began    copyir.com    1 Check the connector between M123-PCCB CN8 for proper connection and correct as necessary    copyir.com 2 Check the connector of M123 for proper drive coupling and correct as necessary    copyir.com 3 Check the connector between PS126-relay CN47- PCCB CN7 for proper connection and correct as necessary    copyir.com 4 PS126 I/O check, sensor check PCCB CN7-3    copyir.com 5 M123 operation check PCCB CN8-8 to 9    copyir.com 6 Replace M123    copyir.com 7 Replace PCCB    copyir.com 8 Replace MFPB    copyir.com
C0210    LCT lift failure
• The main tray upper limit sensor (PS136) is not blocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began    copyir.com • The shifter stop / lower limit position sensor (PS138) is not unblocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began    copyir.com • The main tray upper limit sensor (PS136) is not blocked even after the set period of time has elapsed after the paper lift-up operating    copyir.com • The main tray upper limit sensor (PS136) is not unblocked even after the set period of time has elapsed after the paper lift-down operation began    copyir.com • The shifter stop / lower limit position sensor (PS138) is not blocked even after the set period of time has elapsed after the paper lift-down operation began    copyir.com    1 Check the connector between M134-PCCB CN10 for proper connection and correct as necessary    copyir.com 2 Check the connector of M134 for proper drive coupling and correct as necessary    copyir.com 3 Check the connector between PS136-relay CN1- PCCB CN4 for proper connection and correct as necessary    copyir.com 4 Check the connector between PS138-relay CN16- PCCB CN14 for proper connection and correct as necessary    copyir.com 5 PS136 I/O check, sensor check PCCB CN4-3 (ON) PC-410 8-J    copyir.com 6 PS138 I/O check, sensor check PCCB CN14-6 (ON) PC-410 4-J    copyir.com 7 M134 operation check PCCB CN10-1 to 2 PC-410 6-J    copyir.com 8 Replace M134    copyir.com 9 PCCB IC2 conduction check    copyir.com 10 Replace PCCB    copyir.com
C0211    Manual feed up/down abnormality
• Paper does not unblock the bypass lift-up position sensor (PS26) even after the transport motor (M1) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position    copyir.com • The bypass lift-up position sensor (PS26) is not blocked even after the transport motor (M1) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position    copyir.com    1 Check the connector between M1-PRCB CN31 for proper connection and correct as necessary    copyir.com 2 Check the connector of M1 for proper drive coupling and correct as necessary    copyir.com 3 Check the connector between PS26-relay CN19- PRCB CN27 for proper connection and correct as necessary    copyir.com 4 Check the connector between SD1-relay CN21-relay CN19-PRCB CN27 for proper connection and correct as necessary    copyir.com 5 PS26 I/O check, sensor check PRCB CN27-13 (ON) 4-C    copyir.com 6 SD1 operation check PRCB CN27-10 (ON) 4-C 7    copyir.com M1 operation check PRCB CN31-2 (REM) PRCB CN31-5 (LOCK)    copyir.com 8 Replace M1    copyir.com 9 PRCB ICP5 conduction check    copyir.com 10 Replace PRCB    copyir.com
C0214    LCT shift failure
• The shifter stop / lower limit position sensor (PS138) is not blocked even after the set period of time has elapsed after the shift operation began (shift to the right)    copyir.com • The shifter home sensor (PS139) is not unblocked even after the set period of time has elapsed after the shift operation began (shift to the right)    copyir.com • The shifter stop / lower limit position sensor (PS138) is not unblocked even after the set period of time has elapsed after the return operation began (shift to the left)    copyir.com • The shifter home sensor (PS139) is not blocked even after the set period of time has elapsed after the return operation began (shift to the left)    copyir.com    1 Check the connector between M133-PCCB CN10 for proper connection and correct as necessary    copyir.com 2 Check the connector of M133 for proper drive coupling and correct as necessary    copyir.com 3 Check the connector between PS138-relay CN16- PCCB CN14 for proper connection and correct as necessary    copyir.com 4 Check the connector between PS139-relay CN16- PCCB CN14for proper connection and correct as necessary    copyir.com 5 PS138 I/O check, sensor check PCCB CN14-6 (ON) PC-410 4-J    copyir.com 6 PS139 I/O check, sensor check PCCB CN14-3 (ON) PC-410 4-J    copyir.com 7 M133 operation check PCCB CN10-3 to 4 PC-410 6-J    copyir.com 8 Replace M133    copyir.com 9 PCCB IC2 conduction check    copyir.com 10 Replace PCCB    copyir.com
C1004    FNS communication error
<When FS-533 or FS-534 is installed> When the FS control board (FSCB) is receiving data, a communication error is detected    copyir.com
<When JS-506 is installed> When the JS control board (JSCB) is receiving data, a communication error is detectedce M121    copyir.com    1 Turn OFF the main power switch, disconnect and then connect the power cord    copyir.com Wait for 10 sec    copyir.com or more after connect the power cord, and turn ON the main power switch    copyir.com 2 Rewrite the firmware    copyir.com 3 Replace FSCB (FS-533/FS-534) When JS-506 is installed Step Action Control signal Location of electrical components 1 Turn OFF the main power switch, disconnect and then connect the power cord    copyir.com Wait for 10 sec    copyir.com or more after connect the power cord, and turn ON the main power switch    copyir.com 2 Rewrite the firmware    copyir.com 3 Replace JSCB    copyir.com
C1081    SD communication error
<When FS-534+SD-511 is installed> When a communication error is detected between the FS control board (FSCB) and the SD control board (SDDB)    copyir.com    1 Turn OFF the main power switch, disconnect and then connect the power cord    copyir.com Wait for 10 sec    copyir.com or more after connect the power cord, and turn ON the main power switch    copyir.com 2 Rewrite the firmware    copyir.com 3 Replace SDDB    copyir.com 4 Replace FSCB    copyir.com
C1102    Main tray up/down motor’s drive malfunction
<When FS-533 is installed> • While the exit tray is being lifted, the stapler movement motor (M107) is not unblocked after the set period of time has elapsed after the tray lift up motor (M109) is turned ON    copyir.com • While the exit tray is being lowered, the stapler movement motor (M107) is not blocked after the set period of time has elapsed after the tray lift up motor (M109) is turned ON
<When FS-534 is installed> • While the exit tray is being lifted, the main tray upper position sensor (PS26/PS27) is not blocked and the main tray upper position detect switch (SW2) is not turned ON, even after the main tray up/down motor (M11) turns by the set number of times    copyir.com • While the exit tray is being lowered, the main tray full detection sensor (PS29) is not blocked after the set period of time has elapsed after the main tray up/down motor (M11) is turned ON    copyir.comc    When FS-533 is installed: 1 Check the connector between M109-FSCB CN108 for proper connection and correct as necessary    copyir.com 2 Check the connector of M109 for proper drive coupling and correct as necessary    copyir.com 3 Check the connector between PS107-FSCB CN110 for proper connection and correct as necessary    copyir.com 4 PS107 I/O check, sensor check FSCB CN110 FS-533 7-D to E 5 M109 operation check FSCB CN108 FS-533 10-E    copyir.com 6 Replace M109    copyir.com 7 FSCB CP109 conduction check    copyir.com 8 Replace FSCB    copyir.com
When FS-534 is installed: 1 Check the motor and sensor connectors for proper connection, and correct as necessary    copyir.com 2 Check the connector of M11 for proper drive coupling, and correct as necessary    copyir.com 3 PS26 I/O check, sensor check FSCB J14<A>-5 (ON) FS-534 2-C    copyir.com 4 PS27 I/O check, sensor check FSCB J14<B>-8 (ON) FS-534 3-C    copyir.com 5 PS29 I/O check, sensor check FSCB J14<A>-8 (ON) FS-534 4-C    copyir.com 6 SW2 operation check    copyir.com 7 M11 operation check FSCB J9<A>-9 to 10 FS-534 10-C to D    copyir.com 8 Replace M11    copyir.com 9 Replace FSCB    copyir.com
C1103    Alignment plate motor/Fr’s malfunction
<When FS-533 is installed> • The alignment plate home sensor/F (PS108) is not unblocked after the set period of time has elapsed after the plate drive starts from the home position    copyir.com • The alignment plate home sensor/F (PS108) is not blocked after the set period of time has elapsed after the alignment motor/F (M105) is turned ON to return the plate to the home position    copyir.com
<When FS-534 is installed> • The alignment plate/F home sensor (PS12) is not unblocked after the set period of time has elapsed after the plate drive starts from the home position    copyir.com • The alignment plate/F home sensor (PS12) is not blocked after the set period of time has elapsed after the alignment motor/front (M7) is turned ON to return the plate to the home position    copyir.com • The alignment plate/F does not reach the specified position within the set period of time    When FS-533 is installed: 1 Check the connector between M105-FSCB CN102 for proper connection and correct as necessary    copyir.com 2 Check the connector of M105 for proper drive coupling and correct as necessary    copyir.com 3 Check the connector between PS108-FSCB CN102 for proper connection and correct as necessary    copyir.com 4 PS108 I/O check, sensor check FSCB CN102 FS-533 7-J    copyir.com 5 M105 operation check FSCB CN102 FS-533 7-J    copyir.com 6 Replace M105    copyir.com 7 FSCB CP105 conduction check    copyir.com 8 Replace FSCB    copyir.com
When FS-534 is installed: 1 Check the connector between M7-FSCB J4 for proper connection and correct as necessary    copyir.com 2 Check the connector of M7 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS12-FSCB J4 for proper connection and correct as necessary    copyir.com 4 PS12 I/O check, sensor check FSCB J4<B>-4 (ON) FS-534 13-C    copyir.com 5 M7 operation check FSCB J4<A>-5 to 8 FS-534 11-C to D    copyir.com 6 Replace M7    copyir.com 7 Replace FSCB    copyir.com
C1105    Bundle eject motor’s drive malfunction
<When FS-534 is installed> • The gripper home position sensor (PS18) does not block even after the set period of time has elapsed after the gripper position detection sensor (PS19) unblocked    copyir.com • The gripper position detection sensor (PS19) does not block even after the set period of time has elapsed after it unblock • The gripper position detection sensor (PS19) does not block even after the set period of time has elapsed after the gripper home position sensor (PS18) unblocked    copyir.com • The gripper home position sensor (PS18) does not block even after the set period of time has elapsed after the bundle eject motor (M10) unblocked    copyir.com • The gripper home position sensor (PS18) and the gripper position detection sensor (PS19) are blocked at the same time    copyir.com    1 Check the motor and sensor connectors for proper connection, and correct as necessary    copyir.com 2 Check the connector of M10 for proper drive coupling, and correct as necessary    copyir.com 3 PS18 I/O check, sensor check FSCB J13-13 (ON) FS-534 7-C    copyir.com 4 PS19 I/O check, sensor check FSCB J12-3 (ON) FS-534 7-C    copyir.com 5 M10 operation check FSCB J13-1 to 2 FS-534 8-C to D    copyir.com 6 Replace M10    copyir.com 7 Replace FSCB    copyir.com
C1106    Stapler movement motor’s malfunction
<When FS-533 is installed> • The stapler home sensor (PS110) is not unblocked after the laps of given time after it started operating from the home position    copyir.com • The stapler home sensor (PS110) is not unblocked after the laps of give time after the stapler movement motor (M107) turned ON when it returned to the home position    copyir.com
<When FS-534 is installed> • The stapler home position sensor (Rear) (PS23) is not blocked or unblocked even after the set period of time has elapsed after the side stapler movement motor (M13) turned ON    copyir.com • The stapler does not reach the specified position within the set period of time    copyir.com J    When FS-533 is installed: 1 Check the connector between M107-STREYB CN123 for proper connection, and correct as necessary    copyir.com 2 Check the connector of M107 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS110-FSCB CN110 for proper connection, and correct as necessary    copyir.com 4 PS110 I/O check, sensor check FSCB CN110 FS-533 8-D to E    copyir.com 5 M107 operation check STREYB CN123-5 to 8 FS-533 5-L    copyir.com 6 Replace M107    copyir.com 7 Replace STREYB    copyir.com 8 FSCB CP107 conduction check    copyir.com 9 Replace FSCB    copyir.com
When FS-534 is installed: 1 Check the connector between M13-relay CN3-FSCB J11 for proper connection, and correct as necessary    copyir.com 2 Check the connector of M13 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS23-relay CN3-FSCB J11 for proper connection, and correct as necessary    copyir.com 4 PS23 I/O check, sensor check FSCB J11<B>-3 (ON) FS-534 4-C    copyir.com 5 M13 operation check FSCB J11<A>-1 to 4 FS-534 4-C to D    copyir.com 6 Replace M13    copyir.com 7 Replace FSCB    copyir.com
C1109    Stapler motor’s drive malfunction
<When FS-533 is installed> The stapler home sensor (PS110) is not blocked even after the set period of time has elapsed after the stapler motor turned ON    copyir.com
<When FS-534 is installed> • The stapler home position sensor (Rear) (PS23) is not blocked or unblocked even after the set period of time has elapsed after the stapler motor (M14) turned ON    copyir.com • The stapler position sensor (Center) (PS24) is blocked, when the stapler motor (M14) is running    copyir.com    When FS-533 is installed: 1 Check the connector between the stapler unit- STREYB CN122 and CN123 for proper connection and correct as necessary    copyir.com 2 Check the connector of the stapler unit for proper drive coupling and correct as necessary    copyir.com 3 Check the connector between PS110-FSCB CN110 for proper connection and correct as necessary    copyir.com 4 PS110 I/O check, sensor check FSCB CN110 FS-533 8-D to E    copyir.com 5 Replace the stapler unit    copyir.com 6 Replace STREYB    copyir.com 7 Replace FSCB    copyir.com
When FS-534 is installed: 1 Check the connector between the stapler unit-relay CN4-FSCB J11 for proper connection and correct as necessary    copyir.com 2 Check the connector of the stapler unit for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS23-relay CN3-FSCB J11 for proper connection and correct as necessary    copyir.com 4 Check the connector between PS24-relay CN3-FSCB J11 for proper connection and correct as necessary    copyir.com 5 PS23 I/O check, sensor check FSCB J11<B>-3 (ON) FS-534 4-C    copyir.com 6 PS24 I/O check, sensor check FSCB J11<B>-6 (ON) FS-534 4 to 5-C    copyir.com 7 Replace the stapler unit    copyir.com 8 Replace FSCB    copyir.com
C1112    Stapler motor’s malfunction
<When FS-534+SD-511 is installed> • The stapler home sensor is not turned ON even after the set period of time has elapsed while the stapler motor is energized    copyir.com • The stapler home sensor is not turned OFF even after the set period of time has elapsed after the stapler home sensor is turned ON    copyir.com    1 Check the connector between the staple unit-SDDB J4 for proper connection and correct as necessary    copyir.com 2 Check the connector of the staple unit for proper drive coupling and correct as necessary    copyir.com 3 Replace the staple unit    copyir.com 4 Replace SDDB    copyir.com 5 Replace FSCB    copyir.com
C1113    Center-staple lead edge stopper motor malfunction
<When FS-534+SD-511 is installed> The stopper home sensor (PS6) is not blocked or unblocked even after the set period of time has elapsed after the stopper drive motor (M4) is turned ON    copyir.com    1 Check the connector between M4-SDDB J10 for proper connection and correct as necessary    copyir.com 2 Check the connector of M4 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS6-SDDB J10 for proper connection, and correct as necessary    copyir.com 4 PS6 I/O check, sensor check SDDB J10-5 (ON) SD-511 2-G    copyir.com 5 M4 operation check SDDB J10-6 to 9 SD-511 1 to 2-F to G    copyir.com 6 Replace M4    copyir.com 7 Replace SDDB    copyir.com 8 Replace FSCB    copyir.com
C1114    Center-staple front adjust drive motor malfunction
<When FS-534+SD-511 is installed> The alignment home sensor (PS4) is not blocked or unblocked even after the set period of time has elapsed after the alignment motor (M3) is turned ON    copyir.com    1 Check the connector between M3-relay CN10-SDDB J7 for proper connection and correct as necessary    copyir.com 2 Check the connector of M3 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS4-relay CN10-SDDB J7 for proper connection, and correct as necessary    copyir.com 4 PS4 I/O check, sensor check SDDB J7-6 (ON) SD-511 6-F    copyir.com 5 M3 operation check SDDB J7 7 to 10 SD-511 5-F to G    copyir.com 6 Replace M3    copyir.com 7 Replace SDDB    copyir.com 8 Replace FSCB    copyir.com
C1115    Center-staple knife drive motor malfunction
<When FS-534+SD-511 is installed> The center fold knife home sensor (PS8) is not blocked or unblocked even after the set period of time has elapsed after the center fold knife motor (M9) is turned ON    copyir.com    1 Check the connector between M9-SDDB J11 for proper connection and correct as necessary    copyir.com 2 Check the connector of M9 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS8-relay CN10-SDDB J7 for proper connection, and correct as necessary    copyir.com 4 PS8 I/O check, sensor check SDDB J7-3 (ON) SD-511 6-G    copyir.com 5 M9 operation check SDDB J11 11 to 20 SD-511 1 to 2-B    copyir.com 6 Replace M9    copyir.com 7 Replace SDDB    copyir.com 8 Replace FSCB    copyir.com
C1132    Punch drive motor’s malfunction
<When FS-533+PK-519 is installed> • The puncher drive cam sensor (PS203) or puncher home sensor (PS204) is not blocked or unblocked even after the set period of time has elapsed while the punch motor (M201) is energized    copyir.com • The punch motor sensor (PS202) does not turn ON after the punch motor (M201) stopped    copyir.com • The holes with other marketing area is set in [Service Mode] – [Finisher] – [Punch Option Setting]
<When FS-534+PK-520 is installed> The punch home sensor (PS1) is not blocked or unblocked even after the set period of time has elapsed while the punch drive motor (M1) is energized    copyir.com    When FS-533+PK-519 is installed: 1 Check the number of the holes in [Service Mode] – [Finisher] – [Punch Option Setting]    copyir.com 2 Check the connector between M201-PKCB CN203 for proper connection, and correct as necessary    copyir.com 3 Check the connector of M201 for proper drive coupling, and correct as necessary    copyir.com 4 Check the connector between PS202-PKCB CN204 for proper connection, and correct as necessary    copyir.com 5 Check the connector between PS203-PKCB CN204    copyir.com for proper connection, and correct as necessary    copyir.com 6 Check the connector between PS204-PKCB CN204 for proper connection, and correct as necessary    copyir.com 7 PS202 I/O check, sensor check PKCB CN204 FS-533 (PK-519) 5-C    copyir.com 8 PS203 I/O check, sensor check PKCB CN204 FS-533 (PK-519) 6-C    copyir.com 9 PS204 I/O check, sensor check PKCB CN204 FS-533 (PK-519) 6-C    copyir.com 10 M201 operation check PKCB CN203-1 to 2 FS-533 (PK-519) 4-C    copyir.com 11 Replace M201    copyir.com 12 PKCB F201 conduction check    copyir.com 13 Replace PKCB    copyir.com 14 Replace FSCB    copyir.com
When FS-534+PK-520 is installed: 1 Check the connector between M1-relay CN351-FSCB J7 for proper connection, and correct as necessary    copyir.com 2 Check the connector of M1 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS1-FSCB J7 for proper connection, and correct as necessary    copyir.com 4 PS1 I/O check, sensor check FSCB J7-5 (ON) FS-534 (PK-520) 7-K    copyir.com 5 M1 operation check FSCB J7 7 to 8 FS-534 (PK-520) 7-K 6 Replace M1    copyir.com 7 Replace FSCB    copyir.com
C1140    Alignment plate motor/Rr’s malfunction
<When FS-533 is installed> • The alignment plate home sensor/R (PS109) is not unblocked after the set period of time has elapsed after the plate drive starts from the home position    copyir.com • The alignment plate home sensor/R (PS109) is not blocked after the set period of time has elapsed when the plate returns to the home position    copyir.com
<When FS-534 is installed> The alignment plate/R home sensor (PS13) is not blocked or unblocked even after the set period of time has elapsed while the alignment motor/Rr (M8) is energized    copyir.com    When FS-533 is installed: 1 Check the connector between M106-FSCB CN102 for proper connection and correct as necessary    copyir.com 2 Check the connector of M106 for proper drive coupling and correct as necessary    copyir.com 3 Check the connector between PS109-relay CN106- FSCB CN102 for proper connection and correct as necessary    copyir.com 4 PS109 I/O check, sensor check FSCB CN102 FS-533 7-J 5 M106 operation check FSCB CN102 FS-533 8-J 6 Replace M106    copyir.com 7 FSCB CP105 conduction check    copyir.com 8 Replace FSCB    copyir.com
When FS-534 is installed: 1 Check the connector between M8-FSCB J12 for proper connection, and correct as necessary    copyir.com 2 Check the connector of M8 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS13-FSCB J9 for proper connection, and correct as necessary    copyir.com 4 PS13 I/O check, sensor check FSCB J9<B>-9 (ON) FS-534 9-C    copyir.com 5 M8 operation check FSCB J12-13 to 16 FS-534 5~6-C to D 6 Replace M8    copyir.com 7 Replace FSCB    copyir.com
C1141    Paddle motor’s drive malfunction
<When FS-534 is installed> The upper paddle homeposition detection sensor (PS14) is not blocked or unblocked even after the set period of time has elapsed while the FNS paddle motor (M5) is turning    copyir.com    1 Check the connector between M5-FSCB J4 for proper connection, and correct as necessary    copyir.com 2 Check the connector of M5 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS14-FSCB J4 for proper connection, and correct as necessary    copyir.com 4 PS14 I/O check, sensor check FSCB J4<B>-7 (ON) FS-534 13-C    copyir.com 5 M5 operation check FSCB J4<A>-5 to 8 FS-534 12-C to D    copyir.com 6 Replace M5    copyir.com 7 Replace FSCB    copyir.com
C1144    Pre-eject drive motor’s malfunction
<When FS-534 is installed> • The pre-eject home sensor (PS21) is not blocked or unblocked even after the set period of time has elapsed after the pre-eject drive motor (M9) is turned ON    copyir.com • The pre-eject away sensor (PS22) is not blocked or unblocked even after the set period of time has elapsed after the pre-eject drive motor (M9) is turned ON    copyir.comk    1 Check the connector between M9-relay CN7<A>- FSCB J13 for proper connection, and correct as necessary    copyir.com 2 Check the connector of M9 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS21-relay CN8-relay CN7<B>-FSCB J12 for proper connection, and correct as necessary    copyir.com 4 Check the connector between PS22-relay CN8-relay CN7<B>-FSCB J12 for proper connection, and correct as necessary    copyir.com 5 PS21 I/O check, sensor check FSCB J12-6 (ON) FS-534 6-C    copyir.com 6 PS22 I/O check, sensor check FSCB J12-9 (ON) FS-534 6-C    copyir.com 7 M9 operation check FSCB J13-3 to 4 FS-534 8-C to D    copyir.com 8 Replace M9    copyir.com 9 Replace FSCB    copyir.com
C1145    Trailing edge stopper motor’s malfunction
<When FS-534 is installed> The trailing edge stopper home position detection sensor (PS20) is not blocked or unblocked even after the set period of time has elapsed after the trailing edge stopper motor (M6) is turned ON    copyir.com    1 Check the connector between M6-FSCB J5 for proper connection, and correct as necessary    copyir.com 2 Check the connector of M6 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS20-relay CN22-FSCB J5 for proper connection, and correct as necessary    copyir.com 4 PS20 I/O check, sensor check FSCB J5-9 (ON) FS-534 9-K    copyir.com 5 M6 operation check FSCB J5-13 to 16 FS-534 9-K    copyir.com 6 Replace M6    copyir.com 7 Replace FSCB    copyir.com
C1156    Center-staple paddle roller motor malfunction (trailing edge)
<When FS-534+SD-511 is installed> The paddle home sensor (PS5) is not blocked or unblocked even after the set period of time has elapsed while the SD paddle motor (M7) is energized    copyir.com    1 Check the connector between M7-SDDB J8 for proper connection and correct as necessary    copyir.com 2 Check the connector of M7 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS5-SDDB J8 for proper connection and correct as necessary    copyir.com – – 5 PS5 I/O check, sensor check SDDB J8-3 (ON) SD-511 3 to 4-G    copyir.com 7 M7 operation check SDDB J8 4 to 7 SD-511 3-F to G    copyir.com 8 Replace M7    copyir.com 9 Replace SDDB    copyir.com 10 Replace FSCB    copyir.com
C1182    Shift motor drive malfunction
<When JS-506 is installed> • The tray shift home sensor (PS1) is not unblocked after the set period of time has elapsed after the tray shift motor (M1) is turned ON (start of moving to the home position    copyir.com) • The tray shift home sensor (PS1) is not blocked after the set period of time has elapsed after the tray shift motor (M1) is turned ON (start of moving to the shift position    copyir.com)    1 Check the connector between M1-JSCB CN208 for proper connection and correct as necessary    copyir.com 2 Check the connector of M1 for proper drive coupling, and correct as necessary    copyir.com – – 3 Check the connector between PS1-JSCB CN208 for proper connection and correct as necessary    copyir.com 4 PS1 I/O check, sensor check JSCB CN208-5 (ON) JS-506 5-C    copyir.com 5 M1 operation check JSCB CN208 1 (DRV) JS-506 4 to 5-C    copyir.com 6 Replace M1    copyir.com 7 JSCB ICP3 conduction check    copyir.com 8 Replace JSCB    copyir.com
C1184    Paper discharge control motor’s malfunction
<When FS-534 is installed> The paper delivery control sensor (PS28) is not blocked or unblocked even after the set period of time has elapsed while the paper receiving control motor (M12) is energized    copyir.com    1 Check the connector between M12-relay CN1-FRCB J14 for proper connection, and correct as necessary    copyir.com 2 Check the connector of M12 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS28-relay CN1-FRCB J14 for proper connection, and correct as necessary    copyir.com 4 PS28 I/O check, sensor check FSCB J14<B>-3 (ON) FS-534 2~3-C    copyir.com 5 M12 operation check FSCB J14<A>-9 to 12 FS-534 2-C to D    copyir.com 6 Replace M12    copyir.com 7 Replace FSCB    copyir.com
C1195    Paper discharge control motor’s malfunction
<When FS-534+SD-511 is installed> The curl cover detection sensor (PS2) is not blocked or unblocked even after the set period of time has elapsed after the paper discharge control motor (M2) is turned ON    copyir.com    1 Check the connector between M2-relay CN3-relay CN2-SDDB J5 for proper connection, and correct as necessary    copyir.com 2 Check the connector of M2 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS2-relay CN3-relay CN2-SDDB J5 for proper connection, and correct as necessary    copyir.com 4 PS2 I/O check, sensor check SDDB J5 3 (ON) SD-511 3-B 5 M2 operation check SDDB J5 4 to 7 SD-511 3-B    copyir.com 6 Replace M2    copyir.com 7 Replace SDDB    copyir.com 8 Replace FSCB    copyir.com
C1196    Center fold roller motor’s malfunction
<When FS-534+SD-511 is installed> The guide home sensor (PS7) is not blocked or unblocked even after the set period of time has elapsed after the center fold roller motor (M8) is turned ON    copyir.com    1 Check the connector between M8-SDDB J8 for proper connection, and correct as necessary    copyir.com 2 Check the connector of M8 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS7-SDDB J9 for proper connection, and correct as necessary    copyir.com 4 PS7 I/O check, sensor check SDDB J9-6 (ON) SD-511 4-G    copyir.com 5 M8 operation check SDDB J10 6 to 9 SD-511 1 to 2-F to G    copyir.com 6 Replace M8    copyir.com 7 Replace SDDB    copyir.com 8 Replace FSCB    copyir.com
C1197    Tri-folding guide motor’s malfunction
<When FS-534+SD-511 is installed> The tri-folding gate home sensor (PS11) is not blocked or unblocked even after the set period of time has elapsed while the tri-folding guide motor (M6) is energized    copyir.com    1 Check the connector between M6-SDDB J9 for proper connection, and correct as necessary    copyir.com – – 2 Check the connector of M6 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS11-SDDB J8 for proper connection, and correct as necessary    copyir.com 4 PS11 I/O check, sensor check SDDB J8-10 (ON) SD-511 3-G    copyir.com 5 M6 operation check SDDB J9 7 to 10 SD-511 4-F to G    copyir.com 6 Replace M6    copyir.com 7 Replace SDDB    copyir.com 8 Replace FSCB    copyir.com
C11A1    Exit roller pressure/ retraction malfunction
<When FS-533 is installed> The pick up roller position sensor (PS105) is turned neither ON nor OFF even after the set period of time has elapsed after the exit roller lift up motor (M104) is turned ON    copyir.com    1 Check the connector between M104-FSCB CN109 for proper connection and correct as necessary    copyir.com 2 Check the connector of M104 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS105-FSCB CN110 for proper connection and correct as necessary    copyir.com 4 PS105 I/O check, sensor check FSCB CN110 FS-533 7-D to E    copyir.com 5 M104 operation check FSCB CN109 FS-533 9-D to E    copyir.com 6 Replace M104    copyir.com 7 FSCB CP104 conduction check    copyir.com 8 Replace FSCB    copyir.com
C11A2    Accommodation roller pressure/ retraction malfunction
<When FS-534 is installed> The receiving roller retraction sensor (PS11) is not blocked or unblocked even after the set period of time has elapsed after the receiving roller retraction motor (M4) is turned ON    copyir.com    1 Check the connector between M4-FSCB J4 for proper connection and correct as necessary    copyir.com 2 Check the connector of M4 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS11-FSCB J4 for proper connection, and correct as necessary    copyir.com 4 PS11 I/O check, sensor check FSCB J4<B>-16 (ON) FS-534 13-C    copyir.com 5 M4 operation check FSCB J4<A>-1 to 4 FS-534 11-C to D    copyir.com 6 Replace M4    copyir.com 7 Replace FSCB    copyir.com
C11E1    Paper exit switching drive malfunction
<When FS-534 is installed> The exchange folded knife home position sensor (PS30) is not blocked or unblocked even after the set period of time has elapsed after the FNS entry transport motor (M2) is turned ON    copyir.com    1 Check the connector between M2-FSCB J9 for proper connection and correct as necessary    copyir.com 2 Check the connector of M2 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS30-FSCB J4 for proper connection, and correct as necessary    copyir.com 4 PS30 I/O check, sensor check FSCB J4<A>-15 (ON) FS-534 12-C    copyir.com 5 M2 operation check FSCB J9<A>-1 to 4 FS-534 10 to 11-B to C    copyir.com 6 Replace M2    copyir.com 7 Replace FSCB    copyir.com
C1402    FS nonvolatile memory error
<When FS-533 is installed> When the main power switch is turned ON, malfunctioning of the nonvolatile memory on the FS control board (FSCB) is detected    copyir.com    1 Disconnect and then connect the power cord    copyir.com Turn OFF the main power switch, wait for 10 sec    copyir.com or more, and turn ON the main power switch    copyir.com 2 Rewrite the firmware    copyir.com 3 Replace FSCB    copyir.com
C2355    Transfer belt cleaner cooling fan motor’s failure to turn
The fan lock signal remains HIGH for a predetermined continuous period of time while the fan is turning    copyir.com    1 Check the connector between FM2-relay CN115- PRCB CN13 for proper connection and correct as necessary    copyir.com 2 Check the fan for possible overload and correct as necessary    copyir.com 3 FM2 operation check PRCB CN13-8 (REM) PRCB CN13-10 (LOCK) 24-C    copyir.com 4 Replace FM2    copyir.com 5 PRCB ICP3 conduction check    copyir.com 6 Replace PRCB    copyir.com
C2414    Developing unit/K new article release
The status with the new unit is not cleared after the new developing unit is set    copyir.com    1 Reinstall developing unit    copyir.com 2 Check the connector between developing unit-FRB CN13, CN14, CN15, CN16 for proper connection and correct as necessary    copyir.com 3 Check the connector between FRB CN1, CN3-PRCB CN7, CN9 for proper connection and correct as necessary    copyir.com 4 Replace the developing unit    copyir.com 5 Replace FRB    copyir.com 6 Replace PRCB    copyir.com
C2557    Abnormally low toner density detected black TCR sensor
When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hopper    1 Perform image troubleshooting procedure if image density is low    copyir.com 2 Reinstall developing unit    copyir.com 3 Reinstall toner cartridge    copyir.com 4 Check the connector between developing unit-FRB CN13, CN14, CN15, CN16 for proper connection and correct as necessary    copyir.com 5 Check the connector between FRB CN1, CN3-PRCB CN7, CN9 for proper connection and correct as necessary    copyir.com 6 M10 operation check M10 PRCB CN14-13 to 16 20-C 7 M6, M7    copyir.com M8, M9 operation check PRCB CN14-13 to 16 (M6) PRCB CN14-9 to 12 (M7) PRCB CN14-5 to 8 (M8) PRCB CN14-1 to 4 (M9) 19 to 20-C    copyir.com 8 If the toner empty sensor and its surroundings inside the sub hopper are dirtied with toner, clean them    copyir.com 9 Replace the developing unit – – 10 Replace FRB    copyir.com 11 PRCB ICP21, ICP40, ICP41, ICP44, ICP46 conduction check    copyir.com 12 Replace PRCB    copyir.com
C2558    Abnormally high toner density detected black TCR sensor
The TC ratio of the toner determined by the toner replenishment control is detected to be the predetermined value or over for consecutive times    copyir.com    1 Reinstall developing unit    copyir.com 2 Reinstall toner cartridge    copyir.com 3 Check the connector between developing unit-FRB CN13, CN14, CN15, CN16, CN10 for proper connection and correct as necessary    copyir.com 4 Check the connector between FRB CN1, CN3-PRCB CN7, CN9 for proper connection and correct as necessary    copyir.com 5 Replace the developing unit    copyir.com 6 Replace FRB    copyir.com 7 Replace PRCB    copyir.com
C255C    Black TCR sensor adjustment failure
TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value    copyir.com    1 Reinstall developing unit    copyir.com 2 Check the connector between developing unit-FRB CN13, CN14, CN15, CN16 for proper connection and correct as necessary    copyir.com 3 Check the connector between FRB CN1, CN3-PRCB CN7, CN9 for proper connection and correct as necessary    copyir.com 4 M10 operation check PRCB CN14-17 to 20 20-C 5 M6, M7, M8, M9 operation check PRCB CN14-13 to 16 (M6) PRCB CN14-9 to 12 (M7) PRCB CN14-5 to 8 (M8) PRCB CN14-1 to 4 (M9) 19 to 20-C    copyir.com 6 Replace the developing unit    copyir.com 7 Replace FRB    copyir.com 8 PRCB ICP21, ICP40, ICP43, ICP44, ICP46 conduction check    copyir.com 9 Replace PRCB    copyir.com
C2564    Black TCR sensor failure
TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value    copyir.com    1 Reinstall developing unit    copyir.com 2 Check the connector between developing unit-FRB CN13, CN14, CN15, CN16 for proper connection and correct as necessary    copyir.com 3 Check the connector between FRB CN1, CN3-PRCB CN7, CN9 for proper connection and correct as necessary    copyir.com 4 Replace the developing unit    copyir.com 5 Replace FRB    copyir.com 6 Replace PRCB    copyir.com
C2650    Main backup media access error
• The re-written data, which has been read out, checked and founded as error, is read out again and found as error    copyir.com • The error was found when reading out the counter value    copyir.com • MFP detects that the SSD board is not mounted    copyir.com    1 Check the connector from SSDB to MFPB for proper connection and correct as necessary    copyir.com 2 Check the harness from MFPB to PRCB for proper connection and correct as necessary    copyir.com 3 Replace MFPB    copyir.com 4 Replace PRCB    copyir.com 4    copyir.com1    copyir.com Check that the trouble code “C4802” appears and then display service mode    copyir.com 4    copyir.com2    copyir.com Call the Enhanced Security to the screen    copyir.com 4    copyir.com3    copyir.com Touch [Engine Data Backup]    copyir.com 4    copyir.com4    copyir.com Touch [Engine Data Load mode], and press the Start key    copyir.com 4    copyir.com5    copyir.com Select [Yes], and press the Start key again    copyir.com 4    copyir.com6    copyir.com Check that the result “OK” appears    copyir.com 4    copyir.com7    copyir.com Turn OFF the main power switch and turn it ON again more than 10 seconds after    copyir.com 4    copyir.com8    copyir.com Update the PRCB firmware    copyir.com 4    copyir.com9    copyir.com Make the specified readjustments    copyir.com 5 If the above actions do not solve the problem, contact KMBT    copyir.com
C2A14    Drum unit/K new release failure
The status with the new unit is not cleared after the new drum unit is set    copyir.com    1 Clean the connection between the drum unit and the machine if dirty    copyir.com 2 Reinstall drum unit    copyir.com 3 Check the connector between drum unit-FRB CN12 for proper connection and correct as necessary    copyir.com 4 Check the connector between FRB CN1, CN3-PRCB CN7, CN9 for proper connection and correct as necessary    copyir.com 5 Replace the drum unit    copyir.com 6 Replace FRB    copyir.com 7 Replace PRCB    copyir.com
C3101    Fusing roller separation failure
• With the fusing roller being retracted, the fusing pressure home sensor (PS38) is not unblocked even after the specified period of time has passed after the fusing pressure motor (M11) started rotating    copyir.com • With the fusing roller being pressed, the fusing pressure home sensor (PS38) is not blocked even after the specified period of time has passed after the fusing pressure motor (M11) started rotating    copyir.com    1 Check the connector between M11-PRCB CN13 for proper connection and correct as necessary    copyir.com 2 Check the connector between fusing unit-relay CN98, CN99, CN104-PRCB CN5 for proper connection and correct as necessary    copyir.com 3 PS38 I/O check, sensor check PRCB CN5-12 (ON) 27 to 28-C    copyir.com 4 M11 operation check PRCB CN13-1 to 4 25-C    copyir.com 5 Replace M11    copyir.com 6 Replace the fusing unit    copyir.com 7 PRCB IC26 conduction check    copyir.com 8 Replace PRCB    copyir.com
C3201    Fusing motor failure to turn
The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary    copyir.com    1 Check the connector between M3-PRCB CN2 for proper connection and correct as necessary    copyir.com 2 Check the loading status of the fusing unit drive, and correct the error as necessary    copyir.com 3 M3 operation check PRCB CN2-9 (REM) PRCB CN2-12 (LOCK) 27-I to J    copyir.com 4 Replace M3    copyir.com 5 Replace PRCB    copyir.com
C3202    Fusing motor turning at abnormal timing
The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary    copyir.com    1 Check the connector between M3-PRCB CN2 for proper connection and correct as necessary    copyir.com 2 Check the loading status of the fusing unit drive, and correct the error as necessary    copyir.com 3 M3 operation check PRCB CN2-9 (REM) PRCB CN2-12 (LOCK) 27-I to J    copyir.com 4 Replace M3    copyir.com 5 Replace PRCB    copyir.com
C3302    Paper cooling fan failure to turn
The fan lock signal remains HIGH for a predetermined continuous period of time while the fan remains stationary    copyir.com    1 Check the connector between FM8-relay CN106- PRCB CN12 for proper connection and correct as necessary    copyir.com 2 Check the fan for possible overload and correct as necessary    copyir.com 3 FM8 operation check PRCB CN12-1 (REM) PRCB CN12-3 (LOCK) 26-C    copyir.com 4 Replace FM8    copyir.com 5 PRCB ICP3 conduction check    copyir.com 6 Replace PRCB    copyir.com
C3425    Fusing warm-up trouble
• Detected temperature of the heating roller temperature sensor (TEMS) does not go up a given range of temperature even after a lapse of given period of time at warm up    copyir.com • The warm-up is not completed even after the set period of time has elapsed after the warm-up is started    copyir.com • Less than the predetermined temperature of the heating roller temperature sensor (TEMS), even after a predetermined period of time after warm-up is complete    copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)    copyir.com 2 Check the open/close operation of the right door    copyir.com 3 Check the fusing unit, DCPU and PRCB for proper connection and correct or change as necessary    copyir.com 4 Replace the fusing unit    copyir.com 5 Replace PRCB    copyir.com 6 Replace DCPU    copyir.com
C3722    Fusing abnormally high temperature detection (Edge of the heating side)
Detected temperature of the heating roller thermistor/1 (TH1) goes beyond a given temperature for a given period of time consecutively    copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)    copyir.com 2 Check the open/close operation of the right door    copyir.com 3 Check the fusing unit and PRCB for proper connection and correct or change as necessary    copyir.com 4 Replace the fusing unit    copyir.com 5 Replace PRCB    copyir.com
C3725    Fusing abnormally high temperature detection (Main of the heating side)
• Detected temperature of the heating roller temperature sensor (TEMS) goes beyond a given temperature for a given period of time consecutively    copyir.com • The hard protector signal error is detected for a given period of time consecutively    copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)    copyir.com 2 Check the open/close operation of the right door    copyir.com 3 Check the fusing unit and PRCB for proper connection and correct or change as necessary    copyir.com 4 Replace the fusing unit    copyir.com 5 Replace PRCB    copyir.com
C3726    Fusing abnormally high temperature detection (Center of the heating side)
Detected temperature of the heating roller thermistor/2 (TH2) goes beyond a given temperature for a given period of time consecutively    copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)    copyir.com 2 Check the open/close operation of the right door    copyir.com 3 Check the fusing unit and PRCB for proper connection and correct or change as necessary    copyir.com 4 Replace the fusing unit    copyir.com 5 Replace PRCB    copyir.com
C3825    Fusing abnormally low temperature detection (Main of the heating roller)
The heating roller temperature sensor (TEMS) continues to detect a temperature lower than a predetermined one for a predetermined period of time    copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)    copyir.com 2 Check the open/close operation of the upper right door    copyir.com 3 Check the fusing unit and PRCB for proper connection and correct or change as necessary    copyir.com 4 Replace the fusing unit    copyir.com 5 PRCB ICP15 conduction check    copyir.com 6 Replace PRCB    copyir.com
C3826    Fusing abnormally low temperature detection (Center of the heating roller)
The heating roller thermistor/2 (TH2) continues to detect a temperature lower than a predetermined one for a predetermined period of time    copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)    copyir.com 2 Check the open/close operation of the upper right door    copyir.com 3 Check the fusing unit and PRCB for proper connection and correct or change as necessary    copyir.com 4 Replace the fusing unit    copyir.com 5 PRCB ICP15 conduction check    copyir.com 6 Replace PRCB    copyir.com
C3922    Fusing sensor wire breaks detection (Edge of the heating roller)
After a predetermined period of time after the warm-up stage is started, the heating roller thermistor/1 (TH1) voltage does not decrease by predetermined steps (temperature rise) within a predetermined period of time    copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)    copyir.com 2 Check the open/close operation of the upper right door    copyir.com 3 Check the fusing unit and PRCB for proper connection and correct or change as necessary    copyir.com 4 Replace the fusing unit    copyir.com 5 Replace PRCB    copyir.com
C3925    Fusing sensor wire breaks detection (Center of the heating roller)
After a predetermined period of time after the warm-up stage is started, the heating roller temperature sensor (TEMS) voltage does not increase by predetermined steps (temperature rise) within a predetermined period of time    copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)    copyir.com 2 Check the open/close operation of the upper right door    copyir.com 3 Check the fusing unit and PRCB for proper connection and correct or change as necessary    copyir.com 4 Replace the fusing unit    copyir.com 5 Replace PRCB    copyir.com
C3926    Fusing sensor wire breaks detection (Middle of the heating roller)
• After a predetermined period of time after the warm-up stage is started, the heating roller thermistor/2 (TH2) voltage does not decrease by predetermined steps (temperature rise) within a predetermined time    copyir.com • When a temperature detected by the heating roller thermister/1 (TH1) is compared with the temperature detected by the heating roller thermister/2 (TH2) to find out that the difference exceeded the predetermined temperature    copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)    copyir.com 2 Check the open/close operation of the upper right door    copyir.com 3 Check the fusing unit and PRCB for proper connection and correct or change as necessary    copyir.com 4 Replace the fusing unit    copyir.com 5 Replace PRCB    copyir.com
C4101    Polygon motor rotation trouble
• The polygon motor fails to turn stably even after the lapse of a given period of time after activating and changing rotation speed the polygon motor    copyir.com • Motor lock signal detects HIGH for a given period time consecutively during the polygon motor is rotating    copyir.com    1 Check the connector between PH unit-FRB CN17 for proper connection and correct as necessary    copyir.com 2 Replace the PH unit    copyir.com 3 FRB fuse conduction check 4 Replace FRB    copyir.com 5 Replace PRCB    copyir.com
C4501    Laser malfunction
• SOS signal is not detected even after the lapse of a given period of time after starting the laser output    copyir.com • SOS signal is not detected for a given period of time during printing or IDC sensor adjustment    copyir.com    1 Check the connector between PH unit-PRCB CN24 for proper connection and correct as necessary    copyir.com 2 Replace the PH unit    copyir.com 3 Replace PRCB    copyir.com
C4801    Main unit board failure
MFP detects simultaneous replacement of multiple boards    copyir.com    1 Reinstall the old PRCB    copyir.com 2 Back up data    copyir.com 1    copyir.com Call the Service Mode to the screen    copyir.com 2    copyir.com Call the Enhanced Security to the screen    copyir.com 3    copyir.com Touch [Engine Data Backup]    copyir.com 2    copyir.com Touch [Engine Data Save mode], and press the Start key    copyir.com 3    copyir.com Select [Yes], and press the Start key again    copyir.com 4    copyir.com Check that the result “OK” appears    copyir.com 3 Replace PRCB Turn OFF the main power switch and replace the current PRCB with a new one    copyir.com (When using a PRCB of another machine in service, be sure to use a PRCB installed in the same model    copyir.com) 4 Restore back up data    copyir.com 1    copyir.com Turn ON the main power switch    copyir.com 2    copyir.com Check that the trouble code “C4802” appears and then display service mode    copyir.com 3    copyir.com Call the Enhanced Security to the screen    copyir.com 4    copyir.com Touch [Engine Data Backup]    copyir.com 5    copyir.com Touch [Engine Data Load mode], and press the Start key    copyir.com 6    copyir.com Select [Yes], and press the Start key again    copyir.com 7    copyir.com Check that the result “OK” appears    copyir.com 8    copyir.com Turn OFF the main power switch and turn it ON again more than 10 seconds after    copyir.com 5 Update the PRCB firmware    copyir.com 6 If the above actions do not solve the problem, contact KMBT    copyir.com
C4802    Main unit backup data miscompare
The replacement of the printer control board is detected    copyir.com    1 1    copyir.com1    copyir.com Check that the trouble code “C4802” appears and then display service mode    copyir.com1    copyir.com 2    copyir.com Call the Enhanced Security to the screen    copyir.com 1    copyir.com3    copyir.com Touch [Engine Data Backup]    copyir.com 1    copyir.com4    copyir.com Touch [Engine Data Load mode], and press the Start key    copyir.com 1    copyir.com5    copyir.com Select [Yes], and press the Start key again    copyir.com 1    copyir.com6    copyir.com Check that the result “OK” appears    copyir.com 1    copyir.com7    copyir.com Turn OFF the main power switch and turn it ON again more than 10 seconds after    copyir.com 2 Update the PRCB firmware    copyir.com 3 If the above actions do not solve the problem, contact KMBT    copyir.com
C5102    Transport motor’s failure to turn
The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary    copyir.com    1 Check the connector between M1-PRCB CN31 for proper connection and correct as necessary    copyir.com 2 Check M1 for proper drive coupling and correct as necessary    copyir.com 3 M1 operation check PRCB CN31-2 (REM) PRCB CN31-5 (LOCK)    copyir.com 4 Replace M1    copyir.com 5 Replace PRCB    copyir.com
C5103    Transport motor’s turning at abnormal timing
The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary    copyir.com    1 Check the connector between M1-PRCB CN31 for proper connection and correct as necessary    copyir.com 2 Check M1 for proper drive coupling and correct as necessary    copyir.com 3 M1 operation check PRCB CN31-2 (REM) PRCB CN31-5 (LOCK)    copyir.com 4 Replace M1    copyir.com 5 Replace PRCB    copyir.com
C5351    Power supply cooling fan motor’s failure to turn
The fan lock signal remains HIGH for a predetermined continuous period of time while the fan remains stationary    copyir.com    1 Check the connector between FM1-relay CN26-PRCB CN18 for proper connection and correct as necessary    copyir.com 2 Check the fan for possible overload and correct as necessary    copyir.com 3 FM1 operation check PRCB CN18-13 (REM) PRCB CN18-15 (LOCK) 6-C    copyir.com 4 Replace FM1    copyir.com 5 PRCB ICP2 conduction check    copyir.com 6 Replace PRCB    copyir.com
C5354    Ozone fan’s failure to turn
The fan lock signal remains HIGH for a predetermined continuous period of time while the fan remains stationary    copyir.com    1 Check the connector between FM13-relay CN158- PRCB CN23 for proper connection and correct as necessary    copyir.com 2 Check the fan for possible overload and correct as necessary    copyir.com 3 FM13 operation check PRCB CN23-10 (REM) PRCB CN23-12 (LOCK) 5-C    copyir.com 4 Replace FM13    copyir.com 5 PRCB ICP19 conduction check    copyir.com 6 Replace PRCB    copyir.com
C5355    Toner bottle cooling fan’s failure to turn
The fan lock signal remains HIGH for a predetermined continuous period of time while the fan remains stationary    copyir.com    1 Check the connector between FM4-relay CN157- PRCB CN34 for proper connection and correct as necessary    copyir.com 2 Check the fan for possible overload and correct as necessary    copyir.com 3 FM4 operation check PRCB CN34-1 (REM) PRCB CN34-3 (LOCK) 27-C    copyir.com 4 Replace FM4    copyir.com 5 PRCB ICP18 conduction check    copyir.com 6 Replace PRCB    copyir.com
C5370    Rear side cooling fan’s failure to turn
The fan lock signal remains HIGH for a predetermined continuous period of time while the fan remains stationary    copyir.com    1 Check the connector between FM3-MFPB PJ26 for proper connection and correct as necessary    copyir.com 2 Check the fan for possible overload and correct as necessary    copyir.com 3 FM3 operation check MFPB PJ26 (LOCK) 7-P    copyir.com 4 Replace FM3    copyir.com 5 Replace MFPB    copyir.com
C5372    MFP control board CPU temperature failure
Temperature failure of CPU on the MFP board was detected    copyir.com    1 Reboot the machine    copyir.com 2 Check the fan connector for proper connection and correct as necessary    copyir.com 3 Check the fan for possible overload and correct as necessary    copyir.com 4 Fan motor operation check    copyir.com 5 Replace MFPB    copyir.com
C5501    AC signal abnormality
The zero cross signal is not input during fusing phase control    copyir.com    1 Check the fusing unit for correct installation (whether it is secured in position)    copyir.com 2 Check the fusing unit, DCPU and PRCB for proper connection and correct or change as necessary    copyir.com 3 Replace fusing unit    copyir.com 4 Replace PRCB    copyir.com 5 Replace DCPU    copyir.com
C5601    Engine control malfunction
Engine control malfunction is detected with port monitor control    copyir.com    1 Check the connectors on the PRCB for proper connection and correct or change as necessary    copyir.com 2 Rewrite the firmware    copyir.com 3 Replace PRCB    copyir.com
C6001    DF related configuration error 1
Inconsistency in the configuration with the installed DF is detected on the main body    copyir.com    1 Check the type of the installed DF and replace it if it is a wrong one    copyir.com 2 Check to see if the correct firmware is installed and rewrite with the correct one as necessary    copyir.com 3 Correct the harness connection between DFCB and DSIPB if faulty    copyir.com 4 Correct the harness connection between DSIPB and MFPB if faulty    copyir.com 5 Replace DFCB    copyir.com 6 Replace DSIPB    copyir.com 7 Replace MFPB    copyir.com
C6002    DF related configuration error 2
Inconsistency in the configuration with the installed DF is detected on the DF    copyir.com    1 Check the type of the installed DF and replace it if it is a wrong one    copyir.com 2 Correct the harness connection between DFCB and DSIPB if faulty    copyir.com 3 Check the connectors of the dual scan image processing board (DSIPB) for proper connection, and correct as necessary    copyir.com (Direction of the point of contact and connection state of the flat cable in particular)
C6102    Drive system home sensor malfunction
• The scanner home sensor (PS201) is unable to detect the scanner located at its home position    copyir.com • The scanner home sensor (PS201) is unable to detect a scanner even when the scanner motor has been driven to move the scanner over the maximum travelling distance    copyir.com • The scanner home sensor (PS201) detects the scanner when the scanner has moved the maximum travelling distance from the position, at which it blocks the scanner home sensor (PS201)    copyir.com    1 Correct or change the scanner drive (pulley, gear, belt) if it is faulty    copyir.com 2 Correct the scanner motor set screw if loose    copyir.com 3 Adjust [Image Position Leading Edge] and [Feed Direction Adjustment]    copyir.com 4 Check the connector between M201-SCDB PJ4 for proper connection and correct as necessary    copyir.com 5 Check the connector between PS201-SCDB PJ6 for proper connection and correct as necessary    copyir.com 6 Check the connector between SCDB PJ2-PRCB CN43 for proper connection and correct as necessary    copyir.com 7 PS201 I/O check, sensor check SCDB PJ6-3 (ON) 25-P    copyir.com 8 M201 operation check SCDB PJ4-1 to 4 26-P    copyir.com 9 Replace SCDB    copyir.com 10 Replace PRCB    copyir.com
C6103    Slider over running
The scanner home sensor (PS201) detects the scanner at its home position during a period of time that begins with the time when a prescan command and a scan preparation command are executed and ends when a home return command is executed    copyir.com    1 Correct or change the scanner drive (pulley, gear, belt) if it is faulty    copyir.com 2 Correct the scanner motor set screw if loose    copyir.com 3 Adjust [Image Position Leading Edge] and [Feed Direction Adjustment]    copyir.com 4 Check the connector between M201-SCDB PJ4 for proper connection and correct as necessary    copyir.com 5 Check the connector between PS201-SCDB PJ6 for proper connection and correct as necessary    copyir.com 6 Check the connector between SCDB PJ2-PRCB CN43 for proper connection and correct as necessary    copyir.com 7 PS201 I/O check, sensor check SCDB PJ6-3 (ON) 25-P    copyir.com 8 M201 operation check SCDB PJ4-1 to 4 26-P    copyir.com 9 Replace SCDB    copyir.com 10 Replace PRCB    copyir.com
C6104    Back side cleaning home sensor abnormality (initial)
<When DF-701 is installed> • The CIS cleaning sensor (PS7) does not change from H to L even after the lapse of a given period of time after the home position detecting operation is started at the initial operation    copyir.com • The CIS cleaning sensor (PS7) does not change from L to H even after the lapse of a given period of time after the home position detecting operation is started at the initial operation    copyir.com    1 Check if the opening and closing guide is firmly closed    copyir.com 2 Check the connector between M5-DFCB J9 for proper connection, and correct as necessary    copyir.com 3 Check the connector of M5 for proper drive coupling, and correct as necessary    copyir.com 4 Check the connector between PS7-DFCB J13 for proper connection, and correct as necessary    copyir.com 5 PS7 I/O check, sensor check DRCB J13-3 (ON) DF-701 1-G    copyir.com 6 M5 operation check DRCB J9-1 to 4 DF-701 6-G    copyir.com 7 Replace M5    copyir.com 8 Replace DFCB    copyir.com
C6105    Back side cleaning home sensor abnormality (normal)
<When DF-701 is installed> At the time of operation other than the initial operation, the CIS cleaning sensor (PS7) error is detected    copyir.com    1 Check if the opening and closing guide is firmly closed    copyir.com 2 Check the connector between M5-DFCB J9 for proper connection, and correct as necessary    copyir.com 3 Check the connector of M5 for proper drive coupling, and correct as necessary    copyir.com 4 Check the connector between PS7-DFCB J13 for proper connection, and correct as necessary    copyir.com 5 PS7 I/O check, sensor check DRCB J13-3 (ON) DF-701 1-G    copyir.com 6 M5 operation check DRCB J9-1 to 4 DF-701 6-G    copyir.com 7 Replace M5    copyir.com 8 Replace DFCB    copyir.com
C6704    Image input time out
Image data is not input from the scanner to the MFP board (MFPB)    copyir.com    1 Select [Service Mode] – [State Confirmation] – [Memory/HDD Adj    copyir.com] – [Memory Bus Check] – [Scanner – Memory], and conduct the memory bus function    copyir.com 2 Check the connectors between scanner section and MFPB for proper connection and correct as necessary    copyir.com 3 Replace MFPB    copyir.com 4 Replace CCDB    copyir.com
C6751    CCD clamp/gain adjustment failure
• The adjustment value is 0 or 255 during a CCD clamp adjustment    copyir.com • The peak value of the output data is 64 or less during a CCD gain adjustment    copyir.com    1 Check the connector between CCDB PJ3-MFPB PJ01 for proper connection and correct as necessary    copyir.com 2 Check for possible extraneous light and correct as necessary    copyir.com 3 Clean the lens, mirrors, CCD surface, and shading sheet if dirty    copyir.com 4 Correct reflective mirror of the scanner if faulty, or change scanner mirror    copyir.com 5 Replace CCDB    copyir.com 6 Replace MFPB    copyir.com
C6752    ASIC clock input error (front side)
When starting the machine, verification on reading and writing the predetermined value for image processing ASIC on CCD board (CCDB) was conducted, and verification failure was detected    copyir.com    1 Correct the harness connection of CCDB if faulty    copyir.com 2 Replace CCDB    copyir.com 3 Replace MFPB    copyir.com
C6753    ASIC clock input error (back side)
<When DF-701 is installed> When starting the machine, verification on reading and writing the predetermined value for image processing ASIC on dual scan image processing board (DSIPB) was conducted, and verification failure was detected    copyir.com    1 Correct the harness connection between DF and DSIPB if faulty    copyir.com 2 Correct the harness connection between DSIPB and MFPB if faulty    copyir.com 3 Replace CIS    copyir.com 4 Replace DSIPB    copyir.com 5 Replace MFPB    copyir.com
C6754    CIS clamp adjustment failure
<When DF-701 is installed> After the gain adjustment is performed at the start-up, the CIS clamp adjustment value is too high or too low    copyir.com    1 Correct the harness connection between CIS and DSIPB if faulty    copyir.com 2 Correct the harness connection between CIS and CISPU if faulty    copyir.com 3 Check for possible extraneous light and correct as necessary    copyir.com 4 Clean the back side reading glass and the shading sheet if dirty    copyir.com 5 Replace CIS    copyir.com 6 Replace DSIPB    copyir.com 7 Replace CISPU    copyir.com 8 Replace MFPB    copyir.com
C6755    CIS gain adjustment failure
<When DF-701 is installed> After the gain adjustment is performed at the start-up, the peak value of the output data is lower than a given value    copyir.com    1 Correct the harness connection between CIS and DSIPB if faulty    copyir.com 2 Correct the harness connection between CIS and CISPU if faulty    copyir.com 3 Check for possible extraneous light and correct as necessary    copyir.com 4 Clean the back side reading glass and the shading sheet if dirty    copyir.com 5 Replace CIS    copyir.com 6 Replace DSIPB    copyir.com 7 Replace CISPU    copyir.com 8 Replace MFPB    copyir.com
C6756    CCD power-supply voltage malfunction
Power is not supplied to CCD after the lapse of a given period of time after the main power switch or sub power key is turned ON or the machine recovers from the sleep mode    copyir.com    1 Correct the harness connection between CCDB and SCDB if faulty    copyir.com 2 Correct the harness connection between SCDB and DCPU if faulty    copyir.com 3 Replace CCDB    copyir.com 4 Replace SCDB    copyir.com 5 Replace DCPU    copyir.com
C6901    DSC board mount failure 1
When MFP detects that DSC board/1 (front side) is not properly installed    copyir.com    1 Correct the harness connection of DSCB/1 if faulty    copyir.com 2 Replace DSCB/1    copyir.com 3 Replace MFPB
C6902    DSC board bus check NG1-1
When DSC bus check (front side) detects an error    copyir.com    1 Correct the harness connection of DSCB/1 if faulty    copyir.com 2 Replace DSCB/1    copyir.com 3 Replace MFPB
C6903    DSC board bus check NG1-2
When DSC bus check (front side) detects an error    copyir.com    1 Correct the harness connection of DSCB/1 if faulty    copyir.com 2 Replace DSCB/1    copyir.com 3 Replace MFPB
C6911    DSC board mount failure 2
<When DF-701 is installed> When MFP detects that DSC board/2 (back side) is not properly installed    copyir.com    1 Correct the harness connection of DSCB/2 if faulty    copyir.com 2 Correct the harness connection of DSIPB if faulty    copyir.com 3 Replace DSCB/2    copyir.com 4 Replace DSIPB    copyir.com 5 Replace MFPB    copyir.com
C6912    DSC Bus check NG2-1
<When DF-701 is installed> When MFP detects that DSC board/2 (back side) is not properly installed    copyir.com    1 Correct the harness connection of DSCB/2 if faulty    copyir.com 2 Correct the harness connection of DSIPB if faulty    copyir.com 3 Replace DSCB/2    copyir.com 4 Replace DSIPB    copyir.com 5 Replace MFPB    copyir.com
C6913    DSC Bus check NG2-2
<When DF-701 is installed> When MFP detects that DSC board/2 (back side) is not properly installed    copyir.com    1 Correct the harness connection of DSCB/2 if faulty    copyir.com 2 Correct the harness connection of DSIPB if faulty    copyir.com 3 Replace DSCB/2    copyir.com 4 Replace DSIPB    copyir.com 5 Replace MFPB    copyir.com
C6F01    Scanner sequence trouble 1
The original transport interval becomes shorter than the predetermined value due to an original transport control error in original reading in DF    copyir.com    1 Correct the harness connection between main body and DF if faulty    copyir.com 2 Replace DFCB (DF-624/DF-701)    copyir.com 3 Replace MFPB    copyir.com
C8101    Before reading pressure welding alienation mechanism
<When DF-624 is installed> • During a pressure motion being performed, the document reading sensor (PS4) output does not change from H to L    copyir.com • During a retraction motion being performed, the document reading sensor (PS4) output does not change from L to H    copyir.com
<When DF-701 is installed> • During a pressure motion being performed, the document reading sensor (PS6) output does not change from H to L    copyir.com • During a retraction motion being performed, the document reading sensor (PS6) output does not change from L to H    copyir.com    When DF-624 is installed: 1 Check the connector between M5-DFCB J18 for proper connection and correct as necessary    copyir.com 2 Check the connector of M5 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS4-DFCB J10 for proper connection and correct as necessary    copyir.com 4 PS4 I/O check, sensor check DFCB J10-3 (ON) DF-624 2-G    copyir.com 5 M5 operation check DFCB J18-4 to 5 DF-624 2-G    copyir.com 6 Replace M5    copyir.com 7 FSCB F8 conduction check    copyir.com 8 Replace DFCB    copyir.com
When DF-701 is installed: 1 Check the connector between M4-DFCB J18 for proper connection and correct as necessary    copyir.com 2 Check the connector of M4 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS6-DFCB J10 for proper connection and correct as necessary    copyir.com 4 PS6 I/O check, sensor check DFCB J10-3 (ON) DF-701 2-G    copyir.com 5 M4 operation check DFCB J18-4 to 5 DF-701 1-G    copyir.com 6 Replace M4    copyir.com 7 FSCB F8 conduction check    copyir.com 8 Replace DFCB    copyir.com
C8107    Glass cleaning mechanism trouble
<When DF-624 is installed> The document reading glass cleaning sensor (PS12) is not turned ON after the set period of time has elapsed after the glass cleaning motor (M4) is turned ON    copyir.com
<When DF-701 is installed> The document reading glass cleaning sensor (PS13) is not turned ON after the set period of time has elapsed after the document reading glass cleaning motor (M6) is turned ON    copyir.com    When DF-624 is installed: 1 Check the connector between M4-DFCB J8 for proper connection and correct as necessary    copyir.com 2 Check the connector of M4 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS12-DFCB J15 for proper connection and correct as necessary    copyir.com 4 PS12 I/O check, sensor check DFCB J15-5 (ON) DF-624 3-G    copyir.com 5 M4 operation check DFCB J8-1 to 4 DF-624 1 to 2-B    copyir.com 6 Replace M4    copyir.com 7 Replace DFCB    copyir.com
When DF-701 is installed: 1 Check the connector between M6-DFCB J8 for proper connection and correct as necessary    copyir.com 2 Check the connector of M6 for proper drive coupling, and correct as necessary    copyir.com 3 Check the connector between PS13-DFCB J15 for proper connection and correct as necessary    copyir.com 4 PS13 I/O check, sensor check DFCB J15-5 (ON) DF-701 3-G    copyir.com 5 M6 operation check DFCB J8-1 to 4 DF-701 1-B    copyir.com 6 Replace M6    copyir.com 7 Replace DFCB    copyir.com
C8302    Cooling fan trouble
<When DF-624 is installed> <When DF-701 is installed> • The lock signal continues to detect H during a given time while the DF cooling fan motor (FM1) is spinning    copyir.com • The lock signal continues to detect L during a given time while the cooling fan (FM1) is during halts    copyir.com    When DF-624 is installed: 1 Check the connector between FM1-DFCB J16 for proper connection and correct as necessary    copyir.com 2 Check the fan for possible overload and correct as necessary    copyir.com 3 FM1 operation check DFCB J16-3 (ON) DF-624 3-B 4 Replace FM1    copyir.com 5 DFCB F6 conduction check    copyir.com 6 Replace DFCB    copyir.com
When DF-701 is installed: 1 Check the connector between FM1-DFCB J16 for proper connection and correct as necessary    copyir.com 2 Check the fan for possible overload and correct as necessary    copyir.com 3 FM1 operation check DFCB J16-3 (ON) DF-701 7-G    copyir.com 4 Replace FM1    copyir.com 5 DFCB F6 conduction check    copyir.com 6 Replace DFCB    copyir.com
C9401    Exposure LED lighting failure
The output from the CCD sensor is a predetermined value or less during CCD sensor gain adjustment    copyir.com    1 Check the connection between SCDB-LU201, and correct if necessary    copyir.com 2 Check the connector between SCDB PJ1-PRCB CN43 for proper connection and correct as necessary    copyir.com 3 Check the connector between CCDB PJ3-MFPB PJ01 for proper connection and correct as necessary    copyir.com 4 Replace the LED exposure unit    copyir.com 5 Replace CCDB    copyir.com 6 Replace SCDB    copyir.com 7 Replace PRCB    copyir.com 8 Replace MFPB    copyir.com
C9402    Exposure LED lighting abnormally
The average output value of the CCD sensor with the scanner at its standby position is a predetermined value or more at the end of a scan job    copyir.com    1 Check the connection between SCDB-LU201, and correct if necessary    copyir.com 2 Check the connector between SCDB PJ1-PRCB CN43 for proper connection and correct as necessary    copyir.com 3 Check the connector between CCDB PJ3-MFPB PJ01 for proper connection and correct as necessary    copyir.com 4 Replace the LED exposure unit    copyir.com 5 Replace CCDB    copyir.com 6 Replace SCDB    copyir.com 7 Replace PRCB    copyir.com 8 Replace MFPB    copyir.com
C9403    CIS LED lighting failure
<When DF-701 is installed> At the CIS gain adjustment, the machine detected that the output of the CIS LED is lower than the specified value    copyir.com    1 Correct the harness connection between CIS and DSIPB if faulty    copyir.com 2 Correct the harness connection between CIS and CISPU if faulty    copyir.com 3 Replace CIS    copyir.com 4 CISPU F1, F2 conduction check    copyir.com 5 Replace CISPU    copyir.com 6 Replace DSIPB    copyir.com 7 Replace MFPB    copyir.com
C9404    CIS LED lighting abnormally
<When DF-701 is installed> After a scan job is completed, the machine detected that the average output of the CIS LED is greater than the specified value    copyir.com    1 Correct the harness connection between CIS and DSIPB if faulty    copyir.com 2 Correct the harness connection between CIS and CISPU if faulty    copyir.com 3 Replace CIS    copyir.com 4 CISPU F1, F2 conduction check    copyir.com 5 Replace CISPU    copyir.com 6 Replace DSIPB    copyir.com 7 Replace MFPB    copyir.com
CA051    Standard controller configuration failure
The controller of the MFP board (MFPB) is faulty    copyir.com
CA052    Controller hardware error
A controller hardware error is detected in the network interface    copyir.com    1 Check to see if the following setting has been correctly made: [Service Mode] – [System 2] – [Image Controller Setting]    copyir.com If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more    copyir.com 2 Check the connectors of the MFPB for proper connection and correct as necessary    copyir.com 3 Replace MFPB    copyir.com
CA053    Controller start failure
A controller start failure is detected in the controller interface    copyir.com    1 Check to see if the following setting has been correctly made: [Service Mode] – [System 2] – [Image Controller Setting]    copyir.com If changing the setting, turn OFF the main power switch and turn it ON again after 10 seconds or more    copyir.com 2 Check the connectors of the MFPB for proper connection and correct as necessary    copyir.com 3 Replace MFPB    copyir.com
CB001     copyir.com    copyir.com    copyir.com CB119    FAX board error
CB120     copyir.com    copyir.com    copyir.com CB196    Controller error
CC001    Vendor connection failure
CC151     copyir.com    copyir.com    copyir.com CC165    ROM contents error
CD004     copyir.com    copyir.com    copyir.com CD047    Hard disk error  